background image

 

 

14 

7.

 

MAINTENANCE OF THE DEVICE. 

 
To achieve the highest quality of purified water in the EMERALD as well as to ensure the regulatory 
compliance of water quality the user shall regularly flush the device with the solution of citric acid. 
With timely and uncomplicated maintenance your device will produce the highest quality drinking 
water with excellent taste characteristics for many years. 
 
Important!  The  EMERALD  does  not  require  the  consumables  materials  and  high-wear  parts.  The 
electrochemical module and the auxiliary filtering elements (catalytic filter and electrokinetic filter) 
do not require the periodic replacement while observing the operating rules described above. 
 
Maintenance  of  the  EMERALD  including  the  regular  flushing  of  the  entire  device  (including  the 
electrochemical module and filter elements) with the solution of citric acid to remove the accumulated 
impurities and deposits. The regularity of maintenance of the EMERALD depends on the quality of 
the primary water, the usage rate and it is also based on user’s experience. At the average when using 
the drinking water from the municipal water supply devices the maintenance of the device shall be 
carried out at least once every 4 months or after 1,200 liters of the purified water (whichever comes 
earlier). 
 
The EMERALD automatically monitors the volume of purified water and it notifies you about the 
need for flushing: 

u

 

After 8 hours

 of working in the OPERATION mode the LED will light in orange (≈480 liters 

of the purified water) indicating that the device is DESIRABLE to flush with the citric acid 
solution. 

u

 

After 10 hours

 of working in the OPERATION mode (≈ 600 liters of the purified water) the 

LED will light in red indicating that the Unit MUST be flushed out with the citric acid solution. 
 

Important!

 The flushing frequency is calculated for the tap water with average salinity of 

200 ppm. For regions with the excessive water hardness (mineralization of more than 350 ppm) 
it is necessary to use the water softener filter (purchased separately) or to perform more frequent 
flushing  of  the  device  with  the  citric  acid.  The  regularity  of  the  flushing  in  this  case  is 
determined in situ depending on the hardness of the supplied tap water, the operating mode of 
the device and the organoleptic qualities of the purified water.  

 
* If during the operation of the device after a series of flushes it seems to you that the taste of 

purified water does not suit you it is possible to purchase and replace the filter elements of the device. 
The order can be placed with your nearest dealer or at the official website of the manufacturer. 
 

 

Содержание Home 4

Страница 1: ...PASSPORT AND OPERATION MANUAL EMERALD HOME 4 FOR PURIFICATION AND ELECTRIAL TREATMENT OF FRESH WATER...

Страница 2: ...e connection above the sink 10 Connection of diverter to the tap 10 Connection of the device to the electric network 11 6 OPERATION OF THE DEVICE 12 Cold tap water supply to the device 12 LED indicati...

Страница 3: ...e nature Reproducing the most complex natural processes of water purification and treatment has become possible due to the creation of highly reliable electrochemical modules which are the main elemen...

Страница 4: ...the water in the form of aerosol to moisturize the skin Moisturizing masks with the use of antioxidant water will have the special effect Pets and Plants the pets will prefer the antioxidant water to...

Страница 5: ...re ac celerated tens of thousands of times due to the use of the latest technologies and electrochemical modules The catalytic and electrokinetic filters work in purity They are located after the anod...

Страница 6: ...ified from free chlorine and chlororganic compounds u Improves the taste of water and eliminates the unpleasant odors due to the anodic removal of phenols and hydrogen sulfide Fig 3 Cathodic chamber o...

Страница 7: ...thorized service center In order to reduce the risk of fire or electric shock it is strongly recommended not to disassemble the electronic components of the device u Avoid the rough handling with the...

Страница 8: ...er elements and the electro chemical module is required see the section MAINTENANCE OF THE DEVICE u Do not use the first 30 liters of purified water immediately after connecting the device or after wa...

Страница 9: ...and the parts included in the kit to connect the device in accordance with the diagram in Fig 7 ATTENTION Before starting the device connec tion procedure be sure to familiarize yourself with the bas...

Страница 10: ...ct the tube to the fitting the following actions should be done u Insert the white tube until it stops in the hole of the fitting If the connection is right then the tube enters the fitting hole by 15...

Страница 11: ...device 8 On off button flushing device 9 Tube for supplying tap water to the device 10 Tube of the outlet of purified water from the device Connection of diverter to the tap To install the divertor on...

Страница 12: ...them During device pay attention to the fact that the inlet and outlet tubes pass freely along radii that exclude kinks Connection of the device to the electric network The EMERALD device is connecte...

Страница 13: ...gin without proper pre filtration and disinfection Cold tap water supply to the device Fig 10 Water supply using the regulator on the diverter To enable the device in the OPERATION mode it is necessar...

Страница 14: ...RATION mode and the drinking water quality has returned to normal Some features of the OPERATION mode u If the STANDBY mode idle of the device is less than 8 hours then when it is turned on the green...

Страница 15: ...y 4 months or after 1 200 liters of the purified water whichever comes earlier The EMERALD automatically monitors the volume of purified water and it notifies you about the need for flushing u After 8...

Страница 16: ...device back into the flushing device Maintenance of the EMERALD device is carried out in accordance with the diagram on Fig 11 Preparation of citric acid washing solution To carry out the flushing pro...

Страница 17: ...nnections must be securely locked The device must be in STANDBY mode and be connected to a power source The flushing device should be located on a flat and stable surface on the countertop next to the...

Страница 18: ...HING mode is non volatile and has priority That is when the network disappears and when it reappears the device will automatically enter the stage of the FLUSHING mode from which it was removed by dis...

Страница 19: ...ents 1 Provide the necessary pressure in the water supply line see Table 5 2 Flush the device with citric acid solution see the section MAINTENANCE OF THE DEVICE The citric acid washing solution is no...

Страница 20: ...ication corrective actions or maintenance performed by any person other than the authorized representative of the warranty service and maintenance service of the manufacturer or official trading partn...

Страница 21: ...s for refusing by the representative of the manufacturer to connect the device as well as provide with the service and warranty service In the case of self installation and service of the device the m...

Страница 22: ...ater temperature 1 30 Water supply line pressure MPa 0 1 0 4 Total mineralization of supplied tap water ppm 100 350 pH of supplied tap water 6 9 Efficiency of anodic oxidation of bivalent iron ions wi...

Страница 23: ...MERALD HOME 4 device 1 2 Power supply adapter 1 3 Network cable for power supply 1 4 Diverter for water tap with a set of nozzles 1 5 Flushing device with a set of hoses 1 6 Set of connecting tubes 1...

Страница 24: ...acture the EMERALD as well as to provide them with service and warranty service EMERALD ECOTECHNOLOGIES LLC has the exclusive right to transfer to its official trading partners all the necessary power...

Страница 25: ...24 APPENDIX No 1 CERTIFICATES 1 CERTIFICATE OF CONFORMITY OF QUALITY MANAGEMENT SYSTEM REQUIREMENTS GOST R ISO 9001 2015 ISO 9001 2015 2 CERTIFICATE OF CONFORMITY OF THE EAC CUSTOMS UNION...

Страница 26: ...25 3 EXPERTS REPORT ISSUED BY ROSPOTREBNADZOR...

Страница 27: ...26 4 VOLUNTARY CERTIFICATE OF COMPLIANCE WITH GOST R 5 DECLARATION OF COMPLIANCE WITH EAC OF THE CUSTOMS UNION...

Отзывы: