HE.14138_H © 09/2011
7
Abb. ähnlich / pic. similar
WORK
SERVICE
DON´T DO
General
safety rules
AHP 700-L
GB
Instruction Manual Battery-hydraulic Pump
authorised
copy
4.1 Operation of the unit
1. The female coupling of the hydraulic hose HSOEL2 (pic. 24.4) must be connected to the male coupling (pic. 1.5) of
the pump (pic. 16).
2. Select the right working unit for the intended application.
3. The selected working unit will be connected via the hydraulic hose HSOEL2 (pic. 24.4) with the pump (pic. 16)
Attention
Do not operate the pump without a working unit.
Attention
Before starting to operate the pump the oil level must be checked and possibly adjusted. (pic. 13 - 15).
4. Besides the built-in trigger (pic. 1.11) the following accessories can be connected:
• Remote control HTA4 (pic. 24.8)
• Safety foot switch incl. 4m cable FTA4 (pic. 25.2)
• Two hand safety control ZST4 (pic. 25.3)
• Bus bar tool centre and SBZ4
The pump recognises the various accessories through a special coding; the forward key (pic. 1.11) will be deactivated
accordingly.
5. The battery and possibly the spare battery will be plugged into the sockets (see pic. 12).
6. The pump is now ready to operate. The LCD display (pic. 1.9) is activated.
7. Select the program for the intended application by turning the selection knob (pic. 1.8) or the data function.
8. The working cycle (s. pic. 18ff .) is initiated by activating the advance function of the ‚forward and return keys‘
(pic. 1.11)
Attention
With the SBZ4 connected to pump and bus bar tool center the forward and return keys (Picture 1.11) are
deactivated.
Attention
The punching, hole making, crimping and cutting cycle can be stopped at any time by releasing or step-
ping down the actuator of the safety foot switch (pic. 25.2), resp. releasing the the two hand safety switch
(pic. 25.3).