37754-6-1019
Page 39
DVVk-5F FLEX VENT INSTRUCTIONS (CONT’D)
9. Apply high temperature sealant (1000°F min.) to the vent
connections before securing with the band clamps provided.
NotICE:
the flue pipe end without the adapter must be
installed to the Termination Cap.
10. Apply sealant to the outside of the flue pipe adapter and
connect to the flexible venting. Then insert the adapter into
the fireplace flue. Secure flue adapter to the fireplace flue
with a minimum of 2 screws provided.
See Figure 56.
11. Attach the Outer Vent pipe to the 8-inch diameter collar on
the fireplace with the large band clamp provided. Sealant
may be used on the outer vent connections.
12. Check all vent connections for tightness. Make sure
horizontal venting has the proper rise and combustible
clearances required. Refer to venting charts in fireplace
instruction manual.
8” DIAMETER FLEX
VENT PIPE
5” DIAMETER FLEX
FLUE PIPE
5” DIAMETER
FLUE ADAPTOR
COLLAR
8” DIAMETER
FIREPLACE
INLET COLLAR
Figure 56
Figure 57