Digitax ST User Guide
197
Issue: 5
*If a tunE through tunE7 trip occurs, then after the drive is reset the drive cannot be made to run unless it is disabled via the Safe Torque Off input
(terminal 31), drive enable parameter (Pr
6.15
) or the control word (Pr
6.42
and Pr
6.43
).
Table 14-2 Serial communications look-up table
The trips can be grouped into the following categories. It should be noted that a trip can only occur when the drive is not tripped or is already tripped
but with a trip with a lower priority number.
UP udF
Onboard PLC program un-defined trip
97
Check program
UP uSEr
Onboard PLC program requested a trip
96
Check program
UV
DC bus under voltage threshold reached
1
Check AC supply voltage level
Drive voltage rating (Vac) Under voltage threshold (Vdc) UV reset voltage (Vdc)
200 175 215
400 330 425
Trip
Diagnosis
No.
Trip
No.
Trip
No.
Trip
1
UV
90
UP div0
181
C.Rdo
2
OV
91
UP PAr
182
C.Err
3
OI.AC
92
UP ro
183
C.dAt
4
OI.br
93
UP So
184
C.FULL
5
PS
94
UP ovr
185
C.Acc
6
Et
95
UP OFL
186
C.rtg
7
O.SPd
96
UP uSEr
187
C.TyP
8
PS.10V
97
UP udF
188
C.cPr
9
PS.24V
98
UP ACC
189
EnC1
10
br.th
99
t099
190
EnC2
11
tunE1
100
Reserved
191
EnC3
12
tunE2
101
t101
192
EnC4
13
tunE3
102
Reserved
193
EnC5
14
tunE4
103
Reserved
194
EnC6
15
tunE5
104
Reserved
195
EnC7
16
tunE6
105
Reserved
196
EnC8
17
tunE7
106
Reserved
197
EnC9
18
tunE
107
Reserved
198
EnC10
19
It.br
108
Reserved
199
dESt
20
It.AC
109
Reserved
200
SL1.HF
21
O.ht1
110
Reserved
201
SL1.tO
22
Reserved
111
Reserved
202
SL1.Er
23
Reserved
112 to 160
t112 to t160
203
SL1.nF
24
th
161
Enc11
204
SL1.dF
25
thS
162
Enc12
205
SL2.HF
26
O.Ld1
163
Enc13
206
SL2.tO
27
O.ht3
164
Enc14
207
SL2.Er
28
cL2
165
Enc15
208
SL2.nF
29
cL3
166
Enc16
209
SL2.dF
30
SCL
167
Enc17
210
SL3.HF
31
EEF
168 to 171
t168 to t171
211
SL3.tO
32
PH
172
C.SL1
212
SL3.Er
33
rS
173
C.SL2
213
SL3.nF
34
PAd
174
C.SL3
214
SL3.dF
35
CL.bit
175
C.Prod
215
SL.rtd
36
SAVE.Er
176
EnP.Er
216
t216
37
PSAVE.Er
177
C.boot
217 to 232
HF17 to HF232
38
t038
178
C.bUSY
39
Reserved
179
C.Chg
40 to 89
t040 to t089
180
C.OPtn