FloBoss 103/104 Instruction Manual
Revised August-2017
Power Connections
3-5
Solar arrays generate electrical power for the FB100 from solar
radiation. The size of solar panels required for a particular installation
depends on several factors, including the power consumption of all
devices connected to the solar array and the geographic location of the
installation.
The optional solar panel is adequate for support of API Chapter 21.1
compliant measurement and the retrieval of the historical logs once a
day using the internal communication methods.
3.4.1
Sizing the Solar Panel
To determine solar panel output requirements, first determine the solar
insolation for your geographic area. The map in
Figure 3-2
shows solar
insolation (in hours) for the United States during winter months. Call
your local sales representative for a map detailing your specific
geographic area.
Insolation (from map) = _____ hours
Next, calculate the amount of current required from the solar array per
day using the following equation. I
SF
is the system current requirement.
Refer to
Section 3.3
I
array
= [I
SF
(amps)
24 (hrs)]/Insolation (hrs) = _____ amps
Figure 3-2. Solar Insolation in Hours for the United States
Note
:
Refer to
http://www.solar4power.com/solar-power-global-
maps.html
for global solar insolation maps.
Содержание FloBoss 103
Страница 6: ...FloBoss 103 104 Instruction Manual vi Revised August 2017 This page is intentionally left blank ...
Страница 84: ...FloBoss 103 104 Instruction Manual 8 10 Calibration Revised August 2017 This page is intentionally left blank ...
Страница 105: ...FloBoss 103 104 Instruction Manual Revised August 2017 I 5 This page is intentionally left blank ...