![Emerson FloBoss 103 Скачать руководство пользователя страница 8](http://html.mh-extra.com/html/emerson/floboss-103/floboss-103_instruction-manual_102406008.webp)
FloBoss 103/104 Instruction Manual
1-2
General Information
Revised August-2017
Chapter 4
Input/Output
Provides information on the various I/O capabilities
of the FB100.
Chapter 5
Communications
Provides information on the communications
capabilities of the FB100.
Chapter 6
Dual-Variable Sensor
Provides information on the dual-variable sensor that
provides static and differential pressure inputs.
Chapter 7
Pulse Interface Module
Provides information on the pulse interface module
that provides pressure and pulse inputs.
Chapter 8
Calibration
Provides instructions on calibrating AI, RTD, and
DVS inputs.
Chapter 9
Troubleshooting
Provides information on diagnosing and correcting
problems for the FB100.
Glossary
Provides a general listing of acronyms and terms.
Index
Provides an alphabetic listing of items and topics
contained in this manual.
1.2 Product Overview
The FB100-Series—whether the FB103 or FB104—is a 32-bit
microprocessor-based electronic flow computer. The FB100
electronically measures, monitors, and manages gas flow for a single
meter run using orifice plate, rotary meter, or turbine meter techniques.
This economical flow computer reliably and accurately performs gas
flow calculations, temperature measurements, data archival, and remote
communications with an optional communications card installed.
Note
:
Any functional differences between the FB103 and FB104 are
noted in the text.
The FB100 performs minute, hourly (periodic), daily, and minimum /
maximum historical data archivals for standard history and a
configurable time interval archival for extended history. The FloBoss
103 is the perfect solution to electronically replace traditional paper
charting. The FB100 records the corrected gas flow across an orifice
plate or meter, stores the data, and has the ability to send the data to a
remote host.
The FB100 computes gas flow for both volume and energy. It provides
on-site functionality and supports remote monitoring, measurement,
data archival, communications, and control. The design of the FB100
allows you to configure specific applications, including those requiring
logic and sequencing control using a Function Sequence Table (FST).
Note
:
For further information on FSTs, refer to the
Function Sequence
Table (FST) User Manual
(part D301058X012).
Содержание FloBoss 103
Страница 6: ...FloBoss 103 104 Instruction Manual vi Revised August 2017 This page is intentionally left blank ...
Страница 84: ...FloBoss 103 104 Instruction Manual 8 10 Calibration Revised August 2017 This page is intentionally left blank ...
Страница 105: ...FloBoss 103 104 Instruction Manual Revised August 2017 I 5 This page is intentionally left blank ...