![Emerson Rosemount 5408 Скачать руководство пользователя страница 231](http://html.mh-extra.com/html/emerson/rosemount-5408/rosemount-5408_reference-manual_103670231.webp)
accumulation of electrostatic charge, it is necessary to clean the painted surfaces
with a damp cloth.
4. Appropriate cable, glands, and plugs need to be suitable for a temperature of 5 °C
greater than the maximum specified ambient temperature for location where
installed.
5. The Transmitter can be installed in the boundary wall between a level Ga and level
Gb location. In this configuration, the process connection is installed in Ga, while
the transmitter housing is installed in Gb. Refer to Control Drawing D7000002-885.
6. Cable entries must be used which maintain the ingress protection of the enclosure
to at least IP65. To maintain the ingress protection ratings, Covers and Sensor
Module to be fully tightened and PTFE tape or pipe dope is required for cable entries
and blanking plugs. See Instruction Manual on application requirements.
7. Using the box provided on the nameplate, the User shall permanently mark the
type of protection chosen for the specific installation. Once the type of protection
has been marked it shall not be changed.
8. The applicable temperature class, ambient temperature range and process
temperature range of the equipment is as follows:
Temperature class /
Maximum surface
temperature
Ambient temperature range
Process temperature range
IIC/ IIIC
T2/T250
-60 °C ≤ Ta ≤ 70 °C
-60 °C to 250 °C
T3/T200
-60 °C ≤ Ta ≤ 70 °C
-60 °C to 195 °C
T4/T135
-60 °C ≤ Ta ≤ 70 °C
-60 °C to 130 °C
T5/T100
-60 °C ≤ Ta ≤ 70 °C
-60 °C to 100 °C
T6/T85
-60 °C ≤ Ta ≤ 70 °C
-60 °C to 85 °C
B.15.2
IM Technical Regulations Customs Union (EAC) Intrinsic
Safety
Certificate
TC RU C-SE.AA87.B00756
Markings
0Ex ia IIC T4…T2 Ga X
Ga/Gb Ex ib IIC T4…T2 X
Ex ia IIIC T85°C …T250°C Da X
Tamb = -60 °C to +70 °C
Reference Manual
Product certifications
00809-0100-4408
February 2020
Rosemount 5408 and 5408:SIS Level Transmitters
231
Содержание Rosemount 5408
Страница 4: ...4 ...
Страница 8: ...Contents Reference Manual February 2020 00809 0100 4408 viii Reference Manual ...
Страница 10: ...Introduction Reference Manual February 2020 00809 0100 4408 10 Reference Manual ...
Страница 20: ...Transmitter overview Reference Manual February 2020 00809 0100 4408 20 Reference Manual ...
Страница 72: ...Mechanical installation Reference Manual February 2020 00809 0100 4408 72 Reference Manual ...
Страница 100: ...Operation Reference Manual February 2020 00809 0100 4408 100 Reference Manual ...
Страница 240: ...Product certifications Reference Manual February 2020 00809 0100 4408 240 Reference Manual ...
Страница 242: ...Product certifications Reference Manual February 2020 00809 0100 4408 242 Reference Manual ...
Страница 244: ...Product certifications Reference Manual February 2020 00809 0100 4408 244 Reference Manual ...
Страница 246: ...Product certifications Reference Manual February 2020 00809 0100 4408 246 Reference Manual ...
Страница 248: ...Product certifications Reference Manual February 2020 00809 0100 4408 248 Reference Manual ...