Emerson CROWN CF4500AB04 Скачать руководство пользователя страница 5

5

1. Cut the white, blue, and black wires about 3"

above the motor coupling (Figure 1A). Strip
insulation 1/2" from end of wires and install a wire
connector on the black wire; this wire will not be
used. Remove the wire connectors from the red
and brown wires.

2. Remove the wire connector that is connecting the

two yellow leads (Figure 1A). Disconnect the two
yellow leads and reinstall a wire connector to the
yellow lead from the motor only; this lead will not
be used.

3. Loosen the setscrew in the hanger ball, slide the ball

down the downrod, and remove the clevis pin. Then
slide the hanger ball off the downrod (Figure 2A).
Retain all parts for reinstallation in Step 12.

4. Push the wiring harness connector and the

connector on the blue wire (both supplied with the
SR330 Remote Control and the SW350 Wall
Control), and the connector on the uplight yellow
lead assembly (supplied with the fan) through the
downrod until they all extend about 4” out of the
downrod (Figure 3A).

5. Cut all wires approximately 3" from the end of the

downrod. Strip insulation 1/2" from end of wires.

3"

WHITE WIRE

BLACK WIRE

BLUE WIRE

REMOVE WIRE
CONNECTORS
FROM RED AND
BROWN WIRES

INSULATE BLACK
WIRE USING WIRE
CONNECTOR

YELLOW
WIRE FROM
MOTOR

MOTOR
COUPLING

MOTOR COUPLING SLOT

WIRE
CONNECTOR

(Connected to
Yellow Lead
from Motor Only)

YELLOW LEAD

(Disconnected 
from wire connector)

Figure 1A

HANGER BALL

DOWNROD

CLEVIS PIN

SETSCREW

Figure 2A

4"

DOWNROD

CUT HERE

3"

UPLIGHT YELLOW LEAD ASSEMBLY

WIRING
HARNESS

BLUE WIRE

Figure 3A

6. Using wiring connectors (supplied), connect the

white, red, blue, brown, and yellow wires from the
downrod to the white, red, blue, brown and yellow
wires of the ceiling fan (Figure 4A). Wires must be
connected color-to-color.

7. Fold all wires from the downrod into the slot in the

motor coupling, slide the downrod down the wires
and seat the downrod in the motor coupling. All
wires and wire connectors should be placed
through the motor coupling slot beneath the
downrod (See Figure 5A).

8. Align the clevis pin holes in the downrod with the

holes in the motor coupling. Install the clevis pin
and secure with the hairpin clip. The clevis pin
must go through the holes in the motor coupling
and the holes in the downrod (Figure 5A). Push
the straight leg of the hairpin clip through the hole
near the end of the clevis pin until the curved
portion of the hairpin clip snaps around the clevis
pin. The hairpin clip must be properly installed to
prevent the clevis pin from working loose. 

FAN BLADES REMOVED
FOR CLARITY

TM

DOWNROD

BLACK WIRE

WHITE WIRE

WIRING HARNESS
CONNECTOR

YELLOW WIRE
TO YELLOW
WIRE

BLUE WIRE
TO 
BLUE WIRE

RECEIVER

BROWN WIRE
TO BROWN WIRE

YELLOW WIRE
TO YELLOW WIRE
        FROM UPLIGHT

LISTED GENERAL
USE ON/OFF
WALL SWITCH
(MUST BE
USED WITH SR120
REMOTE CONTROL)

RECEIVER
CONNECTOR

RED WIRE
TO RED WIRE

WHITE WIRE
TO WHITE WIRE

BLACK WIRE
(NOT USED)

BLUE WIRE
TO BLUE WIRE

BLACK WIRE

WHITE WIRE

BLACK
WIRE

WHITE
WIRE

BLACK

WHITE

BLACK

SW140
WALL
CONTROL

FAN
HOUSING

TO

120V SUPPLY

TO

120V SUPPLY

YELLOW WIRE
FROM  MOTOR
COUPLER
(NOT USED)

LIGHT FIXTURE

Figure 4A

It is critical that the clevis pin in the motor coupling
is properly installed and the setscrew securely
tightened. Failure to verify that the pin and setscrew
are properly installed could result in the fan falling.

WARNING

!

SECTION A

Assembly Instructions for Installing the CF4800 or CF4500 Ceiling Fan

with the Emerson SR330 Remote Control or the SW350 Wall Control

Содержание CROWN CF4500AB04

Страница 1: ... MO 63136 Include all model numbers shown on the product with your request To return the product to an authorized service center call 1 800 654 3545 for the address of the nearest authorized service center You will be responsible for all insurance freight or other transportation charges to our factory or authorized service center Your Emerson Air Comfort Ceiling Fan should be properly packed to av...

Страница 2: ...al Codes do not exist The ceiling fan must be grounded as a precaution against possible electrical shock Electrical installation should be made or approved by a licensed electrician 3 The outlet box and joist must be securely mounted an capable of reliably supporting a least 50 pounds Use only U L outlet boxes listed as acceptable for fan support and use the mounting screws provided with the outle...

Страница 3: ...sing Call Toll Free 1 800 654 3545 This product is designed to use only those parts supplied with this product and or any accessories designated specifically for use with this product by Emerson Company Substitution of parts or accessories not designated for use with this product by Emerson Company could result in personal injury or property damage WARNING WARNING Your new ceiling fan will require...

Страница 4: ... Choose the Section of Instructions from the List Below that Describes the Uplight Application You Wish to Achieve Begin Your Ceiling Fan Assembly with the Appropriate Section APPLICATIONS USE PAGE NO 1 Assembly Instructions for Installing Section A 5 the CF4800 or CF4500 Ceiling Fan with the Emerson SR330 Remote Control or the SW350 Wall Control 2 Assembly Instructions for Installing Section B 8 ...

Страница 5: ...d blue brown and yellow wires of the ceiling fan Figure 4A Wires must be connected color to color 7 Fold all wires from the downrod into the slot in the motor coupling slide the downrod down the wires and seat the downrod in the motor coupling All wires and wire connectors should be placed through the motor coupling slot beneath the downrod See Figure 5A 8 Align the clevis pin holes in the downrod...

Страница 6: ...LANGE 10 32 x 3 8 PAN HEAD SCREW 3 FLAT WASHER 3 Figure 8A 9 Install the setscrew supplied in the loose parts bag in the motor coupling and tighten using the 5 32 setscrew wrench supplied Figure 5A NOTE Make sure the unused black motor lead is capped with a wire connector Make sure all wires and wire connectors are completely inside motor coupling cover and not pinched between the motor coupling c...

Страница 7: ... outlet box Most outlet boxes commonly used for support of light fixtures are not acceptable for fan support and may need to be replaced Consult a qualified electrician if in doubt The outlet box must be securely anchored and capable of withstanding a load of at least 50 lbs WARNING WARNING Hanger bracket must seat firmly against outlet box If the outlet box is recessed remove wall board until bra...

Страница 8: ... installed to prevent the clevis pin from working loose Pull on the hanger ball to make sure the clevis pin is properly installed HANGER BALL DOWNROD CLEVIS PIN SETSCREW Figure 1B 8 21 Turn the receiver so that the flat side aligns with the open side of the hanger bracket Figure 13A Fold and position the wires into the space above the hanger ball and into the outlet box 22 Feed the wires and conne...

Страница 9: ...e groove in the top of the hanger ball Pull the hanger ball up tight against the pin and securely tighten the setscrew in the hanger ball A loose setscrew could create fan wobble DOWNROD SETSCREW Figure 3B 9 It is critical that the clevis pin in the motor coupling is properly installed and the setscrew securely tightened Failure to verify that the pin and setscrew are properly installed could resu...

Страница 10: ...O SCREWS SUPPLIED WITH OUTLET BOX HANGER BRACKET TAB OUTLET BOX OUTLET BOX HANGER BRACKET HANGER BALL DOWNROD ASSEMBLY NOTE CEILING COVER SUPPLY WIRES AND FAN WIRES OMITTED FOR CLARITY Figure 9B Figure 10B 10 10 32 x 5 8 OVAL HEAD SCREWS 2 PER BLADE ASSEMBLY Figure 7B To reduce the risk of personal injury do not bend the blade flange when installing the blade flanges balancing the blades or cleani...

Страница 11: ... possible fire or shock make sure that the electrical wires are completely inside the outlet box and not pinched between the ceiling cover and the ceiling WARNING Using Your Ceiling Fan 1 Restore electrical power to the outlet box by turning the electricity on at the main fuse box 2 When controlled by a wall switch check the operation of the fan by gently pulling on the 4 position speed control pu...

Страница 12: ...ews securing fan blade flanges to motor 3 Check to be sure screws which attach hub are loose the fan blade flanges to the motor hub are tight 4 Fan blade flanges not seated properly 4 Check to be sure the fan blade flanges seat firmly and uniformly to the surface of the motor hub If flanges are seated incorrectly loosen the flange screws and retighten according to Step 15 13 or 17 in Sections A or...

Страница 13: ...HOW TO ORDER REPAIR PARTS WHEN ORDERING REPAIR PARTS ALWAYS GIVE THE FOLLOWING INFORMATION NAME OF ITEM MODEL NUMBER THE PART NUMBER THE PART DESCRIPTION For repair parts phone 1 800 654 3545 6 13 1 2 3 16 14 15 7 10 20 19 9 21 22 8 24 18 17 5 4 23 27 12 11 29 30 25 26 31 18 28 TM 32 11 12 33 ...

Страница 14: ...4 762304 762304 Parts Bag containing 761629 761629 1 761629 761629 761629 761629 761629 1 761629 2 4 Pin Clevis 1 5 Clip Hairpin 1 11 Coupling 2 12 Pendant 2 14 Wire Connector 3 15 Wrench Setscrew 1 16 Stud Threaded 1 1 4 2 17 Lockwasher 2 18 Knob Knurled 4 19 Screw 10 32 x 5 8 11 20 Screw 8 32 x 3 8 2 21 Screw 10 32 x 3 8 16 22 Washer Flat 16 27 Setscrew 1 31 Stud Threaded 1 2 24 Auxiliary Capaci...

Страница 15: ...62304 762304 762304 Parts Bag containing 761629 1 761629 1 761629 1 761629 761629 1 761629 1 761629 761629 1 4 Pin Clevis 1 5 Clip Hairpin 1 11 Coupling 2 12 Pendant 2 14 Wire Connector 3 15 Wrench Setscrew 1 16 Stud Threaded 1 1 4 2 17 Lockwasher 2 18 Knob Knurled 4 19 Screw 10 32 x 5 8 11 20 Screw 8 32 x 3 8 2 21 Screw 10 32 x 3 8 16 22 Washer Flat 16 27 Setscrew 1 31 Stud Threaded 1 2 24 Auxili...

Страница 16: ...ip Hairpin 1 11 Coupling 2 12 Pendant 2 14 Wire Connector 3 15 Wrench Setscrew 1 16 Stud Threaded 1 1 4 2 17 Lockwasher 2 18 Knob Knurled 4 19 Screw 10 32 x 5 8 11 20 Screw 8 32 x 3 8 2 21 Screw 10 32 x 3 8 16 22 Washer Flat 16 27 Setscrew 1 31 Stud Threaded 1 2 24 Auxiliary Capacitor 762242 762242 762242 762242 762242 25 Cover Housing 760671 760671 15 760671 1 760671 14 760671 23 26 Harness 76145...

Отзывы: