3. NEVER attempt to lift the meter using only one sling around the meter. Always use
two slings wrapped around each end of the body as shown below. A choker style
sling is recommended.
Figure 2-8: Correct sling attachment with spreader bar
4. Visually inspect the slings prior to use for any signs of abrasion or other damage.
Refer to the sling manufacturer's procedures for proper inspection of the particular
sling you are using.
5. Only use slings with ratings that exceed the weight to be lifted. Reference your
company's standards for safety factors that must be included when calculating the
load rating.
6. Provide support for the transmitter electronics assemblies during lifting operations.
7. Once the lifting operation is complete, attach and secure the electronics to the pipe
stand or other rigid structure using the mounting bracket bolts.
CAUTION
CRUSHING HAZARD
Lifting the meter without supporting the transmitter enclosures may cause the
electronics to fall and cause personal injury or electronics damage.
Mechanical Installation
Installation manual
May 2019
3-9000-771
38
3818 LNG Liquid Ultrasonic Meter
Содержание Daniel 3818
Страница 2: ...2 ...
Страница 10: ...Contents Installation manual May 2019 3 9000 771 x 3818 LNG Liquid Ultrasonic Meter ...
Страница 26: ...Introduction Installation manual May 2019 3 9000 771 26 3818 LNG Liquid Ultrasonic Meter ...
Страница 60: ...Electrical Installation Installation manual May 2019 3 9000 771 60 3818 LNG Liquid Ultrasonic Meter ...
Страница 82: ......
Страница 83: ......
Страница 84: ......
Страница 85: ......
Страница 86: ...Engineering Drawings Installation manual May 2019 3 9000 771 82 3818 LNG Liquid Ultrasonic Meter ...