DVC6000 Digital Valve Controllers
vi
1
2
3
4
5
A
B
C
D
E
F
G
H
I
6
Field Communicator Menu Tree for
Instrument Level AC
Online
1 Setup
2 Display
Calibrate
1 Analog In Calib
2 Auto Travel Calib
3 Man Travel Calib
4 Restore Factory Settings
5 Calib Loc
6 Relay Adjust
7 Tvl Sensor Adjust
General
1 HART Tag
2 Message
3 Descriptor
4 Date
5 Valve Serial Num
6 Inst Serial Num
7 Polling Address
Auto Setup
1 Setup Wizard
2 Relay Adjust
3 Auto Travel Calib
Device Information
1 HART Univ Rev
2 Device Rev
3 Firmware Rev
4 Hardware Rev
5 Inst Level
6 Device ID
Setup
1 Basic Setup
2 Detailed Setup
3 Calibrate
Basic Setup
1 Auto Setup
2 Manual Setup
Detailed Setup
1 General
2 Measured Var
3 Response Control
4 Relay Type
Display
1 Device Information
2 DD Revision
HART Application
1 Offline
2 Online
3 Utility
4 HART Diagnostics
Manual Setup
1 Instrument Mode
2 Press & Actuator
3 Tuning & Calib
Response Control
1 Tvl/Press Select
2 Tvl Tuning
3 Integral Settings
4 Press Tuning
5 Pressure Control
6 Input Char
Notes:
1‐1‐1 indicates fast‐key sequence to reach menu
This menu is available by pressing the left
arrow key from the previous menu.
1‐1
1‐1‐1
1‐1‐2
1‐2
1‐2‐1
1‐2‐3
2
1‐3
2‐1
1
1
Press & Actuator
1 Tvl/Press Select
2 Pressure Units
3 Max Supply Press
4 Actuator Style
5 Feedback Conn
6 Tvl Sensor Motion
7 Valve Style
8 Zero Pwr Cond
Tuning & Calib
1 Tvl Tuning Set
2 Press Tuning Set
3 Relay Adjust
4 Auto Travel Calib
1‐1‐2‐2
1‐1‐2‐3
1
Measured Var
1 Analog In Units
2 Input Range Hi
3 Input Range Lo
4 Pressure Units
1‐2‐2
Tvl Tuning
1 Tvl Tuning Set
2 Tvl Integ Enab
3 Tvl Integ Gain
1‐2‐3‐3
Press Tuning
1 Press Tuning Set
2 Press Integ Enab
3 Press Integ Gain
1‐2‐3‐4
1‐2‐3‐2
Integral Settings
1 Integ DeadZ
2 Integ Limit
Tvl Tuning Set
1 Tvl Tuning Set
2 Tvl Prop Gain
3 Tvl Velocity Gain
4 Tvl MLFB Gain
Tvl Tuning Set
1 Tvl Tuning Set
2 Tvl Prop Gain
3 Tvl Velocity Gain
4 Tvl MLFB Gain
Pressure Control
1 Press Range Hi
2 Press Range Lo
Press Tuning Set
1 Press Tuning Set
2 Press Prop Gain
3 Press MLFB Gain
Press Tuning Set
1 Press Tuning Set
2 Press Prop Gain
3 Press MLFB Gain
1‐1‐2‐3‐1
1‐1‐2‐3‐2
1-2-3-5
1‐2‐3‐2‐1
1‐2‐3‐4‐1
Hot Key
1 Instrument Mode
2 Protection
Setup
1 Basic Setup
2 Detailed Setup
3 Calibrate
Содержание Fisher FIELDVUE DVC6000
Страница 2: ......
Страница 22: ...DVC6000 Digital Valve Controllers September 2013 1 12 1 ...
Страница 82: ...DVC6000 Digital Valve Controllers September 2013 4 22 4 ...
Страница 94: ...DVC6000 Digital Valve Controllers September 2013 5 12 5 ...
Страница 139: ...Loop Schematics Nameplates September 2013 B 1 B B Appendix B Loop Schematics Nameplates B ...
Страница 161: ......