User Manual
Operation
QCL-MAN -CT2211-Aerosol-Leak-Detection-System-Rev F
October 2015
Operation
19
5.1.5
CT2211 Main Screen
All of the control system parameters relating to the leak detector are displayed on this
page. For all sensor related issues see the Leak Detector manual supplied separately.
Figure 5-5
below shows the Main Screen.
Figure 5-5 CT2211 Main Screen
A.
Graphs page
Button: navigates to the leak detector Graphs page.
B.
System Healthy
indicator: displays the health status of the leak detector.
C.
Laser Healthy
indicator: displays the health status of the laser used in the leak detector.
D.
Venturi Healthy
indicator: displays the health status of the air supply to the Venturi.
E.
IP
address Indicator: displays the IP address of the leak detector connected to the control
system.
F.
Input Gate position: is the position relative to the main input gate of the control system of
the input gate to the leak detector, which is typically located close to the air archway used
to sample gas into the leak detector from the conveyor.
G.
Output Gate position: is the position relative to the main input gate of the control system of
the output gate from the leak detector, which is typically located after the air archway used
to sample gas into the leak detector from the conveyor.
H.
Purge Frequency: is the time duration (in hours) between the required mirror purge
cleaning function. After this time durationn the system goes into warning for two hours
before going into an error state if the cleaning purge is not performed.
I.
Purge Length: is the time (in seconds) that the mirror cleaning purge is activated for.
J.
Mirror purge
button: activates the purge function, which should not be carried out when
there are cans in the system as the mirror purge function disrupts the normal operation of
the leak detector during the purge duration.
K.
CT2211 IN Counter: provides a running count of cans entering the detection zone since last
reset.
L.
CT2211 OUT Counter: provides a running count of cans exiting the detection zone since last
reset.
M.
CT2211 REJ Counter: provides a running count of cans rejected since last reset.
M
L
K
F
G
D
C
B
A
J
I
H
E