c. Securely connect the blue wire from the

downrod to the supply red (hot) wire using wire
connector (supplied). After connections have
been made, turn leads upward and carefully
push leads into the outlet box, with the white
and green leads on one side of the outlet box
and the black, blue and yellow leads on the
other side of the outlet box.

17. Screw the two 1-1/4” threaded studs (provided)

into the tapped holes in the hanger bracket.

18. Lift the ceiling cover up to the threaded studs and

turn until studs protrude through the holes in the
ceiling cover (Figure 12B).

19. Secure the ceiling cover in place by sliding

lockwashers over the threaded studs and
installing the two knurled knobs (supplied).
(Figure 12B.) Tighten the knurled knobs securely
until the ceiling cover fits snugly against the
ceiling and the hole in the ceiling cover is clear of
the pipe.

20. Screw in three 40-watt (maximum) candelabra

base lamps into the uplight sockets on top of the
fan housing assembly.

21. Connect the pendant and chain (supplied) to the

switch pull chain using the coupling (supplied).

11

Check to see that all connections are tight, including
ground, and that no bare wire is visible at the wire
connectors, except for the ground wire. Do not
operate fan until blades are in place. Noise and fan
damage could result.

WARNING

!

BLACK

BLACK FAN WIRE

LISTED OUTLET BOX

LIGHT
CONTROL

GREEN WIRE
(GROUND) 
FROM 
HANGER 
BRACKET

TO 120 
VOLT
SUPPLY

WHITE

GROUND

GROUND

GREEN WIRE (GROUND)
FROM  HANGER BALL

LISTED WIRE CONNECTOR (4)

GROUND
WIRE

WHT.

EMERSON FAN CONTROL

BLACK
(HOT)

BLUE

RED

THREE - CONDUCTOR CABLE 
WITH GROUND BETWEEN 
CEILING AND WALL OUTLET 
BOXES

Figure 11B

1-1/4"
THREADED
STUD

LOCKWASHERS (2)

CEILING COVER

KNURLED KNOB

Figure 12B

To avoid possible fire or shock, make sure that the
electrical wires are completely inside the outlet box
and not pinched between the ceiling cover and the
ceiling.

WARNING

!

Using Your Ceiling Fan

1. Restore electrical power to the outlet box by turning

the electricity on at the main fuse box.

2. When controlled by a wall switch check the

operation of the fan by gently pulling on the 4-
position speed control pull chain switch. (This
switch has the longer pull chain.) The operating
sequence is as follows:

THREE-SPEED
1st Pull—HIGH
2nd Pull—Medium
3rd Pull—Low

4th Pull—OFF

3.When operated by an Emerson Remote Control,

check operation of fan and light in accordance with
the Remote Control Owner’s Manual.

4. If airflow is desired in opposite direction, turn your

fan off and wait for the blades to stop turning. Then
slide the reversing switch to the opposite position
and turn fan on again. The fan blades will turn in
the opposite direction and reverse the airflow.

Attaching Light Kit

To install an Emerson accessory light kit, remove the
three screws securing the switch cup assembly to the
fan, remove the switch cup assembly, and disconnect
the connector. Remove the screw plug from the
bottom of the switch cup and install the light kit in
accordance with the Emerson light kit Owner's
Manual.

SPEED
CONTROL
SWITCH

REVERSIBLE
SWITCH

TM

To avoid possible electrical shock, be sure electricity
is turned off at the main service box before wiring.

WARNING

!

Maintenance

IMPORTANT CARE INSTRUCTIONS

for your Ceiling Fan

Periodic cleaning of your new ceiling fan is the only
maintenance that is needed.

When cleaning, use only a soft brush or lint free cloth
to avoid scratching the finish.

Abrasive cleaning agents are not required and should
be avoided to prevent damage to finish.

Do not use water when cleaning your ceiling fan. It
could damage the motor or the blades and create the
possibility of an electrical shock.

WARNING

!

Содержание CROWN CF4500AB04

Страница 1: ... MO 63136 Include all model numbers shown on the product with your request To return the product to an authorized service center call 1 800 654 3545 for the address of the nearest authorized service center You will be responsible for all insurance freight or other transportation charges to our factory or authorized service center Your Emerson Air Comfort Ceiling Fan should be properly packed to av...

Страница 2: ...al Codes do not exist The ceiling fan must be grounded as a precaution against possible electrical shock Electrical installation should be made or approved by a licensed electrician 3 The outlet box and joist must be securely mounted an capable of reliably supporting a least 50 pounds Use only U L outlet boxes listed as acceptable for fan support and use the mounting screws provided with the outle...

Страница 3: ...sing Call Toll Free 1 800 654 3545 This product is designed to use only those parts supplied with this product and or any accessories designated specifically for use with this product by Emerson Company Substitution of parts or accessories not designated for use with this product by Emerson Company could result in personal injury or property damage WARNING WARNING Your new ceiling fan will require...

Страница 4: ... Choose the Section of Instructions from the List Below that Describes the Uplight Application You Wish to Achieve Begin Your Ceiling Fan Assembly with the Appropriate Section APPLICATIONS USE PAGE NO 1 Assembly Instructions for Installing Section A 5 the CF4800 or CF4500 Ceiling Fan with the Emerson SR330 Remote Control or the SW350 Wall Control 2 Assembly Instructions for Installing Section B 8 ...

Страница 5: ...d blue brown and yellow wires of the ceiling fan Figure 4A Wires must be connected color to color 7 Fold all wires from the downrod into the slot in the motor coupling slide the downrod down the wires and seat the downrod in the motor coupling All wires and wire connectors should be placed through the motor coupling slot beneath the downrod See Figure 5A 8 Align the clevis pin holes in the downrod...

Страница 6: ...LANGE 10 32 x 3 8 PAN HEAD SCREW 3 FLAT WASHER 3 Figure 8A 9 Install the setscrew supplied in the loose parts bag in the motor coupling and tighten using the 5 32 setscrew wrench supplied Figure 5A NOTE Make sure the unused black motor lead is capped with a wire connector Make sure all wires and wire connectors are completely inside motor coupling cover and not pinched between the motor coupling c...

Страница 7: ... outlet box Most outlet boxes commonly used for support of light fixtures are not acceptable for fan support and may need to be replaced Consult a qualified electrician if in doubt The outlet box must be securely anchored and capable of withstanding a load of at least 50 lbs WARNING WARNING Hanger bracket must seat firmly against outlet box If the outlet box is recessed remove wall board until bra...

Страница 8: ... installed to prevent the clevis pin from working loose Pull on the hanger ball to make sure the clevis pin is properly installed HANGER BALL DOWNROD CLEVIS PIN SETSCREW Figure 1B 8 21 Turn the receiver so that the flat side aligns with the open side of the hanger bracket Figure 13A Fold and position the wires into the space above the hanger ball and into the outlet box 22 Feed the wires and conne...

Страница 9: ...e groove in the top of the hanger ball Pull the hanger ball up tight against the pin and securely tighten the setscrew in the hanger ball A loose setscrew could create fan wobble DOWNROD SETSCREW Figure 3B 9 It is critical that the clevis pin in the motor coupling is properly installed and the setscrew securely tightened Failure to verify that the pin and setscrew are properly installed could resu...

Страница 10: ...O SCREWS SUPPLIED WITH OUTLET BOX HANGER BRACKET TAB OUTLET BOX OUTLET BOX HANGER BRACKET HANGER BALL DOWNROD ASSEMBLY NOTE CEILING COVER SUPPLY WIRES AND FAN WIRES OMITTED FOR CLARITY Figure 9B Figure 10B 10 10 32 x 5 8 OVAL HEAD SCREWS 2 PER BLADE ASSEMBLY Figure 7B To reduce the risk of personal injury do not bend the blade flange when installing the blade flanges balancing the blades or cleani...

Страница 11: ... possible fire or shock make sure that the electrical wires are completely inside the outlet box and not pinched between the ceiling cover and the ceiling WARNING Using Your Ceiling Fan 1 Restore electrical power to the outlet box by turning the electricity on at the main fuse box 2 When controlled by a wall switch check the operation of the fan by gently pulling on the 4 position speed control pu...

Страница 12: ...ews securing fan blade flanges to motor 3 Check to be sure screws which attach hub are loose the fan blade flanges to the motor hub are tight 4 Fan blade flanges not seated properly 4 Check to be sure the fan blade flanges seat firmly and uniformly to the surface of the motor hub If flanges are seated incorrectly loosen the flange screws and retighten according to Step 15 13 or 17 in Sections A or...

Страница 13: ...HOW TO ORDER REPAIR PARTS WHEN ORDERING REPAIR PARTS ALWAYS GIVE THE FOLLOWING INFORMATION NAME OF ITEM MODEL NUMBER THE PART NUMBER THE PART DESCRIPTION For repair parts phone 1 800 654 3545 6 13 1 2 3 16 14 15 7 10 20 19 9 21 22 8 24 18 17 5 4 23 27 12 11 29 30 25 26 31 18 28 TM 32 11 12 33 ...

Страница 14: ...4 762304 762304 Parts Bag containing 761629 761629 1 761629 761629 761629 761629 761629 1 761629 2 4 Pin Clevis 1 5 Clip Hairpin 1 11 Coupling 2 12 Pendant 2 14 Wire Connector 3 15 Wrench Setscrew 1 16 Stud Threaded 1 1 4 2 17 Lockwasher 2 18 Knob Knurled 4 19 Screw 10 32 x 5 8 11 20 Screw 8 32 x 3 8 2 21 Screw 10 32 x 3 8 16 22 Washer Flat 16 27 Setscrew 1 31 Stud Threaded 1 2 24 Auxiliary Capaci...

Страница 15: ...62304 762304 762304 Parts Bag containing 761629 1 761629 1 761629 1 761629 761629 1 761629 1 761629 761629 1 4 Pin Clevis 1 5 Clip Hairpin 1 11 Coupling 2 12 Pendant 2 14 Wire Connector 3 15 Wrench Setscrew 1 16 Stud Threaded 1 1 4 2 17 Lockwasher 2 18 Knob Knurled 4 19 Screw 10 32 x 5 8 11 20 Screw 8 32 x 3 8 2 21 Screw 10 32 x 3 8 16 22 Washer Flat 16 27 Setscrew 1 31 Stud Threaded 1 2 24 Auxili...

Страница 16: ...ip Hairpin 1 11 Coupling 2 12 Pendant 2 14 Wire Connector 3 15 Wrench Setscrew 1 16 Stud Threaded 1 1 4 2 17 Lockwasher 2 18 Knob Knurled 4 19 Screw 10 32 x 5 8 11 20 Screw 8 32 x 3 8 2 21 Screw 10 32 x 3 8 16 22 Washer Flat 16 27 Setscrew 1 31 Stud Threaded 1 2 24 Auxiliary Capacitor 762242 762242 762242 762242 762242 25 Cover Housing 760671 760671 15 760671 1 760671 14 760671 23 26 Harness 76145...

Отзывы: