Figure 2-10: Transducer cabling conduit
A. Rigid and flexible conduit for routing cables from transducers to Acquisition Module
B. Pipe strut clamp and channel assembly securing electronics to 2 inch vertical pole or
horizontal rail
C. Acquisition Module to transducer connections
D. 3818 LNG meter body with shrouds
E. Customer supplied vertical pole (2 inch pipe). May be horizontal rail. Must be securely
installed and rigid.
The process temperature must not exceed the operating temperature range of the LT-07
transducers. These transducers have an operating range from -196° C (-321° F) to +60° C
(+140° F).
Mechanical Installation
Installation manual
May 2019
3-9000-771
40
3818 LNG Liquid Ultrasonic Meter