![Emerson Fisher 4660 Скачать руководство пользователя страница 20](http://html.mh-extra.com/html/emerson/fisher-4660/fisher-4660_instruction-manual_102283020.webp)
Instruction Manual
D200163X012
4660 Pressure Pilot
June 2017
20
7. Refer to the alignment of the nozzle beam procedure in the Operating Information section.
8. Replace the case cover, and attach it with the case cover screw.
9. Reset the high and/or low set points according to the procedures presented in the Operating Information section.
Low or High Set Point Assembly Replacement
Obtain the set point assembly listed in the parts kit section, then perform one or the other of the following procedures.
Pilots Without Set Point Indication
Note
New locking wedges (key 71) must be installed when performing this procedure. Refer to the parts list section and obtain the
correct quantity. Two are required for low or high versions. Four are required for high‐low versions.
1. Perform steps 1 through 4 of the Bourdon tube/flapper assembly replacement procedure.
2. Remove the knob (key 67) by loosening the knob set screw and pulling it away from the front plate (key 74).
3. Remove the locking disc (key 69) and the locking nut (key 70).
4. Remove the screws (key 68) and the switch point assembly.
5. Remove the locking wedges (key 71).
6. Install the new set point assembly and tighten the screws.
7. Install new locking wedges over the set point stem.
8. Apply lubricant (key 81) to the locking nut threads and install it finger‐tight.
9. Tighten the locking nut to 5.6 N
m (50 lbf
in) of torque. Back the nut out one‐quarter turn.
10. Re‐tighten the locking nut to 1.1 N
m (10 lbf
in) of torque.
11. Install the knob on the stem and tighten the set screws. Attempt to rotate the knob. If the knob rotates, repeat
steps 9 and 10.
12. Loosen the set screws and remove the knob.
13. Repeat steps 1 through 12 if both set point assemblies are to be replaced on a high‐low version of the pilot.
14. Install the front plate and the panel mounting plate (if required).
15. Install the locking disc(s) with the tab(s) as close to 90 degrees to the right of vertical as possible.
16. If the locking disc(s) cannot be installed as described in step 15, install the tab(s) between vertical and 90 degrees,
rather than beyond the 90 degree position.
17. Perform steps 6 through 11 of the Bourdon tube/flapper assembly replacement procedure.
Pilots With Set Point Indication
1. Perform steps 1 through 4 of the Bourdon tube/flapper assembly replacement procedure.
2. Remove the set point indication module by loosening the set screws that attach the module to the set point
assembly stem, and pulling it away from the front plate (key 74).
3. Remove the screws (key 68) and the set point assembly.
4. Install the new set point assembly and tighten the screws.