![Emerson Fisher 4660 Скачать руководство пользователя страница 13](http://html.mh-extra.com/html/emerson/fisher-4660/fisher-4660_instruction-manual_102283013.webp)
Instruction Manual
D200163X012
4660 Pressure Pilot
June 2017
13
3. Slowly turn the low set point knob (key 67) clockwise until the low set point is obtained. The low set point is
obtained when the output pressure of the pilot has changed from full output to zero.
4. Lock the locking disc (key 69).
Alternate Set Point Adjustment Procedure
This procedure may be used to closely approximate the desired high and low set points when no external pressure
source is available to simulate process pressure. If the pilot does not have the optional output indicator (key 88),
provide a means of indicating the output pressure. Refer to figure 5.
Figure 5. Set Point Adjustment Detail
DOTS
BUTTON
LOCKING DISC
POINTER
THUMBWHEEL
LOW SET POINT
INDICATION
LOCKING ARM
HIGH SET POINT
INDICATION
WITHOUT SET POINT INDICATION
WITH SET POINT INDICATION
48A3549‐F
39A1578‐A
A3300‐1
Refer to the appropriate procedure below.
Note
Make sure that the first six steps of the Preliminary Adjustments procedure found on page 11 have been completed before
proceeding.
High‐Low Construction
1. Refer to the WARNING at the beginning of the Operating Information section. Make sure the Bourdon tube contains
no pressure.
2. Connect supply pressure to the pilot.
WARNING
Before continuing on with step 3, read this Warning:
Natural gas, if used as the supply medium, will seep from the unit into the surrounding atmosphere when the SUPPLY TEST
button is pushed. Personal injury or property damage may result from fire or explosion if preventative measures are not
taken, such as adequate ventilation and the removal of any ignition sources.
3. Turn on the supply pressure. To check that the supply pressure is on, press the SUPPLY TEST button in the cleanout
assembly (key 54) until a flow sound is heard.