37754-6-1019
Page 54
FOR YOUR SAFETY READ BEFORE LIGHTING
A. This appliance must be lighted with the remote control.
When lighting the pilot, follow these instructions
exactly.
B. BEFORE LIGHTING, smell around the appliance area
for gas. Be sure to smell next to the floor because
some gas in heavier than air and will settle on the floor.
WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electrical switch.
• Do not use any phone in your building.
• Immediately call your gas supplier from a
neighbor's phone. Follow the gas supplier's
instructions. If you cannot reach your gas
supplier, call the fire department.
C. Use only the remote control to operate the valve.
Never use tools. If valve does not operate, don't try to
repair it, call a qualified service technician. Force or
attempted repair may result in a fire or explosion.
D. Do not use this appliance if any part has been
underwater. Immediately call a qualified service
technician to inspect the appliance and to replace any
part of the control system and any gas control which
has been underwater.
LIGHTING INSTRUCTIONS
1. Turn off all electric power to the appliance if service is
to be performed (if applicable).
2. Locate On/Off gas shut-off and turn clockwise to
OFF. Do not force.
LIGHTING INSTRUCTIONS
1. STOP! Read the safety information above.
2. Turn OFF electric power to the appliance.
3. Turn gas shut-off counterclockwise
to ON
position.
4. Wait ten minutes to clear out any gas. Then smell for
gas, including near the floor. If you smell gas, STOP!
Follow B in the safety information above on this label. If
you do not smell gas, go to the next step.
5. Turn ON electric power to the appliance.
6. Using the remote control, turn main flame to ON. Refer
to the Multifunction Remote Operating Instructions for
more information. If the pilot does not light within 60
seconds, stop and go back to Step 4.
7. Refer to remote control instructions for detailed
information, control features, and operation. Note:
Refer to Multifunction Remote operating instructions
for selection of continuous standing pilot mode or
intermittent pilot mode. If the pilot or burner does
not stay lit (in the continuous pilot mode), stop and
immediately call a qualified service technician or gas
supplier.
8. If the burner or pilot does not operate properly after
several tries, turn the gas control knob clockwise
to OFF and call your service technician or
gas supplier.
9. Operation of the gas valve, blower, and/or optional
light must be controlled by using the hand held remote
control. Refer to remote instructions for detailed
operation information.
WARNING
If you do not follow these instructions exactly, a fire or explosion may result causing property damage,
personal injury, or loss of life.
TO TURN OFF GAS TO APPLIANCE
GAS SHUT-OFF VALVE