Issue Number: 3
Flux feedback after the current to flux converter, see motor saturation breakpoints in
Table 6-1
Quick look-up parameter table
on page 30.
When in current mode the flux demand from the field weakening voltage loop, subject to
the limits of Pr
68
and Pr
69
. When in voltage mode [Pr
75
= On (1)] the voltage demand
is subject to the limits of Pr
68
and Pr
69
.
The current feedback in amps.
Indicates percentage voltage demand. Negative value in full control indicates energy
absorption to force field down quicker.
0
°
= fully phased forward full volts applied to the field.
54
Flux feedback
Coding
Bit
FI
Txt
VM
DP
ND
US
RW
BU
PS
1
1
1
Range
±150.0 %
Update rate
Background write
55
Flux / voltage demand
Coding
Bit
FI
Txt
VM
DP
ND
US
RW
BU
PS
1
1
1
Range
±120.0 %
Update rate
Mains period / 6 ms
56
Field current feedback
Coding
Bit
FI
Txt
VM
DP
ND
US
RW
BU
PS
1
2
1
Range
±25.00 A
Update rate
Background write
57
Percentage voltage demand
Coding
Bit
FI
Txt
VM
DP
ND
US
RW
BU
PS
1
1
1
Range
±150.0 % (
0 to150 % in half control mode)
Update rate
Background write
58
Field firing angle
Coding
Bit
FI
Txt
VM
DP
ND
US
RW
BU
PS
1
1
1
Range
0.0 to 180.0
°
Update rate
Background write