Viscosity
High viscosities will reduce flow range of meter. Consult Daniel Measurement engineers.
Pickup Coil
Nominal open circuit peak to peak voltage output:
BLADE
RIMMED
Minimum flow
4.0v
5.0v
Maximum flow
0.3v
0.1v
Table 1-2: Materials of construction
Item
Standard
Optional
Meter Body
304SS
316SS
Flanges (Slip on)
Carbon Steel
304SS or 316SS
Suspension
304SS
316SS
Rotor Blades (Rim Type)
304SS
316SS
Rotor Blades (Blade Type)*
430SS
Nickel 200*
Sleeve Bearings
Cemented Tungsten
Carbide
†
Journal Bearings
Cemented Tungsten
Carbide
†
Rotor Hub
1"-6"
430SS
316SS or 304SS
8"-12"
430SS
430SS and 7075AL
16"-24"
430SS and 7075AL
†
Rotor Rim
2"-4"
316SS
†
6"-24"
304SS
316SS
Rim Buttons
Hi Mu 80
†
Cones
304SS
316SS
Shaft
17-4 PH Heat Treated Stainless Steel
*
Recommended for salt water service; blade type meters with 316SS body, 316SS suspension,
316SS cones and Nickel 200 blades.
†
No option available.
Note
Consult Daniel engineers for unique applications.
Dimensions and specifications
Installation and maintenance instructions
October 2019
3-9008-011
16
Daniel “PT” Liquid Turbine Meters
Содержание Daniel PT
Страница 2: ...2 ...
Страница 10: ...Contents Installation and maintenance instructions October 2019 3 9008 011 x Daniel PT Liquid Turbine Meters ...
Страница 12: ...Plan Installation and maintenance instructions October 2019 3 9008 011 12 Daniel PT Liquid Turbine Meters ...
Страница 24: ...Install Installation and maintenance instructions October 2019 3 9008 011 24 Daniel PT Liquid Turbine Meters ...
Страница 32: ...Operate Installation and maintenance instructions October 2019 3 9008 011 32 Daniel PT Liquid Turbine Meters ...
Страница 38: ...Maintain Installation and maintenance instructions October 2019 3 9008 011 38 Daniel PT Liquid Turbine Meters ...
Страница 55: ...Installation and maintenance instructions 3 9008 011 October 2019 Installation and maintenance instructions 55 ...