Operation
22
5.1.8
Optical Gates screen
The Optical Gates screen allows the user to see the output gate position and the bin
full time for the control system.
Figure
5-8
below shows the Optical Gates screen:
Figure 5-8 Optical Gates page
A.
Input Gate Position: displays the position in mm of the input gate of the system. This is
always
0
.
B.
Output Gate Position: displays the position in mm of the output gate of the system relative
to the input gate.
C.
Bin Full Time: is the time in seconds that the reject verification gate must be blocked for the
bin full error to be displayed.
D.
Last Output: monitors the canister position as it exits the leak detection system.
E.
Position Summary Chart: summarizes any deviations in the expected can position when
exiting the leak detection system.
F.
Position Summary Chart Reset: clears the Position summary chart.
F
E
D
B
C
A