![Emerson Rosemount 5408 Скачать руководство пользователя страница 60](http://html.mh-extra.com/html/emerson/rosemount-5408/rosemount-5408_reference-manual_103670060.webp)
3.7.5
Mount the welded version
Procedure
1. Mount the protection plates to flange/manhole cover. These plates protect the
internal surfaces of the flange ball from dust and sparks during welding.
%
$
A. Ø 3.94 ± 0.02 in. (Ø 100 ± 0.5 mm)
B. Max. 1.18 in. (30 mm)
2. Weld the flange ball.
Mechanical installation
Reference Manual
February 2020
00809-0100-4408
60
Reference Manual
Содержание Rosemount 5408