Operation User
Manual
October 2015
QCL-MAN-CT2211-Aerosol-Leak-Detection-System-Rev F
Operation
24
5.1.10
Line Speed screen
This page shows the line speed of the conveyor.
Figure
5-10
below shows the Line Speed screen.
Figure 5-10 Line Speed screen
A.
Encoder Description: describes the use of the encoder.
B.
Line Speed: is the one second average of the line speed.
C.
Encoder Scaling: is the ratio of pulses of the encoder to mm of travel on the production line.
It is used to convert the encoder count from pulses to distance.
D.
Encoder Count: is the total number of pulses on the encoder since the control system was
last switched on.
E.
Line speed graph: shows the speed of the production line for the last sixty seconds.
5.2
Errors
There are a number of errors that the control system monitors for that may occur
during the normal operation of the system. If the error status indicator in the bottom
right hand side of the screen or if the traffic light indicators change from green then
the control system has detected an error. Most errors are easily reset from the Error
Status screen of the control system. The errors that are active show as red lights on the
Error Status screen. The following errors are detectable by the control system:
5.2.1
Overall system healthy
The
overall system healthy
error checks the system parameters on boot. If this error
occurs, there will be an explanation of the reason in the message box at the bottom of
the screen. The most likely reason for this error is an incorrect parameter in a
configuration file or missing configuration file. There files can be reinstalled with the
assistance of Cascade Technologies Ltd.
E
D
C
B
A