background image

 

 

 

4.

 

PRECAUTIONARY MEASURE 

 

u

 

Important! For normal operation of the EMERALD it is necessary to comply with all require-
ments for its operation and service maintenance specified in this specification and operating 
manual. 

u

 

Prior to start using the device you are requested to read carefully all instructions. If you have 
any questions about the connection or operation of the EMERALD you are requested to con-
sult with our authorized dealers or call our customer service. 

u

 

When using the electrical device you shall always follow the basic safety guidelines to reduce 
the risk of fire, electric shock, and / or personal injury. 

u

 

To  prevent  the  electric  shock,  do  not  lay  the  electrical  wires  of  the  sensor  disc  and  power 
source, body or other electronic components of the device near the water or other liquid sub-
stances. The outlet shall not be located directly above the sink or in any other place where the 
water can get into it. Avoid hanging of electrical wires from the edge of the tabletop and avoid 
their contact with hot surfaces. Prior to connect to the electrical network, make sure that the 
device and all its elements are dry. During the operation all elements of the EMERALD shall 
be dry and not leak. 

u

 

Water purification device is not intended for use by children, people with physical and mental 
disabilities, with the lack of necessary experience and knowledge except in cases of direct 
instruction by a person responsible for their safety. 

u

 

Use only the spare parts that are authorized by the manufacturer. Do not use the device with 
damaged electrical wires of the sensor disc and the power source after breaking their integrity. 

u

 

Do not use this device for other purposes. Do not use the device outdoors. The device is in-
tended for home use only. Do not use the device for the desalination of water . 

u

 

Do not disassemble or repair the device by yourself. Contact the authorized service center. In 
order to reduce the risk of fire or electric shock it is strongly recommended not to disassemble 
the electronic components of the device. 

u

 

Avoid the rough handling with the device; do not drop or hit it. Do not store or transport the 
device with residual water at ambient temperature below 0 ºС. Use the device only in an up-
right position; 

u

 

Before starting the operation make sure that all hydraulic and electrical connections are se-
cured. Do not leave the running device unattended; 

u

 

In case of absence for a long time at home it is recommended to shut off cold water supply 
line; 

u

 

Do not use the device for purification of microbiologically unsafe water or the water of un-
known origin without the proper prior disinfection. If you have the weakened immune system 
or if for medical reasons you need absolutely pure water, then consult with medical profes-
sional prior to start using the device. 

u

 

Additional mechanical filters shall be installed down to water inlet into the device if there are 
visible suspended matters, turbidity, rust flakes in tap water. 

u

 

Make sure   the device is disconnected from the power supply during long interruptions. Do 
not use any other power-supply units and adapters instead of the included power    adaptor. 
Check the power cord, power plug and the device itself for damages. If any damage is found, 
then contact your nearest service center for the inspection or repair. 

u

 

The device should not contain the materials with which the plumber seals the joints. Avoid to 
entry into the device the vegetable oil, technical petroleum jelly or other lubricants, solvents, 
ammonia, alcohols or powerful cleaning solutions. They can seriously damage the device. 

u

 

Avoid the contact of the electrical components of the device with water and any other liquids 
(including the contact of water with the sensor tap of clean water supply and its LED part). 

u

 

The electrical outlet shall be grounded to connect the power cord. If you need to install a new 
outlet it should be done by the electrician with the appropriate permit or certificate issued in 

Содержание Home 4

Страница 1: ...PASSPORT AND OPERATION MANUAL EMERALD HOME 4 FOR PURIFICATION AND ELECTRIAL TREATMENT OF FRESH WATER...

Страница 2: ...e connection above the sink 10 Connection of diverter to the tap 10 Connection of the device to the electric network 11 6 OPERATION OF THE DEVICE 12 Cold tap water supply to the device 12 LED indicati...

Страница 3: ...e nature Reproducing the most complex natural processes of water purification and treatment has become possible due to the creation of highly reliable electrochemical modules which are the main elemen...

Страница 4: ...the water in the form of aerosol to moisturize the skin Moisturizing masks with the use of antioxidant water will have the special effect Pets and Plants the pets will prefer the antioxidant water to...

Страница 5: ...re ac celerated tens of thousands of times due to the use of the latest technologies and electrochemical modules The catalytic and electrokinetic filters work in purity They are located after the anod...

Страница 6: ...ified from free chlorine and chlororganic compounds u Improves the taste of water and eliminates the unpleasant odors due to the anodic removal of phenols and hydrogen sulfide Fig 3 Cathodic chamber o...

Страница 7: ...thorized service center In order to reduce the risk of fire or electric shock it is strongly recommended not to disassemble the electronic components of the device u Avoid the rough handling with the...

Страница 8: ...er elements and the electro chemical module is required see the section MAINTENANCE OF THE DEVICE u Do not use the first 30 liters of purified water immediately after connecting the device or after wa...

Страница 9: ...and the parts included in the kit to connect the device in accordance with the diagram in Fig 7 ATTENTION Before starting the device connec tion procedure be sure to familiarize yourself with the bas...

Страница 10: ...ct the tube to the fitting the following actions should be done u Insert the white tube until it stops in the hole of the fitting If the connection is right then the tube enters the fitting hole by 15...

Страница 11: ...device 8 On off button flushing device 9 Tube for supplying tap water to the device 10 Tube of the outlet of purified water from the device Connection of diverter to the tap To install the divertor on...

Страница 12: ...them During device pay attention to the fact that the inlet and outlet tubes pass freely along radii that exclude kinks Connection of the device to the electric network The EMERALD device is connecte...

Страница 13: ...gin without proper pre filtration and disinfection Cold tap water supply to the device Fig 10 Water supply using the regulator on the diverter To enable the device in the OPERATION mode it is necessar...

Страница 14: ...RATION mode and the drinking water quality has returned to normal Some features of the OPERATION mode u If the STANDBY mode idle of the device is less than 8 hours then when it is turned on the green...

Страница 15: ...y 4 months or after 1 200 liters of the purified water whichever comes earlier The EMERALD automatically monitors the volume of purified water and it notifies you about the need for flushing u After 8...

Страница 16: ...device back into the flushing device Maintenance of the EMERALD device is carried out in accordance with the diagram on Fig 11 Preparation of citric acid washing solution To carry out the flushing pro...

Страница 17: ...nnections must be securely locked The device must be in STANDBY mode and be connected to a power source The flushing device should be located on a flat and stable surface on the countertop next to the...

Страница 18: ...HING mode is non volatile and has priority That is when the network disappears and when it reappears the device will automatically enter the stage of the FLUSHING mode from which it was removed by dis...

Страница 19: ...ents 1 Provide the necessary pressure in the water supply line see Table 5 2 Flush the device with citric acid solution see the section MAINTENANCE OF THE DEVICE The citric acid washing solution is no...

Страница 20: ...ication corrective actions or maintenance performed by any person other than the authorized representative of the warranty service and maintenance service of the manufacturer or official trading partn...

Страница 21: ...s for refusing by the representative of the manufacturer to connect the device as well as provide with the service and warranty service In the case of self installation and service of the device the m...

Страница 22: ...ater temperature 1 30 Water supply line pressure MPa 0 1 0 4 Total mineralization of supplied tap water ppm 100 350 pH of supplied tap water 6 9 Efficiency of anodic oxidation of bivalent iron ions wi...

Страница 23: ...MERALD HOME 4 device 1 2 Power supply adapter 1 3 Network cable for power supply 1 4 Diverter for water tap with a set of nozzles 1 5 Flushing device with a set of hoses 1 6 Set of connecting tubes 1...

Страница 24: ...acture the EMERALD as well as to provide them with service and warranty service EMERALD ECOTECHNOLOGIES LLC has the exclusive right to transfer to its official trading partners all the necessary power...

Страница 25: ...24 APPENDIX No 1 CERTIFICATES 1 CERTIFICATE OF CONFORMITY OF QUALITY MANAGEMENT SYSTEM REQUIREMENTS GOST R ISO 9001 2015 ISO 9001 2015 2 CERTIFICATE OF CONFORMITY OF THE EAC CUSTOMS UNION...

Страница 26: ...25 3 EXPERTS REPORT ISSUED BY ROSPOTREBNADZOR...

Страница 27: ...26 4 VOLUNTARY CERTIFICATE OF COMPLIANCE WITH GOST R 5 DECLARATION OF COMPLIANCE WITH EAC OF THE CUSTOMS UNION...

Отзывы: