Use ethernet cable (Daniel P/N 1-360-01-596) to connect the PC to the meter.
Table 3-3: Ethernet cable to PC communication
Ethernet communication
Wire color
CPU
White w/Orange Stripe
TX+
Orange w/White Stripe
TX -
White w/Green Stripe
RX+
Green w/White Stripe
RX -
A DIN 41612 48-pin connector is the interface from the CPU Module to the Backplane
Board (male end located on the back of the Backplane Board).
Serial connections
Use serial cable (Daniel P/N 3-2500-401) to connect to a PC running Daniel MeterLink. The
cable is designed for RS-232 communications which is the serial Port A default
configuration (see
field wiring diagram, Daniel Drawing DMC-004936). The
DB-9 end of the cable plugs directly into the PC running Daniel MeterLink. The three wires
on the other end of the cable connect to the CPU Module. The RED wire goes to RX, the
WHITE wire goes to TX, and the BLACK wire goes to COM for the RS-485/RS-232 treenails
(
When Belden wire No. 9940 or equivalent is used, the maximum cable length for RS-232
communications at 9600 bps is 88.3 meters (250 ft.) and the maximum cable length for
RS-485 communication at 57600 bps is 600 meters (1970 ft.).
Port A supports a special override mode which forces the port to use known
communication values (19200 baud, address 32, RS-232). Note that the protocol is auto-
detected. This mode is expected to be used during meter commissioning (to establish
initial communication) and in the event that the user cannot communicate with the meter
(possibly due to an inadvertent communication configuration change). Alternately, when
using Daniel MeterLink
™
with an Ethernet port, use Ethernet cable (Daniel P/N
1-360-01-596) to connect the PC.
Installation manual
Electrical Installation
3-9000-771
May 2019
Installation manual
49
Содержание Daniel 3818
Страница 2: ...2 ...
Страница 10: ...Contents Installation manual May 2019 3 9000 771 x 3818 LNG Liquid Ultrasonic Meter ...
Страница 26: ...Introduction Installation manual May 2019 3 9000 771 26 3818 LNG Liquid Ultrasonic Meter ...
Страница 60: ...Electrical Installation Installation manual May 2019 3 9000 771 60 3818 LNG Liquid Ultrasonic Meter ...
Страница 82: ......
Страница 83: ......
Страница 84: ......
Страница 85: ......
Страница 86: ...Engineering Drawings Installation manual May 2019 3 9000 771 82 3818 LNG Liquid Ultrasonic Meter ...