![Emerson CROWN CF4500AB04 Скачать руководство пользователя страница 8](http://html.mh-extra.com/html/emerson/crown-cf4500ab04/crown-cf4500ab04_owners-manual_102838008.webp)
26. Screw in three 40-watt (maximum) candelabra
base lamps into the uplight sockets on top of the
fan housing assembly.
27. Connect the pendant and chain (supplied) to the
switch pull chain using the coupling (supplied).
SECTION B
Assembly Instructions
for Installing the CF4800 or
CF4500 Ceiling Fan to Control
the Built-in Uplight with the
Pull Chain in the Switch Cup
1. Position the fan motor and housing assembly in the
lower foam packing so that the top of the motor is
facing you.
2. Separate, untwist and unkink the four motor leads.
3. Obtain the hanger ball/downrod assembly and
remove the hanger ball by loosening the setscrew
in the hanger ball until the ball falls freely down the
downrod (Figure 1B). Remove the pin from the
downrod , then remove the hanger ball. Retain the
pin and hanger ball for reinstallation in Step 6.
4. Route the white, blue, and black motor leads through
the downrod. Fold the yellow wire into the slot in the
motor coupling, slide the downrod down the wires and
seat the downrod in the motor coupling (Figure 2B).
5. Align the clevis pin holes in the downrod with the
holes in the motor coupling. Install the clevis pin and
secure with the hairpin clip (Figure 2B). The clevis
pin must go through the holes in the motor coupling
and the holes in the downrod. Push the straight leg of
the hairpin clip through the hole near the end of the
clevis pin until the curved portion of the hairpin clip
snaps around the clevis pin. The hairpin clip must be
properly installed to prevent the clevis pin from
working loose. Pull on the hanger ball to make sure
the clevis pin is properly installed.
HANGER BALL
DOWNROD
CLEVIS PIN
SETSCREW
Figure 1B
8
21. Turn the receiver so that the flat side aligns with
the open side of the hanger bracket (Figure 13A).
Fold and position the wires into the space above
the hanger ball and into the outlet box.
22. Feed the wires and connectors around the
outside of the receiver, through the open side of
the hanger bracket, and into the outlet box. Slide
the receiver up and over the hanger bracket.
Remove the backing on the foam adhesive pads
and press the receiver against the ceiling.
HANGER
BRACKET
HANGER
BALL
CEILING
COVER
RECEIVER
FLAT SIDE
OPEN
SIDE
Figure 13A
23. Screw the two 1-1/4” threaded studs (provided)
into the tapped holes in the hanger bracket.
24. Lift the ceiling cover up to the threaded studs and
turn until studs protrude through the holes in the
ceiling cover (Figure 14A).
25. Secure the ceiling cover in place by sliding
lockwashers over the threaded studs and
installing the two knurled knobs (supplied).
(Figure 14A.) Tighten the knurled knobs securely
until the ceiling cover fits snugly against the
ceiling and the hole in the ceiling cover is clear of
the pipe.
1-1/4"
THREADED
STUD
LOCKWASHERS (2)
CEILING COVER
KNURLED KNOB
Figure 14A
To avoid possible fire or shock, make sure that the
electrical wires are completely inside the outlet box
and not pinched between the ceiling cover and the
ceiling.
WARNING
!
SETSCREW
CLEVIS PIN
MOTOR
COUPLING
DOWNROD
HAIRPIN
CLIP
MOTOR
COUPLING
HAIRPIN
CLIP
CLEVIS
PIN
DOWNROD
BROWN LEAD
RED LEAD
CLEVIS PIN
YELLOW LEAD
FROM UPLIGHT
YELLOW LEADS