1.4
Liquid capacity reference tables
Table 1-5: Normal flow range
Meter
size
Normal flow range
Minimum linear
Maximum linear
GPM
BPH
BPD
M
3
PH
GPM
BPH
BPD
M
3
PH
3"
55
79
1,886
12.5
650
929
22,286
148
4"
85
121
2,914
19.3
1,250
1,786
42,857
284
6"
240
343
8,229
55
2,900
4,143
99,429
659
8"
475
679
16,286
108
5,200
7,429
178,286 1,181
10"
800
1,143
27,429
182
8,000
11,429
274,286 1,817
12"
1,330
1,900
45,600
302
12,000
17,143
411,429 2,725
16"
2,140
3,057
73,371
486
18,000
25,714
617,143 4,088
18"
2,860
4,086
98,057
650
24,100
34,429
826,286 5,474
20"
3,500
5,000
120,000 795
29,500
42,143
1,011,42
9
6,700
24"
4,700
6,714
161,143 1,067
40,000
57,143
1,371,42
9
9,085
Notes
:
1. Stated specifications are based on water at 60°F, with a specific gravity of 1.0 and a
viscosity of 1.0 centistokes.
2. Meters should be adequately protected from pressure pulsations and excessive
surges.
3. Generally, the PT Turbine should not be used in continuous service from the normal
maximum to the extended maximum flow rates. Consult Daniel Measurement
engineers for proper sizing and consideration.
4. All specifications are subject to change without notice as part of a continuing
program of product improvement.
5. Bi-directional meters have a linear flow range as stated in one direction of flow. The
minimum linear flow rate in the reverse direction is 20% of its normal maximum
linear flow rate.
Table 1-6: Extended flow range
Meter
size
Minimum extended flow range
Maximum extended flow range
GPM
BPH
BPD
M
3
PH
GPM
BPH
BPD
M
3
PH
3"
36
51
1,234
8.18
800
1,143
27,429
182
4"
55
79
1,886
12.5
1,500
2,143
51,429
341
6"
156
223
5,349
35.4
3,600
5,143
123,429 818
Dimensions and specifications
Installation and maintenance instructions
October 2019
3-9008-011
18
Daniel “PT” Liquid Turbine Meters
Содержание Daniel PT
Страница 2: ...2 ...
Страница 10: ...Contents Installation and maintenance instructions October 2019 3 9008 011 x Daniel PT Liquid Turbine Meters ...
Страница 12: ...Plan Installation and maintenance instructions October 2019 3 9008 011 12 Daniel PT Liquid Turbine Meters ...
Страница 24: ...Install Installation and maintenance instructions October 2019 3 9008 011 24 Daniel PT Liquid Turbine Meters ...
Страница 32: ...Operate Installation and maintenance instructions October 2019 3 9008 011 32 Daniel PT Liquid Turbine Meters ...
Страница 38: ...Maintain Installation and maintenance instructions October 2019 3 9008 011 38 Daniel PT Liquid Turbine Meters ...
Страница 55: ...Installation and maintenance instructions 3 9008 011 October 2019 Installation and maintenance instructions 55 ...