ACC/ARTM-7221/FC Installation Guide (6806800E98A

)

Installation

Requirements

30

   

2.2.2.3

Environmental Requirements

The environmental conditions must be tested and proven in the used system configuration. The 
conditions refer to the surrounding of the board within the user environment.  

z

Operating temperatures refer to the temperature of the air circulating around the 
RTM and not to the actual component temperature.

z

To ensure that the operating conditions are met, forced air cooling is required 
within the chassis environment.

z

The environmental values given in the table below only apply to the RTM without 
any hard disk. If installing hard disks, their environmental requirements must also 
be taken into account. If you use the RTM together with a hard disk, also check the 
environmental requirements of the hard disk and make sure that the most 
restrictive requirements are met.

RTM damage
High humidity and condensation on the RTM surface causes short circuits.
Do not operate the RTM outside the specified environmental limits. Make sure the 
RTM is completely dry and there is no moisture on any surface before applying power. 
Do not operate the RTM below 0ºC.

Table 2-1 Environmental Requirements

Requirement

Operating

Non-Operating

Temperature

+5ºC to +40ºC (normal 
operation) according to 
NEBS Standard GR-63-
CORE

-5ºC to +55ºC (exceptional 
operation) according to 
NEBS Standard GR-63-
CORE

All values may be further 
limited by installed 
accessories with more 
restrictive environmental 
requirements.  

-40ºC to +70ºC (may be further limited by installed 
accessories) 

Temp. Change

+/- 0.25ºC/min according to 
NEBS Standard GR-63-
CORE

 +/- 0.25ºC/min

Rel. Humidity

5% to 95% non-condensing 
according to Emerson-
internal environmental 
requirements

5% to 95% non-condensing according to Emerson-
internal environmental requirements

Содержание ACC/ARTM-7221/FC

Страница 1: ...ACC ARTM 7221 FC Installation Guide 6806800E98A March 2008 ...

Страница 2: ...ocument and to make changes from time to time in the content hereof without obligation of Emerson to notify any person of such revision or changes Electronic versions of this material may be read online downloaded for personal use or referenced in another document as a URL to a Emerson website The text itself may not be published commercially in print or electronic form edited translated or otherw...

Страница 3: ...tart 29 2 2 1 Package Inspection 29 2 2 2 Requirements 29 2 2 2 1 Power Requirements 29 2 2 2 2 Backplane Requirements 29 2 2 2 3 Environmental Requirements 30 2 3 On Board Connectors 33 2 3 1 IPMB1 34 2 3 2 SATA for On board Hard Disks 35 2 3 3 Serial ATA for External Hard Disks 37 2 4 Module Installation 38 2 4 1 Nonpowered System 38 2 4 2 Powered System 39 2 5 Face Plate Controls Indicators and...

Страница 4: ...Guide 6806800E98A Contents 4 2 5 3 Reset Key 50 2 6 Zone 3 Connectors 50 2 7 Devices Connected to RTM s Mezzanine Management Controller 53 A Related Documentation 57 A 1 Emerson Network Power Embedded Computing Documents 57 Index 59 ...

Страница 5: ...C Installation Guide 6806800E98A 5 Table 1 1 Manual Organization 21 Table 1 2 Mechanical Data 25 Table 2 1 Environmental Requirements 31 Table 2 2 LED Description 49 Table 2 3 Available IPMI Sensors 54 List of Tables ...

Страница 6: ...ACC ARTM 7221 FC Installation Guide 6806800E98A List of Tables 6 ...

Страница 7: ...isks 37 Figure 2 9 Serial ATA for External Hard Disks Connector Pinout 37 Figure 2 10 Face Plate 43 Figure 2 11 USB Connector Pinout 44 Figure 2 12 Serial Connector Pinout 45 Figure 2 13 Fiber Channel Connector Pinout 45 Figure 2 14 Keyboard Mouse Connector Pinout 46 Figure 2 15 E1 T1 Connector Pinout 47 Figure 2 16 Face Plate LEDs 48 Figure 2 17 Face Plate Reset Key 50 Figure 2 18 Location of Zon...

Страница 8: ...ACC ARTM 7221 FC Installation Guide 6806800E98A List of Figures 8 ...

Страница 9: ...rd Information Block CPU Central Processing Unit CTS Clear to Send DTR Data Terminal Ready EMC Electromagnetic Compatibility ESD Electrostatic Sensitive Device FCC Federal Communications Commission GND Ground HDD Hard Disk Drive IPMB Intelligent Platform Management Bus IPMC Intelligent Platform Management Controller IPMI Intelligent Platform Management Interface LED Light Emitting Diode LFM Linear...

Страница 10: ...ATA SFP Small Form Factor Pluggable UL Underwriters Laboratory Inc Abbreviation Definition Notation Description 0x00000000 Typical notation for hexadecimal numbers digits are 0 through F for example used for addresses and offsets 0b0000 Same for binary numbers digits are 0 and 1 bold Used to emphasize a word Screen Used for on screen output and code related elements or commands in body text Courie...

Страница 11: ...Description 223454 AA December 2004 Preliminary Installation Guide 223454 AB March 2005 Changed Force Computers to Motorola throughout the document Added section About this manual replaced Force with Motorola copyright renamed ARTM from ARTM 720 to ARTM 7120 new Motorola name 223454 AC June 2005 Updated front panel figures editorial changes 223454 AD December 2005 Updated safety notes included 3D ...

Страница 12: ... want to know what you think about our manuals and how we can make them better Mail comments to us by filling out the following online form http www emersonnetworkpowerembeddedcomputing com Contact Us Online Form In Area of Interest select Technical Documentation Be sure to include the title part number and revision of the manual and tell us how you used it ...

Страница 13: ...trical engineering are authorized to install remove or maintain the product The information given in this manual is meant to complete the knowledge of a specialist and must not be taken as replacement for qualified personnel EMC The RTM has been tested in a standard Emerson system and found to comply with the limits for a Class A digital device in this system pursuant to part 15 of the FCC Rules E...

Страница 14: ...until the blue LED is permanently ON RTM Damage Installing the RTM with other blades than the PENT ATCA 7221 damages the RTM Only install the RTM with the Emerson PENT ATCA 7221 blade Operation RTM damage High humidity and condensation on the RTM surface causes short circuits Do not operate the RTM outside the specified environmental limits Make sure the RTM is completely dry and there is no moist...

Страница 15: ...to a RJ 45 connector labeled as E1 T1 may damage the telephone or the RTM Therefore only connect E1 T1 networks to RJ 45 connectors labeled as E1 T1 ports and only connect serial devices to RJ 45 connectors labeled as COM Environment Always dispose of used RTMs according to your country s legislation if possible in an environmentally acceptable way Laser Some variants of the RTM are a Class I lase...

Страница 16: ...ACC ARTM 7221 FC Installation Guide 6806800E98A Safety Notes 16 ...

Страница 17: ...tallation Wartung und Betrieb dürfen nur von durch Emerson ausgebildetem oder im Bereich Elektronik oder Elektrotechnik qualifiziertem Personal durchgeführt werden Die in diesem Handbuch enthaltenen Informationen dienen ausschließlich dazu das Wissen von Fachpersonal zu ergänzen können es aber in keinem Fall ersetzen EMV Das RTM wurde in einem Emerson Standardsystem getestet Es erfüllt die für dig...

Страница 18: ...NT ATCA 7221 Front Blade Datenverlust Wenn Sie das RTM aus einem eingeschaltetem System herausziehen während die blaue LED auf dem Front Blade noch blinkt gehen Daten verloren Bevor Sie das RTM aus einem eingeschaltetem System herausziehen müssen Sie den Steckplatz durch Oeffnen des unteren Griffs am Front Blade ausschalten und warten bis die blaue LED auf dem Front Blade permanent leuchtet Betrie...

Страница 19: ...r anschließen kann das Telefon oder das RTM beschädigt werden Schließen Sie deshalb nur E1 T1 Netze an die mit E1 T1 gekennzeichneten Stecker an und schließen Sie nur serielle Geräte an die mit COM gekennzeichneten Stecker an Umweltschutz Entsorgen Sie alte RTMs stets gemäß der in Ihrem Land gültigen Gesetzgebung wenn möglich immer umweltfreundlich Laser Einige Varianten des Produktes sind Laserpr...

Страница 20: ...ACC ARTM 7221 FC Installation Guide 6806800E98A Sicherheitshinweise 20 ...

Страница 21: ...ompany Be sure to include the title part number and revision of the manual and tell how you used it Table 1 1 Manual Organization Chapter Content Description Using This Guide Lists all conventions and abbreviations used in this manual and outlines the revision history Other Sources of Information Lists related documentation and specifications Safety Notes Describes the safety information which hav...

Страница 22: ...a the zone 3 connectors The ACC ARTM 7221 FC provides the following z System management IPMI Compliancy to IPMI V 1 5 Management Controller MMC based on Atmega64 Several status sensors e g voltage and temperature z Interfaces Two USB 2 0 Two RS 232 Two fibre channel One keyboard mouse Four E1 T1 Only available if a Emerson PMC 8260 DS1 module is installed on the front blade IPMB1 One SATA for on b...

Страница 23: ...three Product is designed to support NEBS level three The compliance tests must be done with the customer target system PICMG 3 0 R 1 0 Defines mechanics blade dimensions power distribution power and data connectors and system management 1 A test has shown that the RTM is not compliant to the Unpacked Equipment Shock Criteria as defined in NEBS GR 63 4 3 2 The test consisted of dropping the RTM fr...

Страница 24: ...ACC ARTM 7221 FC Installation Guide 6806800E98A Introduction Standard Compliances 24 Figure 1 1 Declaration of Conformity ...

Страница 25: ... and weight of the RTM 1 5 Ordering Information As of the time of writing this guide the following RTM variant was available Consult your local sales representative for a more up to date list Table 1 2 Mechanical Data Feature Value Physical Dimension of PCB 322 25 mm x 70 mm Weight of RTM 0 7 kg Order Number Variant name 121914 ACC ARTM 7221 FC ...

Страница 26: ...ACC ARTM 7221 FC Installation Guide 6806800E98A Introduction Ordering Information 26 ...

Страница 27: ...cessary and will be described in further detail in the sections of this chapter Figure 2 1 Action Plan Part 1 Start Installation Make sure requirements are met Inspect delivered package items Connect install hard disk Connect IPMB1 device YES YES NO NO Hard disk to be connected or to be installed IPMB1 device to be connected A ...

Страница 28: ...d Switch on slot power Connect cables to face plate connectors Cables to face plate connectors necessary YES NO A Switch on system power Install RTM into nonpowered system Switch off slot power Install RTM Install RTM Install RTM YES YES YES NO NO NO RTM to be installed into powered system Is slot powered Front blade installed ...

Страница 29: ...nts Before installing the RTM make sure the requirements described in this section are met 2 2 2 1 Power Requirements The RTM draws approximately 5W from the front blade it is connected to to 2 2 2 2 Backplane Requirements For installing the RTM you need a system without a zone 3 midplane Damage of Circuits Electrostatic discharge and incorrect RTM installation and removal can damage circuits or s...

Страница 30: ...s of the hard disk and make sure that the most restrictive requirements are met RTM damage High humidity and condensation on the RTM surface causes short circuits Do not operate the RTM outside the specified environmental limits Make sure the RTM is completely dry and there is no moisture on any surface before applying power Do not operate the RTM below 0ºC Table 2 1 Environmental Requirements Req...

Страница 31: ...ude 1g 1 mm amplitude 2 0 g Shock 5 g 11 ms halfsine according to Emerson internal environmental requirements 15 g 11 ms half sine according to Emerson internal environmental requirements Free Fall 1 200 mm all edges and corners Table 2 1 Environmental Requirements continued Requirement Operating Non Operating Location Component Temperature Limit 1 Installed hard disk 60ºC 2 TX1322 TLV 1 transform...

Страница 32: ... on board hard disk 2 3 1 IPMB1 The RTM provides an on board IPMB1 connector which enables you to attach a device such as a fan to the IPMB1 interface of the ATCA 7221 The following figure shows the location of the IPMB1 connector The following figure shows the pinout of the IPMB1 connector Figure 2 4 Location of IPMB1 Connector Figure 2 5 IPMB1 Connector Pinout IPMB1 Connector 1 2 3 GND IPMB1_SDA...

Страница 33: ...igure allows to install an on board 2 5 hard disk which is available as accessory kit called ACC ATCA 7221 HDD SATA for the RTM For further information refer to the ACC ATCA 7221 HDD SATA Installation Guide which can be downloaded from the Emerson literature catalog Figure 2 6 Location of Serial ATA Connector for On Board Hard Disks SATA Connector for on board hard disks ...

Страница 34: ...Disks 34 The following figure shows the connector pinout Figure 2 7 Serial ATA for On Board Hard Disk Connector Pinout 1 7 1 2 3 4 5 6 7 GND SATA0_TX SATA0_TX GND SATA0_RX SATA0_RX GND 1 15 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 3 3V 3 3V 3 3V GND GND GND 5V 5V 5V GND RSV 12V 12V 12V 12V ...

Страница 35: ...ws to connect an external SATA hard disk to the RTM The power for the SATA hard disk must be provided externally The following figure shows the connector pinout Figure 2 8 Location of Serial ATA Connector for External Hard Disks Figure 2 9 Serial ATA for External Hard Disks Connector Pinout SATA Connector for external hard disks 1 7 1 2 3 4 5 6 7 GND SATA_TX_P SATA_TX_M GND SATA_RX_M SATA_RX_P GND...

Страница 36: ...t 4 Slide the RTM into the slot 5 Hook the lower and the upper handle into the shelf rail recesses 6 Fully insert the RTM and lock it to the shelf by pressing the two components of the lower and upper handles together and turning the handles towards the face plate 7 Tighten the two face plate screws 8 Plug interface cables into the face plate connectors if applicable 9 Turn on system power RTM Dam...

Страница 37: ... with Installed Front Blade 1 Locate the slot the RTM is to be installed into at the shelf s rear which must be the same as that of the front blade 2 Open the lower handle of the front blade The blue LED on the front blade starts to flash while the front blade powers down 3 Wait until the blue LED on the front blade is ON 4 Ensure that the top and the bottom handles of the RTM are in outward posit...

Страница 38: ...stallation Procedure without Installed Front Blade 1 Ensure that the top and bottom handles of the RTM are in outward position 2 Insert the RTM into the shelf by placing the top and bottom edges in the card guides of the slot 3 Slide the RTM into the slot 4 Hook the lower and the upper handle into the shelf rail recesses 5 Fully insert the RTM and lock it to the shelf by pressing the two component...

Страница 39: ...er and the upper handle by pressing the two handle components together and turning the handles outwards 5 Remove interface cables from face plate connectors if applicable 6 Remove the RTM from slot Data loss Removing the RTM with the system power on and the blue LED on the front blade still flashing causes data loss Before removing the RTM from a powered system power down the slot by opening the l...

Страница 40: ...Installation Guide 6806800E98A Installation Face Plate Controls Indicators and Connectors 40 2 5 Face Plate Controls Indicators and Connectors The following figure shows the face plate of the RTM Figure 2 10 Face Plate ...

Страница 41: ...x stands for the number of the interface 2 5 1 2 Serial Figure 2 11 USB Connector Pinout 1 2 3 4 1 4 VP5_USB USB_x_D_M USB_x_D_P GND RTM and telephone damage E1 T1 interfaces on face plate On the face plate RJ 45 connectors are used for different interfaces Mismatching the interfaces i e connecting a telephone or an E1 T1 network to the serial interfaces labeled as COM or connecting a serial devic...

Страница 42: ...which pin 2 5 1 4 Keyboard Mouse One PS 2 keyboard or one PS 2 mouse can directly be connected to the RTM If you use a splitter cable you can connect a PS 2 keyboard and mouse simultaneously The following connector pinout gives information on which signal is assigned to which pin Figure 2 12 Serial Connector Pinout RJ45_x_RI RJ45_x_DCD RJ45_x_DTR GND RJ45_x_RXD RJ45_x_TXD RJ45_x_CTS RJ45_x_RTS 1 2...

Страница 43: ...s assigned to which pin The x stands for the number of the interface RTM and telephone damage E1 T1 interfaces on face plate On the face plate RJ 45 connectors are used for different interfaces Mismatching the interfaces i e connecting a telephone or an E1 T1 network to the serial interfaces labeled as COM or connecting a serial device to a RJ 45 connector labeled as E1 T1 may damage the telephone...

Страница 44: ...ACC ARTM 7221 FC Installation Guide 6806800E98A Installation LEDs 44 2 5 2 LEDs The following figure highlights the LEDs available at the RTM s face plate Figure 2 16 Face Plate LEDs Face Pate LEDs ...

Страница 45: ... s face plate OK RTM Power Status Green The RTM power has been enabled by the MMC OFF RTM power is disabled ACT This LED is controlled by upper layer software such as middleware or applications It works in parallel to the ACT LED at the front blade s face plate H S Indicates whether the RTM can be installed or removed During RTM installation Permanently blue RTM powers up Flashing blue RTM communi...

Страница 46: ... key By pressing the reset key you reset the RTM and the front blade 2 6 Zone 3 Connectors The RTM provides two zone 3 connectors P30 and P31 They provide interfaces to z Serial RS 232 z Serial ATA z Fiber channels z USB z Keyboard Mouse z IPMI Figure 2 17 Face Plate Reset Key Reset Key The RTM s MMC and the front blade s IPMC are not reset via this key ...

Страница 47: ...n of Zone 3 Connectors P30 and P31 Figure 2 19 P30 Connector Pinout Rows a d P31 P30 1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10 a b c d a b c d e f g h RS232_1_RXD RS232_1_DCD n c USB0_P n c FC0_TX_P SATA0_TX_P n c IPMB1_SCL VP12_RTM RS232_1_TXD RS232_1_DTR n c USB0_M n c FC0_TX_M SATA0_TX_M n c IPMB1_SDA VP12_RTM RS232_1_RTS RS232_1_DSR n c USB1_P n c FC0_RX_P SATA0_RX_P n c V3P3_IPMI V3P3_RTM RS2...

Страница 48: ...2_2_DCD KBD_DAT n c n c FC1_TX_P SATA1_TX_P n c BRD_PRES_N VP5_RTM RS232_2_RTS RS232_2_DSR MSY_DAT n c n c FC1_RX_P SATA1_RX_P n c RTM_RST_KEY_N RTM_SCL RS232_2_CTS RS232_2_RI MSY_CLK n c n c FC1_RX_M SATA1_RX_M n c RTM_RST_N RTM_SDA 1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10 a b c d a b c d e f g h n c PMC1_IO_34 PMC1_IO_42 n c n c n c n c n c n c VP12_RTM n c PMC1_IO_36 PMC1_IO_44 n c n c n c n c...

Страница 49: ...address is 0xAA z Temperature voltage and other status sensors The following table lists all IPMI sensors Figure 2 22 P31 Connector Pinout Rows e h 1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10 e f g h a b c d e f g h n c PMC1_IO_40 PMC1_IO_48 n c n c n c n c n c n c n c n c PMC1_IO_38 PMC1_IO_46 n c n c n c n c n c n c n c PMC1_IO_33 PMC1_IO_41 n c n c n c n c n c n c n c n c PMC1_IO_35 PMC1_IO_43 n ...

Страница 50: ...hile Payload powered ON Voltage 5V USB2 Voltage 5V voltage level of USB interface 2 Analog While Payload powered ON Volt 5V KB PWR Voltage 5V voltage level of keyboard mouse interface Analog While Payload powered ON ARTM FW Revision Firmware revision Application firmware revision Discrete Always ARTM 7221 MMC Reset type Status and type of the last reset of the IPMC Discrete Always BOOT FW Revision...

Страница 51: ...tion Search This site provides the most up to date copies of Emerson Network Power Embedded Computing product documentation Note Check the Motorola literature catalog for any errata sheets that may be applicable to the RTM Company Organisation www Document Emerson PENT ATCA 7221 Reference Guide PENT ATCA 7221 Control via IPMI Programmer s Guide ACC ATCA 7221 HDD SATA Installation Guide ACC ARTM 72...

Страница 52: ...ACC ARTM 7221 FC Installation Guide 6806800E98A Related Documentation Emerson Network Power Embedded Computing Documents 58 ...

Страница 53: ...ector 45 USB connector 44 I I2C address of IDROM 54 IDROM I2C address 54 Installation Into nonpowered systems 38 Into powered systems 39 IPMI interface connector 34 IPMI sensors 54 R Requirements Environmental requirements 30 Power requirements 29 S Serial ATA interface For external hard disk 37 For on board hard disk 35 Standard compliances 23 T Temperatures Critical hot spots 32 Non operating 31...

Страница 54: ...ACC ARTM 7221 FC Installation Guide 6806800E98A 60 ...

Отзывы: