DVVk-5F FLEX VENT INSTRUCTIONS (CONT’D)

9.  Apply high temperature sealant (1000°F min.) to the vent 

connections before securing with the band clamps provided. 

NotICE:

 the flue pipe end without the adapter must be 

installed to the Termination Cap.

10.  Apply sealant to the outside of the flue pipe adapter and 

connect to the flexible venting. Then insert the adapter into 

the fireplace flue. Secure flue adapter to the fireplace flue 

with a minimum of 2 screws provided. 

See Figure 56.

11.  Attach the Outer Vent pipe to the 8-inch diameter collar on 

the fireplace with the large band clamp provided. Sealant 

may be used on the outer vent connections.

12.  Check all vent connections for tightness. Make sure 

horizontal venting has the proper rise and combustible 

clearances required. Refer to venting charts in fireplace 

instruction manual.

8” DIAMETER FLEX

VENT PIPE

5” DIAMETER FLEX

FLUE PIPE

5” DIAMETER

FLUE ADAPTOR

COLLAR

8” DIAMETER

FIREPLACE

INLET COLLAR

Figure 56

Figure 57

Содержание Boulevard MULTIFUNCTION REMOTE DVLL48SP

Страница 1: ...line or other flammable vapors and liquids in the vicinity of this or any other appliance WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electrical switch do not use any phone in your building Leave the building immediately Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the...

Страница 2: ... Component Wiring Diagram 23 Installation 24 29 Vent System Identification 30 Venting Fireplace 31 32 Venting Horizontal 33 Venting Horizontal Termination 34 Top Vent Vertical Termination 35 Vertical Termination 36 37 Dvvk 5F Flex Vent Instructions 38 39 Framing And Finishing 40 41 Liner Installation 42 Glass Placement 43 Multifunction Remote Operating Instructions 44 51 Control System Troubleshoo...

Страница 3: ...page 29 o _____________________ Venting installed locked secured in place with correct clearance o _____________________ Firestops installed o _____________________ Exterior wall roof flashing installed and sealed o _____________________ Terminations installed and sealed pages 34 36 o _____________________ Light unit and test venting before enclosing the fireplace o _____________________ ELECTRICA...

Страница 4: ...s engaged in and is responsible for a the installation or replacement of gas piping or b the connection installation repair or servicing of equipment who is experienced in such work familiar with all precautions required and has complied with all the requirements of the authority having jurisdiction Commonwealth of Massachusetts The installation must be made by a licensed plumber or gas fitter in ...

Страница 5: ...tes a hazardous situation which if not avoided could result in death or serious injury CAUTION Indicates a hazardous situation which if not avoided could result in minor or moderate injury NOTICE Addresses practices not related to personal injury ____________________________________________________ This direct vent gas fireplace and its components are tested and safe when installed in accordance w...

Страница 6: ...side standoff spacers and the fireplace can be secured to combustible framing with the framing brackets provided Planning the installation Determine where the fireplace will be located and what accessories will be installed Your location must allow for Venting either vertical or horizontal Choose a vent configuration See pages 34 36 and make sure the required access through attics and walls is not...

Страница 7: ...ction Box Cover 1 8 Duplex Receptacle 1 9 Flue Restrictor 1 10 Battery Box 1 11 Wire Harness 1 A 10 x 1 2 Screw 39 B 8 x 1 Self Drilling Screw 36 C Nailing Flange 8 For use in mounting non combustible board to standoffs Not shown See Parts Lists on page 50 for ordering replacement parts Do not order batteries bolts screws washers or nuts They can be purchased at your local hardware store 1 2 3 5 6...

Страница 8: ...s 1 16 Full Open Height without standoff inches 34 1 2 34 1 2 Width inches 61 1 4 61 1 4 Depth inches 20 1 2 20 1 2 Gas Inlet Shutoff Valve pipe 1 2 NPT 1 2 NPT NOTICE Air shutter settings are factory minimum settings Some venting configurations may require minor air shutter adjustments for optimum performance GAS SUPPLY PRESSURES Inches water column Gas Type Maximum Minimum Manifold Natural 14 4 ...

Страница 9: ...rcelain DVP48SLKR Black DVLL48SP Log and Rock Set LS60THF NA DVLL48SP SS Front Exterior Install DFED489SS NA DVLL48SP Crushed Glass Media Black DG1BKP Black DVLL48SP Crushed Glass Media Blue DG1BUC Blue DVLL48SP Crushed Glass Media Clear DG1CLF Clear DVLL48SP CONVERSION KITS Description Model Color Used On Conversion Kit Propane to Natural Gas 36435 NA DVLL48SP Conversion Kit Natural to Propane Ga...

Страница 10: ...he back side of the fireplace The front glass frame may be removed for service The rear glass frame is fixed in place Figure 1 PILOT TOWARDS RIGHT BEHIND THE BURNER FRONT BACK OUTDOOR KIT INSTALLATION SIDE RIGHT SIDE VIEW VENT BIASED TOWARDS BACK JUNCTION BOX GAS LINE BIASED TOWARDS FRONT BACK OUTDOOR KIT INSTALLATION SIDE FRONT BACK OUTDOOR KIT INSTALLATION SIDE VENT BIASED TOWARDS BACK JUNCTION ...

Страница 11: ...ffs 52 3 8 I Width from the left side of the box to the centerline of vent 30 5 8 J Depth from back of box to centerline of top vent 8 3 4 K Height from the bottom of the box to the gas line opening 14 5 8 L Depth from the front of the box to gas line opening 14 M Depth from rear of box to gas line opening 8 1 4 N Glass height 13 O Glass width 48 P Depth from front of box to centerline of vent 11 ...

Страница 12: ...LICATION 19 MIN 2 X 4 HEADER STAND OFF FINISHED WALL COMBUSTIBLE NON COMBUSTIBLE BOARD TOP FRAMING LEDGE BARRIER SCREEN GLASS FRONT NAILING FLANGE NON COMBUSTIBLE BOARD Figure 2 NOTICE Use only non combustible materials to finish the face of the fireplace NOTICE COMBUSTIBLE MATERIALS ALLOWED IN SHADED AREA Figure 3 Vent Pipe Clearance Notice Maintain 1 inch clearance around vertical vent pipe See ...

Страница 13: ... 4 H The height to the firebox standoffs 52 3 8 I Width from the left side of the box to the centerline of vent 30 5 8 J Depth from back of box to centerline of top vent 10 1 2 K Height from the bottom of the box to the gas line opening 14 5 8 L Depth from rear of box to gas line opening 14 M Depth from the front of the box to gas line opening 8 1 4 N Glass height 12 1 2 O Glass width 47 1 2 P Dep...

Страница 14: ...ure 11 CLEARANCES W DFED489SS 19 MIN 2 X 4 HEADER STAND OFF FINISHED WALL COMBUSTIBLE NON COMBUSTIBLE BOARD TOP FRAMING LEDGE BARRIER SCREEN GLASS FRONT NAILING FLANGE OUTDOOR KIT ON BACK SIDE OF UNIT NON COMBUSTIBLE BOARD Figure 7 NOTICE Use only non combustible materials to finish the face of the fireplace NOTICE COMBUSTIBLE MATERIALS ALLOWED IN SHADED AREA Figure 8 Vent Pipe Clearance Notice Ma...

Страница 15: ...ection Notice When installing this fireplace against an exterior wall insulate to applicable insulation codes Apeninsularoomdividerinstallationrequiresaminimumof6inches of clearance from the perpendicular wall to the front opening of the fireplace LOCATING FIREPLACE PENINSULA ROOM DIVIDER INSTALLATION ROOM DIVIDER INSTALLATION FLUSH EXTERIOR WALL INSTALLATION BUMP OUT EXTERIOR WALL INSTALLATION ...

Страница 16: ...hall be used to determine the allowable vertical and horizontal vent lengths The horizontal vent run refers to the total length of vent pipe from the flue collar of the fireplace to the face of the outer wall Venting termination shall not be recessed into wall or siding ATTENTION Vinyl Soffit Vinyl Ceiling Vinyl Overhang Disclaimer Clearances are to heat resistant material i e wood metal This does...

Страница 17: ...horizontal distance of 2 feet 61 cm from the center line of the terminal 24 in 61 cm 24 in 61 cm L Clearance above paved sidewalk or paved drive way located on public property 7 ft 2 13 m 7 ft 2 13 m E Clearance to unventilated soffit 12 in 30 cm 12 in 30 cm M Clearance under veranda porch deck or balcony 12 in 30 cm 12 in 30 cm F Clearance to outside corner 6 in 15 cm 6 in 15 cm 1 In accordance w...

Страница 18: ...st of a vertical length of pipe tee connected into the gas line that is capped on the bottom in which condensation and foreign particles may collect Figure 15 Installing a New Main Gas Shut Off Valve Check Local Code Each fireplace should have its own manual gas shut off valve located in the vicinity of the fireplace Where none exists or where its size or location is not adequate contact your loca...

Страница 19: ...ure to the valve from a minimum of 10 8 in w c 2 68 kPa for the purpose of input adjustment to a maximum of 14 0 in w c 3 484 kPa CAUTION If the test pressure exceeds 1 2 psig 14 in w c 3 5 kPa on the fireplace gas valve it will damage the valve and result in a hazardous condition GAS VALVE OUTLET PRESSURE TAP INLET PRESSURE TAP Figure 16 Gas Line Connection Remove the access panel from the right ...

Страница 20: ... or absorb onto or into walls masonry and other materials and fabrics in a room That will take some of the odorant out of the gas reducing its odor intensity Propane Gas may stratify in a closed area and the odor intensity couldvaryatdifferentlevels Becauseitisheavierthanair theremay be more odor at lower levels Always be sensitive to the slightest gas odor If you detect any odor treat it as a ser...

Страница 21: ... Edition A factory installed junction box is located on the lower right side of the fireplace Wiring must be fed to the junction box and attached to the receptacle that is provided Leave approximately 6in of wire in the junction box for connection Attach black wire to one side of the receptacle and white wire to opposite side of receptacle The ground wire should be attached to the green ground scr...

Страница 22: ...ausing strain on the harnesses See Figure 20 Run the extension wiring to the user interface wall box and connect the white connector to the remote receiver battery box Install the battery box into the wall outlet box and then install the white remote cover supplied with the provided screws ELECTRICAL CONNECTIONS CONT D WIRE GROMMET USER INTERFACE HARNESS AND BATTERY EXTENSION HARNESS CONNECT TO TH...

Страница 23: ...ing controls Wiring errors can cause improper and dangerous operation CAUTION Do not operate the fireplace with glass panel removed cracked or broken Replacement of the panel should be done by a licensed qualified service person WARNING Improper installation adjustment alteration service or maintenance can cause property damage personal injury or loss of life Installation and service must be perfo...

Страница 24: ... may vary with the type of building These instructions are not substitutes for the requirements of local building codes Check local building codes to determine the requirements to these steps To prevent cold air draft problems construct the chase in the manner of all outside walls The chase should not break the home s outside envelope Insulate the walls ceiling base plate and cantilever floor of t...

Страница 25: ...gure 23 NAILING FLANGES SECURED TO FRAMING EXTERIOR WALL SHOWN Figure 24 6 Attach three top framing brackets to the top front edge of the fireplace These brackets support the non combustible board above the fireplace Preset depth to suit facing material flush 1 2 inch or 3 4 inch set back depths See Figure 25 FLUSH MOUNTING 1 2 SET BACK MOUNTING 3 4 SET BACK MOUNTING FLUSH MOUNTING NOT APPLICABLE ...

Страница 26: ...s vented to the right or the left See Figure 27 For vertical vents install the header shields on the right or the left 3 Attach header shields to headers using eight 1 inch Phillips screws included See Figures 28 and 29 HEADER SHIELD HEADER SHIELD BRACKET Figure 26 VENT TO LEFT SIDE HEADER SHIELDS ON LEFT SIDE VENT TO RIGHT SIDE HEADER SHIELDS ON RIGHT SIDE Figure 27 Figure 28 ATTACH HEADER SHIELD...

Страница 27: ...37754 6 1019 Page 27 INSTALLATION CONT D Figure 29 HEADER SHIELDS ATTACHED TO HEADERS HEADER SHIELDS ATTACHED TO HEADERS ...

Страница 28: ...mbustible including wall anchors and tile spacers Materials that pass the ASTM E 136 test Standard Test Method for Behavior of Materials in a Vertical Tube Furnace at 750C are considered non combustible NOTICE Cold climate installation recommendation When installing this fireplace against a non insulated exterior wall it is recommended that the outer walls be insulated to conform to applicable ins...

Страница 29: ...AY OVERLAP THE OUTDOOR KIT UP TO 1 2 AWAY FROM THE KIT OPENING SEAL THE PERIMETER OF THE OUTDOOR KIT WITH 300 F 149 C SEALANT OVERLAP TOP EDGE OF NON COMBUSTIBLE BOARD WITH EXTERIOR WEATHER BARRIER SEAL THE INTERFACE BETWEEN THE OUTDOOR KIT AND THE FACING MATERIAL WITH AN EXTERIOR CAULK Finishing Exterior Wall With Outdoor Kit DFED489SS ...

Страница 30: ... Inc dealers DVVK 5RP Direct Vent Fireplace Vent Kit for Rear Vent 6 to 12 inch wall thickness Includes 58DVA 06 58DVA WT and 58DVAHC DVVK 5TP Direct Vent Fireplace Vent Kit for Top Vent Thru the wall 4 inch to 6 inch wall thickness Includes 58DVA E90 58DVA HC 58DVA 06 and 58DVA WT DVVK 5VP Direct Vent Fireplace Vent Kit Vertical Includes 58DVA VCH 58DVA SC and 58DVA F6 DVVK 5TS Top Vent Kit Horiz...

Страница 31: ... flange is 17 feet the vertical dimension from the floor of the fireplace to the center of the termination must not be less than 7 feet 6 inches Special Note For each 45 degree elbow installed in the horizontal run the length of the horizontal run MUST be reduced by 18 inches Reduce by 3 feet for every 90 degree elbow Example According to the chart the maximum horizontal vent length is 20 feet and...

Страница 32: ...tally terminated fireplaces Figures 37 to 40 show the location and recommended use of the flue restrictor Installation of restrictor before venting is attached See Figure 37 Figure 37 To install the restrictor after the venting is installed remove two screws from the end of the flue baffle and set aside Insert the restrictor up into the flue collar and position it as shown in Figures 38 and 39 The...

Страница 33: ... Minimum hole location dimensions for through the wall horizontal installations with 90 degree elbow and 12 inch rise off top of fireplace See Figure 44 on page 27 for permissible horizontal and vertical run dimensions Figure 40 ATTENTION Vinyl soffit vinyl ceiling vinyl overhang disclaimer Clearances are to heat resistant material i e wood metal This does not include vinyl Empire Comfort Systems ...

Страница 34: ... See Venting Graph 24 69 See Venting Graph 36 81 See Venting Graph 48 93 See Venting Graph Figure 43 Two 90 Degree Elbows Notice Subtract 3 feet from the total horizontal measurement for each 90 degree elbow Subtract 1 1 2 feet from the total horizontal measurement for each 45 degree elbow B SUBTRACT 3 FROM B DOESN T AFFECT ALLOWABLE B DIMENSION A TO BOTTOM OF UNIT EXAMPLE VENT RUNS INITIAL PIPE L...

Страница 35: ...24 120 10ft 204 17ft 36 120 10ft 204 17ft 48 120 10ft 204 17ft Figure 47 Three 90 Degree Elbows Notice Subtract 3 feet from the total horizontal measurement for each 90 elbow installed horizontally Subtract 1 1 2 feet from the total horizontal measurement for each 45 elbow installed horizontally B DOESN T AFFECT ALLOWABLE B DIMENSION SUBTRACT 3 FROM B FOR EACH A TO BOTTOM OF UNIT EXAMPLE VENT RUNS...

Страница 36: ...oor draft or down drafting In these cases increasing the vent height may solve this problem Installing the Vent System in a Chase A chase is a vertical box like structure built to enclose the gas fireplace and or its vent system Vertical vent runs on the outside of a building may be but are not required to be installed inside a chase CAUTION Treatment of firestop spacers and construction of the ch...

Страница 37: ... as rust spots or streaks and in extreme cases holes Replace damaged components should immediately 2 Remove the cap and shine a flashlight down the vent Remove any bird nests or other foreign material 3 Check for evidence of excessive condensate such as water droplets forming in the inner liner and subsequently dripping out at joints Condensate can cause corrosion of caps pipe and fittings It may ...

Страница 38: ...aintain equal distance between spring spacers Figure 54 5 FLEX VENT PIPE SPACER SPRING 8 FLEX VENT PIPE Figure 55 3 Attach a 6 inch piece of hard pipe to raise the connection point above the fireplace 4 Use existing 8 inch diameter inlet collar to attach outer vent pipe 5 Install the Wall Firestop Thimble assembly as required through the wall Refer to the venting charts on page___ to determine the...

Страница 39: ...replace flue Secure flue adapter to the fireplace flue with a minimum of 2 screws provided See Figure 56 11 Attach the Outer Vent pipe to the 8 inch diameter collar on the fireplace with the large band clamp provided Sealant may be used on the outer vent connections 12 Check all vent connections for tightness Make sure horizontal venting has the proper rise and combustible clearances required Refe...

Страница 40: ...ached to the vent pipe then secured with nails or screws to structural framing 48 PIPE STRAP Figure 58 Installing Firestops Firestops are required for safety whenever the vent system passes through a wall or a ceiling These firestops act as a firebreak heat shield and as a means to ensure minimum clearances Horizontal Firestops Horizontal runs require firestops on both sides of the wall Position t...

Страница 41: ...restop on the ceiling side of the framed hole See Figure 61 If the area above the ceiling is an attic position and secure the firestop on top of the framed hole See Figure 62 NOTICE Remove insulation from the framed area in the attic before installing the firestop and or vent pipes Figure 60 Figure 61 Figure 62 Finishing Finish the walls with the material of your choice Figure 12 shows the minimum...

Страница 42: ...ON NotICE A porcelain or ceramic fiber liner is required for this fireplace Refer to the installation instructions included with your liner for proper installation DVP48SLKR Porcelain Liner Kit Figure 63 DVP48SLG Fiber Liner Kit Figure 64 ...

Страница 43: ... and screens in a single layer Use enough crushed glass media to cover these areas 8 sq ft minimum See Figure 65 Figure 65 NotICE The flame appearance can be modified by varying the depth of glass media over the burner ports Assess the flame appearance before adding more media than is necessary to cover the burner Excessive glass media over the burner ports will cause sooting CAUTION Place glass m...

Страница 44: ...al bypass of the remote system CAUTION Property Damage Hazard Excessive heat can cause property damage The fireplace can stay lit for many hours Turn off the fireplace if it is not going to be attended for any length of time Always place the Transmitter where children can not reach it Figure 66 Figure 67 NOTICE Not all features called out in the diagram above are available on this fireplace NOTICE...

Страница 45: ...h a paper clip The IFC module will beep three times to indicate the IFC module is ready to synchronize with the transmitter within ten seconds See Figure 69 Figure 68 SWI BUTTON Figure 69 5 Push the On button The Receiver will beep four times to indicate the Transmitter s command is accepted and set to the code for that Transmitter The system is now initialized Figure 70 Temperature Indication Dis...

Страница 46: ...turn off the fireplace A single beep from the Receiver confirms reception of the command Remote Control Display Figure 73 Remote Flame Control The Proflame has six flame levels With the system on and the flame level at the maximum in the fireplace pressing the Down Arrow Button reduces the flame height one step at a time until the flame turns off The Up Arrow Button increases the flame height each...

Страница 47: ...accordance to the difference between the set point temperature and the actual room temperatures As the room temperature gets closer to the set point the Smart Function will modulate the flame down To activate this function press the Thermostat Button until the word SMART appears to the right of the temperature bulb graphic See Figure 80 To adjust the set temperature press the Up or Down Arrow Butt...

Страница 48: ...DVLL48SP OFF Figure 82 OFF Figure 83 Remote Dimmer Control Light Use the Mode Button Figure 67 to index to the light icon See Figures 84 and 85 Use the Up Down Arrow Buttons Figure 67 to adjust the output through six levels A single beep will confirm reception of each command OFF Figure 84 OFF Figure 85 ...

Страница 49: ...FF Figure 87 Remote Auxiliary Relay Control optional with this fireplace Use the Mode Button Figure 67 to index to the AUX icon See Figures 88 and 89 Pressing the Up Arrow Button will activate the outlet Pressing the Down Arrow Button will turn the outlet off A single beep will confirm reception of the command Figure 88 Figure 89 ...

Страница 50: ... to IPI A single beep will confirm the reception of the command OFF Figure 90 OFF Figure 91 Button Lock This function will lock the Buttons to avoid unsupervised operation To activate this function press the MODE and UP Buttons at the same time See Figure 92 To deactivate this function press the MODE and UP Buttons at the same time OFF Figure 92 Low Battery Power Detection Transmitter The life spa...

Страница 51: ... causes of lockout must be investigated under safe conditions by trained service personnel Using the Fireplace without a Remote Control The fireplace can be turned ON HI only and OFF with the wall switch The fireplace flame ON OFF is the only function that will operate no flame adjustment or light will work when using the wall switch The wall control switch should be turned OFF when the fireplace ...

Страница 52: ...or and pilot igniter See maintenance page 79 Pilot not grounded well Check ground connections Sensor Wire loose Check sensor wire terminals Gas pressure incorrect Adjust gas pressure Pilot Gas Line bent or kinked Replace pilot tube Faulty pilot Sensor bent Replace Pilot Faulty valve Replace Valve Burner takes too long to fully light Low gas pressure Check gas supply pressure Clogged or dirty carry...

Страница 53: ...r dirty burner ports Clean burner ports Faulty valve Replace valve High altitude Adjust orifice size for altitude Backfire of burner Blocked orifice Check orifice opening Clogged or dirty burner ports Clean burner ports Low gas pressure Check gas supply pressure Fireplace produces unwanted odors Vapors from paint hairspray glue etc Ventilate room until odor stops Do not use paint hairspray glue et...

Страница 54: ...ead the safety information above 2 Turn OFF electric power to the appliance 3 Turn gas shut off counterclockwise to ON position 4 Wait ten minutes to clear out any gas Then smell for gas including near the floor If you smell gas STOP Follow B in the safety information above on this label If you do not smell gas go to the next step 5 Turn ON electric power to the appliance 6 Using the remote contro...

Страница 55: ...37754 6 1019 Page 55 This page intentionally left blank ...

Страница 56: ...78 Venturi 22 37753 Orifice Bracket 23 P209 31 Orifice 24 R10915 Orifice Holder Flex Line 25 38577 Transformer With Bracket 26 R12451 LED Light Strip 27 38578 Glass Frame Stud Hardware Includes One 4 Are Required 28 R12391 Glass 5 9 16 X 48 29 37755 Glass Frame Stop Front 30 38575 Screen Frame Front 31 38576 Glass Frame 32 36450 Screen Frame Rear 33 38563 Header Shield 34 R7624 Air Shutter 35 NS R...

Страница 57: ...16 17 18 19 25 20 21 22 23 24 26 28 27 29 30 31 32 33 34 PARTS VIEW WARNING Failure to position the parts in accordance with these diagrams or failure to use only parts specifically approved with this fireplace may result in property damage or personal injury ...

Страница 58: ... single person It is recommended that two people remove the glass door LIFT UP TO RELEASE FROM TABS TABS 1 2 FIREPLACE FACE PIVOT OUT GLASS DOOR ASSEMBLY Figure 97 Wiring If any of the original wire supplied with this unit must be replaced it must be replace with 18 GA 150 C wire or its equivalent Gas Valve and Control Access Instructions CAUTION Sharp Edges Use gloves and eye protection when serv...

Страница 59: ... a qualified service technician 3 The gas control is a safety device It must be replaced in case of any physical damage such as bent terminals missing parts stripped threads or evidence of exposure to excessive heat Follow the operating instructions provided by the manufacturer of your appliance NOTICE It is normal for fireplaces fabricated of steel to give off some expansion and or contraction no...

Страница 60: ...ireplace and to replace any part of the control system and any gas control which has been under water In the event of a natural disaster tornado earthquake fire etc have a qualified technician inspect the fireplace for damage or potential gas leaks Repair or replace any damaged components before operating this fireplace Annual Inspection Have the fireplace inspected annually before use More freque...

Страница 61: ...intended for use with glass doors or equivalent shall emphasize that the appliance is not for use with glass doors 11 Where applicable provide a means by which the consumer can identify the barrier such as graphic representation clear description or reference marking WARNING CARBON MONOXIDE POISONING HAZARD Failure to follow the steps outlined below for each appliance connected to the venting syst...

Страница 62: ...37754 6 1019 Page 62 FIREPLACE SERVICE HISTORY Date Dealer Name Service Technician Name Service Performed Notes ...

Страница 63: ...rovisions shall comply with NFPA 720 and be ANSI UL 2034 listed and IAS certified 3 SIGNAGE A metal or plastic identification plate shall be permanently mounted to the exterior of the building at a minimum height of eight feet above grade directly in line with the exhaust vent termination for the horizontally vented gas fueled appliance or equipment The sign shall read in print size no less than 1...

Страница 64: ...and can be ordered by your Service Person or Dealer When ordering parts first obtain the Model Number and Serial Number from the rating plate on your equipment Then determine the Part Number from the list in this manual not the Index Number and the Description of each part from the illustration and part list Be sure to give all this information Fireplace Model Number Part Description Fireplace Ser...

Страница 65: ...ase Empire will repair or replace at Empire s option Duties Of The Owner The appliance must be installed by a qualified installer and operated in accordance with the instructions furnished with the appliance A bill of sale cancelled check or payment record should be kept to verify purchase date and establish warranty period Ready access to the appliance for service What Is Not Covered Damages that...

Страница 66: ...omfort com Empire Comfort Systems Inc Belleville IL If you have a general question about our products please e mail us at info empirecomfort com If you have a service or repair question please contact your dealer ...

Отзывы: