background image

© VALLOX • We reserve the right to make changes without prior notification.

TECHNICAL SPECIFICA

TION

• 1.09.259E
• 22.7.2007
• CODE 3510
© VALLOX

VALLOX 75
VALLOX 75 VKL

CODE 3510

Models:

VALLOX 95
VALLOX 95 VKL

Technical specifications

• For dwelling-specific ventilation for detached houses,

terraced houses and blocks of flats

• Supply and extract air ventilation with heat recovery
• Silent operation
• Good filtering
• In-built heat recovery bypass for summer ventilation
• Versatile control options
• Handy ceiling mounting plate – for simple and quick

mounting

• Service switch as standard

All models are available as R and L models

Fans

105 W 

65 dm

3

/s

90 Pa

105 W 

75 dm

3

/s 130 Pa

180 W 

85 dm

3

/s

75 Pa

180 W 

95 dm

3

/s 130 Pa

VALLOX 75

Fans

VALLOX 95

Supply air
Extract air
Supply air
Extract air

Supply air
Extract air

Plate heat exchanger, efficiency approx. 60%
Summer / winter damper
Electric 500 W radiator or water radiator (VKL)
G 3 + F 7
G 3
36 kg
Door switch
Cooker hood PTX / PTXP, control centre 1992A/1992A EK
or remote monitoring control centre 1993A YK
230 V, IP 34

Heat recovery
Heat recovery bypass
Post-heating
Filters

Weight
Service switch
Power adjustment

Input power and data

Summary of Contents for 75

Page 1: ...Handy ceiling mounting plate for simple and quick mounting Service switch as standard All models are available as R and L models Fans 105 W 65 dm3 s 90 Pa 105 W 75 dm3 s 130 Pa 180 W 85 dm3 s 75 Pa 1...

Page 2: ...1 VALLOX 75 95 DIMENSIONS PERFORMANCE 2 2 Pressure loss in ducts Total pressure SFP Specific Fan Power guideline value 2 5 kw m3 s SFP Input power total W Air flow max dm3 s Dimensions and duct outlet...

Page 3: ...19 31 34 40 43 47 19 25 33 38 43 62 68 75 78 86 82 86 37 43 51 54 60 60 64 41 56 65 65 71 72 76 41 48 55 57 63 67 69 30 34 42 45 50 54 58 24 28 34 36 40 43 46 15 24 34 37 40 42 44 17 27 30 35 38 43 1...

Page 4: ...prevented and heat recovery bypass is activated REMOTE MONITORING CENTRE VALLOX 1993 A ON OFF switch Operating status data to remote monitoring Transformer with eight voltage options of which two one...

Page 5: ...unit starts automatically as soon as the risk of freezing has passed The threshold temperature of the risk of freezing can be set at the thermostat J of the water radiator Though VALLOX 75 95 VKL unit...

Page 6: ...front edge of the collar When detaching the damper take the same steps in the opposite order Self actuated one way dampers are only used in VKL model units B C Detaching of thermostat sensor from and...

Page 7: ...iator The overheat protector T2 of the radiator R is triggered and power supply to the heating unit is stopped if the temperature of the thermostat exceeds 80 C The overheat protector is reset manuall...

Page 8: ...ture of water radiator goes below the threshold value preventing the risk of freezing in the water radiator This also causes self actuated one way dampers SP to close preventing the flow of outdoor ai...

Page 9: ...230 V 160 V 120 V 70 V L N 90 V 135 V 180 V 1 5 X 1 5 S 2 3 PL 11 L 1 2 3 230 V 160 V 120 V 70 V L L 2 N 90 V 135 V 4 L2 180 V 1 2 3 PL 11 0 4 N L3 N VALLOX 75 95 3510 external electrical connection w...

Page 10: ...Wire colours m black r brown s blue T2 F1 F2 K TK m s s s s s m m m m m L N N 1 L T1 m m K r r N L m 1 m s L 1 s V W 2 3 3 X 1 5 S L 10 A N N 1 L N L 1 L L N L 3 2 N INTERNAL ELECTRICAL CONNECTION OF...

Page 11: ...NITORING VALLOX 75 95 control through remote monitoring with control centre 1993 YK 2A VALLOX 1993A YK 2A VALLOX 75 95 REMOTE MONITORING CONTROL CENTRE DISTRIBUTION PANEL OPERATING STATUS DATA OPERATI...

Page 12: ...e approximately 40 kg The ceiling mounting plate has to be fixed horizontally in order to ensure that the unit will be straight Installation Lift the unit straight upwards till the locking wings on th...

Page 13: ...s wall mounting accessories with the exception of screws The unit has to be mounted horizontally and vertically straight Wall construction Pay attention to the wall construction when mounting the unit...

Page 14: ...nted The delivery does not include a water seal nor the pipe and its components Examples of condensing water connections Yli 600 n 100 n 100 Suction air COLLECTOR condensing water goes to the cellar W...