Table 7-3 Quick start commissioning / start up from defaults for Mentor II mode
Action
Detail
Before power up
Ensure:
•
Motor field is connected.
•
The Mentor II port on the FXMP25 is connected to the
Mentor II using a 10 way IDC to IDC ribbon.
•
The supply phases FXMP25 (L1 to L3) are in the same
phase as on the Mentor II (E1 to E3).
Power up the field
controller
Ensure:
•
The field controller displays:
•
If the field controller trips, see Chapter 9
Diagnostics
on
page 60.
Setting up the field
current feedback
scaling
•
Set parameter Pr
11
on FXMP25 to be the same value as
Pr
6.11
on Mentor II.
Select Mentor II
mode
To select Mentor II mode
•
Set Pr
78
(Field mode) = 2.H (2) for Mentor II mode, half
control (ensure Pr
6.22
on Mentor II is set accordingly).
•
Set Pr
78
(Field mode) = 2.F (3) for Mentor II mode, full
control (ensure Pr
6.22
on Mentor II is set accordingly).
•
Press the mode button to enter parameter view mode.
•
Press and hold the mode button for at least 2 seconds to
carry out a reset.
Setting up the field
controller
The Mentor II has taken control of the FXMP25. Setting up
should now be carried out using the Mentor II. Please refer to the
Mentor II User Guide Menu 6.
To setup flux OK
relay
Set Pr
25
and Pr
26
to the value required. Default values are set
to switch at 10 % current, the same as FXM5.
Содержание FXMP25
Страница 1: ...www controltechniques com User Guide Field Controller Part Number 0476 0009 03 Issue 3 FXMP25 ...
Страница 65: ......
Страница 66: ...0476 0009 03 ...