ACC/ARTM-7221/FC Installation Guide (6806800E98A
)
Installation
Module Installation
36
2.4
Module Installation
The RTM can be installed into a powered or nonpowered system and must be installed into a
AdvancedTCA system without a zone 3 midplane.
2.4.1
Nonpowered System
Installation Procedure
1.
Locate the slot the RTM is to be installed into at the shelf's rear which must be the
same as that of the front blade
2.
Ensure that the top and bottom handles are in outward position
3.
Insert the RTM into the shelf by placing the top and bottom edges in the card guides
of the slot
4.
Slide the RTM into the slot
5.
Hook the lower and the upper handle into the shelf rail recesses
6.
Fully insert the RTM and lock it to the shelf by pressing the two components of the
lower and upper handles together and turning the handles towards the face plate
7.
Tighten the two face plate screws
8.
Plug interface cables into the face plate connectors, if applicable
9.
Turn on system power
RTM Damage
Installing the RTM with other blades than the PENT/ATCA-7221 damages the RTM.
Only install the RTM with the Emerson PENT/ATCA-7221 blade.
Damage of Circuits
Electrostatic discharge and incorrect RTM installation and removal can damage
circuits or shorten their life.
Before touching the RTM or electronic components, make sure that you are working
in an ESD-safe environment.
Содержание ACC/ARTM-7221/FC
Страница 1: ...ACC ARTM 7221 FC Installation Guide 6806800E98A March 2008 ...
Страница 6: ...ACC ARTM 7221 FC Installation Guide 6806800E98A List of Tables 6 ...
Страница 8: ...ACC ARTM 7221 FC Installation Guide 6806800E98A List of Figures 8 ...
Страница 16: ...ACC ARTM 7221 FC Installation Guide 6806800E98A Safety Notes 16 ...
Страница 20: ...ACC ARTM 7221 FC Installation Guide 6806800E98A Sicherheitshinweise 20 ...
Страница 26: ...ACC ARTM 7221 FC Installation Guide 6806800E98A Introduction Ordering Information 26 ...
Страница 54: ...ACC ARTM 7221 FC Installation Guide 6806800E98A 60 ...