5
Disassembly and assembly
instructions
5.1
3" through 24" PT Meter disassembly
Procedure
1. To remove preamplifier housing, unscrew collar nut on the quick connect union, lift
preamplifier housing, unscrew and disconnect cable connector from pickup coil.
Figure 5-1: Step 1
2. To remove pickup coil, unscrew from coil boss.
Note
Preamplifier housing and pickup coil need not be removed for internal meter
disassembly.
Installation and maintenance instructions
Disassembly and assembly instructions
3-9008-011
October 2019
Installation and maintenance instructions