background image

14. Securely attach the hanger bracket to the outlet

box using the two screws supplied with the outlet
box (Figure 9B).

15. Carefully lift the fan and seat the hanger

ball/downrod assembly on the hanger bracket that
was just attached to the outlet box (Figure 10B).
Be sure the groove in the ball is lined up with tab
on the hanger bracket (Figure 9B).

NOTE: If you are installing a SR330 Remote
Control or a SW350 Wall Control to operate the
fan and light, refer to the installation instructions
and wiring diagrams shown in Section A of this
Owner’s Manual
.
16. For a wall control installation you will need a three-

wire (with ground) conductor cable between the
ceiling and wall outlet boxes. This will allow you to
control the fan separately from the lights. Figure
11B is a basic wiring diagram that will control the
uplight and downlight on a switch and the fan on a
separate control. Refer to the installation
instructions and wiring diagrams supplied with the
Emerson Fan Control Owner’s Manual.

a. Connect the green grounding lead from the

hanger ball and the green grounding lead from
the hanger bracket to the grounding conductor
of supply (this may be a bare wire or a wire
with green colored insulation). Securely
connect wires with wire connector supplied.

b. Securely connect the white wire from the

downrod to the supply white (neutral) wire
using wire connector supplied. Securely
connect the black wire from the downrod to
the supply black (hot) wire using wire

connector supplied.

CEILING

FLOOR

AT LEAST

7'

Figure 8B

TWO SCREWS
SUPPLIED WITH
OUTLET BOX

HANGER
BRACKET

TAB

OUTLET
BOX

OUTLET
BOX

HANGER
BRACKET

HANGER BALL/
DOWNROD  ASSEMBLY

NOTE: CEILING COVER,
SUPPLY WIRES AND
FAN WIRES OMITTED
FOR CLARITY.

Figure 9B

Figure 10B

10

10-32 x 5/8" OVAL HEAD SCREWS
(2 PER BLADE ASSEMBLY)

Figure 7B

To reduce the risk of personal injury, do not bend the
blade flange when installing the blade flanges,
balancing the blades or cleaning the fan. Do not
insert foreign objects in between rotating fan blades.

WARNING

!

The fan must be hung with at least 7' of clearance
from floor to blades (Figure 8B).

WARNING

!

To reduce the risk of fire, electric shock, or personal
injury, mount fan to outlet box marked acceptable for
fan support, and use screws supplied with outlet
box. Most outlet boxes commonly used for support
of light fixtures are not acceptable for fan support
and may need to be replaced. Consult a qualified
electrician if in doubt.

The outlet box must be securely anchored and capable
of withstanding a load of at least 50 lbs.

WARNING

!

WARNING

!

Hanger bracket must seat firmly against outlet box. If
the outlet box is recessed, remove wall board until
bracket contacts box. If bracket and/or outlet box are
not securely attached, the fan could wobble or fall.

WARNING

!

Failure to seat tab in groove could cause damage to
electrical wires and possible shock or fire hazard.

WARNING

!

To avoid possible electrical shock, be sure electricity
is turned off at the main fuse box before wiring.
NOTE: If you are not sure if the outlet box is
grounded, contact a licensed electrician for advice,
as it must be grounded for safe operation.

To avoid possible fire or shock, do not pinch wires
between the hanger ball/downrod assembly and
hanger bracket.

WARNING

!

WARNING

!

Содержание CROWN CF4500AB04

Страница 1: ... MO 63136 Include all model numbers shown on the product with your request To return the product to an authorized service center call 1 800 654 3545 for the address of the nearest authorized service center You will be responsible for all insurance freight or other transportation charges to our factory or authorized service center Your Emerson Air Comfort Ceiling Fan should be properly packed to av...

Страница 2: ...al Codes do not exist The ceiling fan must be grounded as a precaution against possible electrical shock Electrical installation should be made or approved by a licensed electrician 3 The outlet box and joist must be securely mounted an capable of reliably supporting a least 50 pounds Use only U L outlet boxes listed as acceptable for fan support and use the mounting screws provided with the outle...

Страница 3: ...sing Call Toll Free 1 800 654 3545 This product is designed to use only those parts supplied with this product and or any accessories designated specifically for use with this product by Emerson Company Substitution of parts or accessories not designated for use with this product by Emerson Company could result in personal injury or property damage WARNING WARNING Your new ceiling fan will require...

Страница 4: ... Choose the Section of Instructions from the List Below that Describes the Uplight Application You Wish to Achieve Begin Your Ceiling Fan Assembly with the Appropriate Section APPLICATIONS USE PAGE NO 1 Assembly Instructions for Installing Section A 5 the CF4800 or CF4500 Ceiling Fan with the Emerson SR330 Remote Control or the SW350 Wall Control 2 Assembly Instructions for Installing Section B 8 ...

Страница 5: ...d blue brown and yellow wires of the ceiling fan Figure 4A Wires must be connected color to color 7 Fold all wires from the downrod into the slot in the motor coupling slide the downrod down the wires and seat the downrod in the motor coupling All wires and wire connectors should be placed through the motor coupling slot beneath the downrod See Figure 5A 8 Align the clevis pin holes in the downrod...

Страница 6: ...LANGE 10 32 x 3 8 PAN HEAD SCREW 3 FLAT WASHER 3 Figure 8A 9 Install the setscrew supplied in the loose parts bag in the motor coupling and tighten using the 5 32 setscrew wrench supplied Figure 5A NOTE Make sure the unused black motor lead is capped with a wire connector Make sure all wires and wire connectors are completely inside motor coupling cover and not pinched between the motor coupling c...

Страница 7: ... outlet box Most outlet boxes commonly used for support of light fixtures are not acceptable for fan support and may need to be replaced Consult a qualified electrician if in doubt The outlet box must be securely anchored and capable of withstanding a load of at least 50 lbs WARNING WARNING Hanger bracket must seat firmly against outlet box If the outlet box is recessed remove wall board until bra...

Страница 8: ... installed to prevent the clevis pin from working loose Pull on the hanger ball to make sure the clevis pin is properly installed HANGER BALL DOWNROD CLEVIS PIN SETSCREW Figure 1B 8 21 Turn the receiver so that the flat side aligns with the open side of the hanger bracket Figure 13A Fold and position the wires into the space above the hanger ball and into the outlet box 22 Feed the wires and conne...

Страница 9: ...e groove in the top of the hanger ball Pull the hanger ball up tight against the pin and securely tighten the setscrew in the hanger ball A loose setscrew could create fan wobble DOWNROD SETSCREW Figure 3B 9 It is critical that the clevis pin in the motor coupling is properly installed and the setscrew securely tightened Failure to verify that the pin and setscrew are properly installed could resu...

Страница 10: ...O SCREWS SUPPLIED WITH OUTLET BOX HANGER BRACKET TAB OUTLET BOX OUTLET BOX HANGER BRACKET HANGER BALL DOWNROD ASSEMBLY NOTE CEILING COVER SUPPLY WIRES AND FAN WIRES OMITTED FOR CLARITY Figure 9B Figure 10B 10 10 32 x 5 8 OVAL HEAD SCREWS 2 PER BLADE ASSEMBLY Figure 7B To reduce the risk of personal injury do not bend the blade flange when installing the blade flanges balancing the blades or cleani...

Страница 11: ... possible fire or shock make sure that the electrical wires are completely inside the outlet box and not pinched between the ceiling cover and the ceiling WARNING Using Your Ceiling Fan 1 Restore electrical power to the outlet box by turning the electricity on at the main fuse box 2 When controlled by a wall switch check the operation of the fan by gently pulling on the 4 position speed control pu...

Страница 12: ...ews securing fan blade flanges to motor 3 Check to be sure screws which attach hub are loose the fan blade flanges to the motor hub are tight 4 Fan blade flanges not seated properly 4 Check to be sure the fan blade flanges seat firmly and uniformly to the surface of the motor hub If flanges are seated incorrectly loosen the flange screws and retighten according to Step 15 13 or 17 in Sections A or...

Страница 13: ...HOW TO ORDER REPAIR PARTS WHEN ORDERING REPAIR PARTS ALWAYS GIVE THE FOLLOWING INFORMATION NAME OF ITEM MODEL NUMBER THE PART NUMBER THE PART DESCRIPTION For repair parts phone 1 800 654 3545 6 13 1 2 3 16 14 15 7 10 20 19 9 21 22 8 24 18 17 5 4 23 27 12 11 29 30 25 26 31 18 28 TM 32 11 12 33 ...

Страница 14: ...4 762304 762304 Parts Bag containing 761629 761629 1 761629 761629 761629 761629 761629 1 761629 2 4 Pin Clevis 1 5 Clip Hairpin 1 11 Coupling 2 12 Pendant 2 14 Wire Connector 3 15 Wrench Setscrew 1 16 Stud Threaded 1 1 4 2 17 Lockwasher 2 18 Knob Knurled 4 19 Screw 10 32 x 5 8 11 20 Screw 8 32 x 3 8 2 21 Screw 10 32 x 3 8 16 22 Washer Flat 16 27 Setscrew 1 31 Stud Threaded 1 2 24 Auxiliary Capaci...

Страница 15: ...62304 762304 762304 Parts Bag containing 761629 1 761629 1 761629 1 761629 761629 1 761629 1 761629 761629 1 4 Pin Clevis 1 5 Clip Hairpin 1 11 Coupling 2 12 Pendant 2 14 Wire Connector 3 15 Wrench Setscrew 1 16 Stud Threaded 1 1 4 2 17 Lockwasher 2 18 Knob Knurled 4 19 Screw 10 32 x 5 8 11 20 Screw 8 32 x 3 8 2 21 Screw 10 32 x 3 8 16 22 Washer Flat 16 27 Setscrew 1 31 Stud Threaded 1 2 24 Auxili...

Страница 16: ...ip Hairpin 1 11 Coupling 2 12 Pendant 2 14 Wire Connector 3 15 Wrench Setscrew 1 16 Stud Threaded 1 1 4 2 17 Lockwasher 2 18 Knob Knurled 4 19 Screw 10 32 x 5 8 11 20 Screw 8 32 x 3 8 2 21 Screw 10 32 x 3 8 16 22 Washer Flat 16 27 Setscrew 1 31 Stud Threaded 1 2 24 Auxiliary Capacitor 762242 762242 762242 762242 762242 25 Cover Housing 760671 760671 15 760671 1 760671 14 760671 23 26 Harness 76145...

Отзывы: