10. The blue, black and white leads exiting the downrod

are 80-inches long. Before installing fan, measure
up approximately 6 to 9-inches above the
ball/downrod assembly. Cut off excess leads and
strip back insulation 1/2-inch from end of leads.

NOTE: If you are installing your fan with a SR330
Remote Control or SW350 Wall Control, Do Not
Cut Terminal Off of the Yellow Lead.
(See Section A.)

6. Install the setscrew (supplied in loose parts bag) in

the motor coupling and tighten using the 5/32"
setscrew wrench (supplied) (Figure 3B).

7. Screw two 1” threaded studs (provided) into the

motor (Figure 4B). Leave approximately 7/8” of the
stud extending above the motor. Slide the motor
cover over the downrod and rotate the cover until
the threaded studs protrude; install two knurled
knobs (supplied) to secure the cover.

NOTE: Make sure the red and brown leads are capped
with wire connectors. Make sure the red, brown, and
yellow wires and wire connectors are completely
inside motor coupling cover and not pinched between
the motor coupling cover and motor.

8. Position the ceiling cover over the downrod. Be

sure the cover is oriented correctly, with the large
opening at the top (Figure 5B).

9. Reinstall the hanger ball on the downrod as

follows. Route the motor leads through the hanger
ball and slide the hanger ball over the downrod
(Figure 5B). Install the pin through the holes at the
top of the downrod and slide the hanger ball up
the downrod, aligning the ball so the pin is
captured in the groove in the top of the hanger
ball. Pull the hanger ball up tight against the pin
and securely tighten the setscrew in the hanger
ball. A loose setscrew could create fan wobble.

DOWNROD

SETSCREW

Figure 3B

9

It is critical that the clevis pin in the motor coupling
is properly installed and the setscrew securely
tightened. Failure to verify that the pin and setscrew
are properly installed could result in the fan falling.

WARNING

!

It is critical that the pin in the hanger ball is properly
installed and the setscrew securely tightened.
Failure to verify that the pin and setscrew are
properly installed could result in the fan falling.

WARNING

!

7/8"

RED LEAD

WIRE
CONNECTORS

KNURLED KNOB

1" THREADED
STUD

MOTOR

MOTOR 
COUPLING
COVER

WIRE CONNECTOR

YELLOW LEADS

BROWN LEAD

Figure 4B

SETSCREW

DOWNROD

PIN

HANGER BALL

CEILING COVER

Figure 5B

11. Use three 10-32 x 3/8" pan head screws and flat

washers (supplied) to secure flange to blade
(Figure 6B). Repeat for the remaining four blades.

12. Use the 10 round recessed holes in the motor hub

marked with "5" and install the five blade assemblies
(ordered separately) in accordance with Step 13.

13. Attach one blade assembly to the motor hub using

two 10-32 x 5/8" oval head screws (supplied)
(Figure 7B). Do not tighten completely at this time.
Install remaining blade assemblies in the same
way. Gently snug all flange screws to the motor
hub, working around the hub in a clockwise
sequence. Next, securely tighten all flange screws,
again working in a clockwise sequence. Failure to
follow this procedure could result in fan wobble.
This completes the blade installation.

BLADE

BLADE
FLANGE

10-32 x 3/8"
PAN HEAD
SCREW (3)

FLAT WASHER (3)

Figure 6B

Содержание CROWN CF4500AB04

Страница 1: ... MO 63136 Include all model numbers shown on the product with your request To return the product to an authorized service center call 1 800 654 3545 for the address of the nearest authorized service center You will be responsible for all insurance freight or other transportation charges to our factory or authorized service center Your Emerson Air Comfort Ceiling Fan should be properly packed to av...

Страница 2: ...al Codes do not exist The ceiling fan must be grounded as a precaution against possible electrical shock Electrical installation should be made or approved by a licensed electrician 3 The outlet box and joist must be securely mounted an capable of reliably supporting a least 50 pounds Use only U L outlet boxes listed as acceptable for fan support and use the mounting screws provided with the outle...

Страница 3: ...sing Call Toll Free 1 800 654 3545 This product is designed to use only those parts supplied with this product and or any accessories designated specifically for use with this product by Emerson Company Substitution of parts or accessories not designated for use with this product by Emerson Company could result in personal injury or property damage WARNING WARNING Your new ceiling fan will require...

Страница 4: ... Choose the Section of Instructions from the List Below that Describes the Uplight Application You Wish to Achieve Begin Your Ceiling Fan Assembly with the Appropriate Section APPLICATIONS USE PAGE NO 1 Assembly Instructions for Installing Section A 5 the CF4800 or CF4500 Ceiling Fan with the Emerson SR330 Remote Control or the SW350 Wall Control 2 Assembly Instructions for Installing Section B 8 ...

Страница 5: ...d blue brown and yellow wires of the ceiling fan Figure 4A Wires must be connected color to color 7 Fold all wires from the downrod into the slot in the motor coupling slide the downrod down the wires and seat the downrod in the motor coupling All wires and wire connectors should be placed through the motor coupling slot beneath the downrod See Figure 5A 8 Align the clevis pin holes in the downrod...

Страница 6: ...LANGE 10 32 x 3 8 PAN HEAD SCREW 3 FLAT WASHER 3 Figure 8A 9 Install the setscrew supplied in the loose parts bag in the motor coupling and tighten using the 5 32 setscrew wrench supplied Figure 5A NOTE Make sure the unused black motor lead is capped with a wire connector Make sure all wires and wire connectors are completely inside motor coupling cover and not pinched between the motor coupling c...

Страница 7: ... outlet box Most outlet boxes commonly used for support of light fixtures are not acceptable for fan support and may need to be replaced Consult a qualified electrician if in doubt The outlet box must be securely anchored and capable of withstanding a load of at least 50 lbs WARNING WARNING Hanger bracket must seat firmly against outlet box If the outlet box is recessed remove wall board until bra...

Страница 8: ... installed to prevent the clevis pin from working loose Pull on the hanger ball to make sure the clevis pin is properly installed HANGER BALL DOWNROD CLEVIS PIN SETSCREW Figure 1B 8 21 Turn the receiver so that the flat side aligns with the open side of the hanger bracket Figure 13A Fold and position the wires into the space above the hanger ball and into the outlet box 22 Feed the wires and conne...

Страница 9: ...e groove in the top of the hanger ball Pull the hanger ball up tight against the pin and securely tighten the setscrew in the hanger ball A loose setscrew could create fan wobble DOWNROD SETSCREW Figure 3B 9 It is critical that the clevis pin in the motor coupling is properly installed and the setscrew securely tightened Failure to verify that the pin and setscrew are properly installed could resu...

Страница 10: ...O SCREWS SUPPLIED WITH OUTLET BOX HANGER BRACKET TAB OUTLET BOX OUTLET BOX HANGER BRACKET HANGER BALL DOWNROD ASSEMBLY NOTE CEILING COVER SUPPLY WIRES AND FAN WIRES OMITTED FOR CLARITY Figure 9B Figure 10B 10 10 32 x 5 8 OVAL HEAD SCREWS 2 PER BLADE ASSEMBLY Figure 7B To reduce the risk of personal injury do not bend the blade flange when installing the blade flanges balancing the blades or cleani...

Страница 11: ... possible fire or shock make sure that the electrical wires are completely inside the outlet box and not pinched between the ceiling cover and the ceiling WARNING Using Your Ceiling Fan 1 Restore electrical power to the outlet box by turning the electricity on at the main fuse box 2 When controlled by a wall switch check the operation of the fan by gently pulling on the 4 position speed control pu...

Страница 12: ...ews securing fan blade flanges to motor 3 Check to be sure screws which attach hub are loose the fan blade flanges to the motor hub are tight 4 Fan blade flanges not seated properly 4 Check to be sure the fan blade flanges seat firmly and uniformly to the surface of the motor hub If flanges are seated incorrectly loosen the flange screws and retighten according to Step 15 13 or 17 in Sections A or...

Страница 13: ...HOW TO ORDER REPAIR PARTS WHEN ORDERING REPAIR PARTS ALWAYS GIVE THE FOLLOWING INFORMATION NAME OF ITEM MODEL NUMBER THE PART NUMBER THE PART DESCRIPTION For repair parts phone 1 800 654 3545 6 13 1 2 3 16 14 15 7 10 20 19 9 21 22 8 24 18 17 5 4 23 27 12 11 29 30 25 26 31 18 28 TM 32 11 12 33 ...

Страница 14: ...4 762304 762304 Parts Bag containing 761629 761629 1 761629 761629 761629 761629 761629 1 761629 2 4 Pin Clevis 1 5 Clip Hairpin 1 11 Coupling 2 12 Pendant 2 14 Wire Connector 3 15 Wrench Setscrew 1 16 Stud Threaded 1 1 4 2 17 Lockwasher 2 18 Knob Knurled 4 19 Screw 10 32 x 5 8 11 20 Screw 8 32 x 3 8 2 21 Screw 10 32 x 3 8 16 22 Washer Flat 16 27 Setscrew 1 31 Stud Threaded 1 2 24 Auxiliary Capaci...

Страница 15: ...62304 762304 762304 Parts Bag containing 761629 1 761629 1 761629 1 761629 761629 1 761629 1 761629 761629 1 4 Pin Clevis 1 5 Clip Hairpin 1 11 Coupling 2 12 Pendant 2 14 Wire Connector 3 15 Wrench Setscrew 1 16 Stud Threaded 1 1 4 2 17 Lockwasher 2 18 Knob Knurled 4 19 Screw 10 32 x 5 8 11 20 Screw 8 32 x 3 8 2 21 Screw 10 32 x 3 8 16 22 Washer Flat 16 27 Setscrew 1 31 Stud Threaded 1 2 24 Auxili...

Страница 16: ...ip Hairpin 1 11 Coupling 2 12 Pendant 2 14 Wire Connector 3 15 Wrench Setscrew 1 16 Stud Threaded 1 1 4 2 17 Lockwasher 2 18 Knob Knurled 4 19 Screw 10 32 x 5 8 11 20 Screw 8 32 x 3 8 2 21 Screw 10 32 x 3 8 16 22 Washer Flat 16 27 Setscrew 1 31 Stud Threaded 1 2 24 Auxiliary Capacitor 762242 762242 762242 762242 762242 25 Cover Housing 760671 760671 15 760671 1 760671 14 760671 23 26 Harness 76145...

Отзывы: