DVC6000 Digital Valve Controllers
September 2013
4-8
Table 4-5. Actuator Information for Initial Setup
Actuator
Manufacturer
Actuator
Model
Actuator Size
Actuator Style
Starting
Tuning
Set
Feedback
Connection
Travel Sensor Motion
Relay A or C
Relay B
Fisher
585C & 585CR
25
50
60
68, 80
100, 130
Piston Dbl w/ or
w/o Spring. See
actuator instruction
manual and
nameplate.
E
I
J
L
M
SStem-Standard
for travels up to
4 inches. SStem-
Roller for longer
travels
Depends upon pneumatic connections.
See description for Travel Sensor
Motion
657
30
34, 40
45, 50
46, 60, 70, 76, &
80-100
Spring &
Diaphragm
H
K
L
M
SStem-Standard
Clockwise
Counterclockwise
667
30
34, 40
45, 50
46, 60, 70, 76, &
80-100
Spring &
Diaphragm
H
K
L
M
SStem-Standard
Counterclockwise
Clockwise
1051 & 1052
20, 30
33
40
60, 70
Spring &
Diaphragm
H
I
K
M
Rotary
Clockwise
Counterclockwise
1061
30
40
60
68, 80, 100, 130
Piston Dbl w/o
Spring
J
K
L
M
Rotary
Depends upon pneumatic connections.
See description for Travel Sensor
Motion
1066SR
20
27, 75
Piston Sgl w/Spring
G
L
Rotary
Depends upon mounting style, see
actuator instruction manual and
2052
1
2
3
Spring &
Diaphragm
H
J
M
Rotary
Clockwise
Counterclockwise
3024C
30, 30E
34, 34E, 40, 40E
45, 45E
Spring &
Diaphragm
E
H
K
SStem-Standard
For P
o
operating
mode (air opens),
Counterclockwise
For P
s
operating
mode (air closes),
Clockwise
For P
o
operating
mode (air opens),
Clockwise
For P
s
operating
mode (air closes),
Counterclockwise
GX
225
Spring &
Diaphragm
X
(1)
SStem-Standard
Air to
750
K
Open
Close
1200
M
Counterclockwise
Clockwise
Baumann
Air to Extend
16
32
570
Spring &
Diaphragm
C
E
H
SStem-Standard
Clockwise
Counterclockwise
Air to Retract
Counterclockwise
Clockwise
Rotary
10
25
54
E
H
J
Rotary
Specify
1. X = Expert Tuning. Proportional Gain = 4.2; Velocity Gain = 3.0; Minor Loop Feedback Gain = 18.0
Table 4-6. Travel Sensor Motion Selections for the FIELDVUE
DVC6030 on a Fisher 1066SR Actuator
Mounting Style
Travel Sensor Motion
Relay A or C
Relay B
A
Clockwise
Counterclockwise
B
Counterclockwise
Clockwise
C
Counterclockwise
Clockwise
D
Clockwise
Counterclockwise
Integral Enable—Yes or No. Enable the
pressure integral setting to improve static performance
by correcting for error that exists between the
pressure target and actual pressure. Pressure Integral
Control is disabled by default.
Integral Gain—Pressure Integral Gain (also
called reset) is the gain factor applied to the time
integral of the error signal between desired and actual
pressure. Changing this parameter will also change
the tuning set to Expert.
4
Содержание Fisher FIELDVUE DVC6000
Страница 2: ......
Страница 22: ...DVC6000 Digital Valve Controllers September 2013 1 12 1 ...
Страница 82: ...DVC6000 Digital Valve Controllers September 2013 4 22 4 ...
Страница 94: ...DVC6000 Digital Valve Controllers September 2013 5 12 5 ...
Страница 139: ...Loop Schematics Nameplates September 2013 B 1 B B Appendix B Loop Schematics Nameplates B ...
Страница 161: ......