6. Wall Control Installation
(Continued)
6.7
Connect the Wall Control BLACK wire to the 120 VAC
source hot BLACK wire using a new wire connector
(supplied) (Figure 25).
WALL CONTROL
BLACK WIRE
120 VAC HOT
BLACK WIRE
WALL
CONTROL
WIRE CONNECTOR
TO 120VAC
SOURCE HOT
TO FAN
MOTOR LOAD
Figure 25
6.8
Securely connect the GREEN ground wire from the Wall
Control to the supply ground wire (bare or green)
(Figure 26).
WALL CONTROL
GREEN GROUND
WIRE
WIRE
CONNECTOR
SUPPLY GREEN
GROUND WIRE
Figure 26
Check to see that all wire connections are tight, including
ground, and that no bare wire is visible at the wire
connectors, except for ground.
WARNING
!
TO 120VAC
SOURCE HOT
TO FAN
MOTOR LOAD
DO NOT CONNECT ANY WIRES FROM
WALL CONTROL TO THESE WHITE
NEUTRAL WIRES
Figure 27
6.9
NOTE: The WHITE neutral wires inside the electrical
box must be connected together for proper operation
of the wall control. NEVER connect the WHITE neutral
wires to the Wall Control (Figure 27).
Do not connect any neutral (WHITE) wire to this control.
Incorrect wiring WILL damage this control.