Figure 4-4 Surge suppression for analog and bipolar inputs and outputs
Surge suppression devices are available as rail-mounting modules, e.g. from Phoenix Contact:
Unipolar TT-UKK5-D/24 DC
Bipolar TT-UKK5-D/24 AC
4.7
Control terminal specification
Figure 4-5 Control terminals
Signal from plant
Signal to drive
0 V
0 V
2 x 15 V zener diode
e.g. 2xBZW50-15
1 (
I
on)
Digital input
Dual Function
Field economy select or enable
controller
(See Pr
81
)
Type
Single ended, negative logic (0 V
common for normal operation)
Voltage range
0 V to 24 V
Absolute maximum applied
voltage range
-18 V to 30 V
Load
2.4 mA at 0 V (sink)
Input threshold
High: 11 V, Low: 9 V
Update rate
4 ms
2 (0V)
0V common
Function
Common connection for all external
devices
3 (
I
ref)
Analog input
Function
Current demand input
Full scale voltage range
0 to 10 V
Absolute maximum voltage range
-18 V to 30 V
Input resistance
44 k
Ω
Resolution
10 bits
Sample period
4 ms
Iref
+10V If Va
Fail
11
1 2 3 4 5 6 7 8 9 10
0V
Ion