192
Digitax ST User Guide
Issue: 5
SLX.Er
Solutions Module slot X trip: Solutions Module in slot X or Digitax ST Plus/Indexer has detected a fault
202,207,212
Automation (Applications) module category
Check value in Pr
17.50
. The following table lists the possible error codes for the Digitax ST Plus and Digitax ST Indexer. See the
Diagnostics
section in the SM-Applications Modules and Motion Processors manual for more information.
Trip
Diagnosis
Error Code
Trip Description
39
User program stack overflow
40
Unknown error - please contact supplier
41
Parameter does not exist
42
Attempt to write to a read-only parameter
43
Attempt to read from a write-only parameter
44
Parameter value out of range
45
Invalid synchronisation modes
46
Unused
47
Synchronisation lost with CTSync Master
48
RS485 not in user mode
49
Invalid RS485 configuration
50
Maths error - divide by zero or overflow
51
Array index out of range
52
Control word user trip
53
DPL program incompatible with target
54
DPL task overrun
55
Unused
56
Invalid timer unit configuration
57
Function block does not exist
58
Flash PLC Storage corrupt
59
Drive rejected application module as Sync master
60
CTNet hardware failure. Please contact your supplier
61
CTNet invalid configuration
62
CTNet invalid baud-rate
63
CTNet invalid node ID
64
Digital Output overload
65
Invalid function block parameter(s)
66
User heap too large
67
RAM file does not exist or a non-RAM file id has been specified
68
The RAM file specified is not associated to an array
69
Failed to update drive parameter database cache in Flash memory
70
User program downloaded while drive enabled
71
Failed to change drive mode
72
Invalid CTNet buffer operation
73
Fast parameter initialisation failure
74
Over-temperature
75
Hardware unavailable
76
Module type cannot be resolved. Module is not recognized.
77
Inter-Solutions Module comms error with module in slot 1
78
Inter-Solutions Module comms error with module in slot 2
79
Inter-Solutions Module comms error with module in slot 3
80
Inter-Solutions Module comms error with module unknown slot
81
APC internal error
82
Communications to drive faulty