12. Reinstall the hanger ball on the downrod as
follows. Route the motor leads through the hanger
ball and slide the hanger ball over the downrod
(Figure 7A). Install the pin through the holes at
the top of the downrod and slide the hanger ball
up the downrod, aligning the ball so the pin is
captured in the groove in the top of the hanger
ball. Pull the hanger ball up tight against the pin
and securely tighten the setscrew in the hanger
ball. A loose setscrew could create fan wobble.
13. Use three 10-32 x 3/8" pan head screws and flat
washers (supplied) to secure flange to blade
(Figure 8A). Repeat for the remaining four blades.
14. Use the 10 round recessed holes in the motor hub
marked with "5" and install the five blade assemblies
(ordered separately) in accordance with Step 15.
15. Attach one blade assembly to the motor hub using
two 10-32 x 5/8" oval head screws (supplied)
(Figure 9A). Do not tighten completely at this time.
Install remaining blade assemblies in the same
way. Gently snug all flange screws to the motor
hub, working around the hub in a clockwise
sequence. Next, securely tighten all flange screws,
again working in a clockwise sequence. Failure to
follow this procedure could result in fan wobble.
This completes the blade installation.
SETSCREW
DOWNROD
PIN
HANGER BALL
CEILING COVER
Figure 7A
BLADE
BLADE
FLANGE
10-32 x 3/8"
PAN HEAD
SCREW (3)
FLAT WASHER (3)
Figure 8A
9. Install the setscrew (supplied in the loose parts
bag) in the motor coupling and tighten using the
5/32” setscrew wrench (supplied) (Figure 5A).
NOTE: Make sure the unused black motor lead is
capped with a wire connector. Make sure all wires
and wire connectors are completely inside motor
coupling cover and not pinched between the
motor coupling cover and motor.
10. Screw two 1” threaded studs (supplied) into the
motor (Figure 6A). Leave approximately 7/8” of
the stud extending above the motor. Slide the
motor cover over the downrod and rotate the
cover until the threaded studs protrude; install two
knurled knobs (supplied) to secure the cover.
11. Position the ceiling cover over the downrod. Be
sure the cover is oriented correctly, with the large
opening at the top (Figure 7A).
7/8"
KNURLED KNOB
1" THREADED
STUD
MOTOR
MOTOR
COUPLING
COVER
WIRE
CONNECTORS
Figure 6A
SETSCREW
CLEVIS PIN
MOTOR
COUPLING
DOWNROD
HAIRPIN
CLIP
MOTOR
COUPLING
HAIRPIN
CLIP
CLEVIS
PIN
DOWNROD
LEADS TO BE
POSITIONED IN
SLOT IN MOTOR
COUPLING
CLEVIS
PIN
Figure 5A
6
It is critical that the pin in the hanger ball is properly
installed and the setscrew securely tightened.
Failure to verify that the pin and setscrew are
properly installed could result in the fan falling.
WARNING
!
To reduce the risk of personal injury, do not bend the
blade flanges when installing the blade flanges,
balancing the blades or cleaning the fan. Do not
insert foreign objects in between rotating fan blades.
WARNING
!