User Manual
Operation
QCL-MAN -CT2211-Aerosol-Leak-Detection-System-Rev F
October 2015
Operation
17
5.1.3
Program Page
The programs used by the control system store the parameters required by the control
system that are variable between different can diameters and products.
See
Section 5.4: Control system programs
for a description of the creation and use of
programs.
Figure 5-3
below shows the Program Page:
Figure 5-3 Program Page screen
A.
Program Selector: this allows the operator to select from all the programs stored on the
control system.
B.
Config backup
: this allows the operator to create a backup of the configuration file on an
external USB drive.
C.
Program Description: this describes the program and when it should be used. This
information is entered by the user during the program creation process.
D.
Add program
button: allows the user to add a new program using the current programs
parameters as a starting point.
E.
Save changes
button: allows the user to save any changes made to the program, this button
is only shown when there are changes to be saved.
F.
Can Diameter: the diameter of the container to be used with this program.
B
C
A
D
E
F