7
emersonfans.com
Please contact 1-800-654-3545 for further assistance
U.L. Model No.: HF1160-2
HAIRPIN
CLIP
CLEVIS
PIN
MOTOR
YOKE
Figure 7
3.7
Align the clevis pin holes in the downrod with the holes in
the motor yoke. Install the clevis pin and secure with the
hairpin clip (Figure 7).
The clevis pin must go through the holes in the motor yoke.
It is critical that the clevis pin in the motor yoke is properly
installed and securely tightened.
Failure to verify that the pin is properly installed could result
in the fan falling (Figure 7).
It is critical that the clevis pin in the motor coupling is
properly installed. Failure to verify that the pin is properly
installed (as shown in Figure 6) could result in the fan
falling.
WARNING
!
MOTOR YOKE
5/16-18
SETSCREW (2)
ALLEN WRENCH
HANGER BALL/
DOWNROD ASSEMBLY
Figure 8
3.8
Reinstall the previously removed two 5/16-18 setscrews in
the motor yoke (Figure 8).
While pulling up on the hanger ball, securely tighten both
setscrews against the downrod using the allen wrench,
supplied.
It is critical that the setscrews are securely tightened.
Failure to verify that the setscrews are properly installed
(as shown in Figure 8) could result in the fan falling.
WARNING
!
3. Ceiling Fan Assembly
(Continued)
HANGER
BALL/ DOWNROD
ASSEMBLY
6 to 9
INCHES
3.9
The fan comes with black, green ground and white wires
that are 48-inches long.
Before installing the fan, measure up approximately
6 to 9-inches above top of hanger ball/downrod assembly
(Figure 9).
Cut off excess wires and strip back insulation 1/2-inch
from end of wires.
Figure 9
BP7272-4 HF1160.qxp_BP7272 9/10/15 9:44 PM Page 7
Содержание HF1160BQ02
Страница 22: ...Notes 22 U L Model No HF1160 2 BP7272 4 HF1160 qxp_BP7272 9 10 15 9 44 PM Page 22 ...
Страница 46: ...Notas 46 No de modelo U L HF1160 2 BP7272 4 HF1160 qxp_BP7272 9 10 15 9 44 PM Page 46 ...
Страница 70: ...Remarques 70 Modèle U L N HF1160 2 BP7272 4 HF1160 qxp_BP7272 9 10 15 9 44 PM Page 70 ...