QCL-MAN-CT2211-Aerosol-Leak-Detection-System-Rev F
Introduction
4
Figure 1-2 Aerosol leak detection system - blower configuration
A.
HMI
M. Input gate signal
B.
Leak detection system
2
N. Compressed air supply min 5 BAR, max 10 BAR
(customer supplied)
C.
AC supply voltage 110V/220V AC, 50-60 Hz
13A (customer supplied)
O. Phase controlled power
D.
Line status signals to customer
communications (running, waiting, error)
P. Encoder
E.
Encoder signal
Q. Output gate
F.
Rejected can signal
R. Reject.
G.
Output gate signal
S. Micro Leak detector
H.
Reject signal
T. Air status air control
I.
CT2211 communications (cat5)
U. Input gate
J.
CT2211 I/O and power
V. ATEX zone 2 disconnect switch
K.
Mirror cleaning signal
W. ATEX zone 2 rated blower
L.
Air status signal
X. Rejected can gate
Y. Reject bin (customer supplied)
2
The leak detection system components are: DC power supplies (+12V & 24V); system controlling PC with
Microsoft® Windows operating system; micro leak and control system software; national instruments digital I/O and
digital timing card; line driver and opto barrier circuitry; customer line PLC interface; circuit protection; AC power
control; and console thermal management and control.
A
B
C
D
E
F
G
H
I
J
K
L
M
N
O
P
Q
R
S
T
U
V
W
X
Y
Max cable run
Line direction
Micro leak control console
Out of zone
components
Rated components — zone 2