background image

 

 

5.

 

CONNECTION OF THE DEVICE 

 

ATTENTION! This 

section 

describes 

the 

main 

method 

of 

connecting 

the EMERALD device above the sink, recommended by the manufacturer. If you use an alternative 
method of connecting the EMERALD device, you must make sure that the method you choose does 
not contradict other conditions of this Passport and the instruction manual. In the event of a violation 
of the device and operating conditions of the EMERALD device, claims for warranty may be rejected. 

 

EMERALD device location above the sink. 

 

The  EMERALD  device  can  be  located  without  fas-

tening on the countertop, or it can be fixed to the wall with 
screws, for which there are special suspensions on the rear 
wall of the devices’ casing ( see Fig. 5). To connect the EM-
ERALD device above the sink, you must use the connect-
ing tubes (white tube ¼ made of food-grade plastic) and the 
parts included in the kit 

to 

connect the device in accordance 

with the diagram in Fig. 7 .

 

 

 

ATTENTION! Before  starting  the  device  connec-

tion procedure, be sure to familiarize yourself with the basic 
principles of connecting a white tube to fittings described in 
the General Guidelines for Handling Quick Couplings of the 
John Guest® Type Section .

 

 

 

Connecting  an  EMERALD  device  requires  certain 

skills  in  working  with  plumbing  equipment. We  recom-
mend  using  the  services  of  authorized  specialists  of  the 
company EMERALD ECOTECHNOLOGIES LLC , a rep-
resentative of the dealer network or the services of a quali-
fied  plumber-plumber  of  the  housing  and  communal  ser-

vices organization at your place of residence. Do not install the device in a place where its maintenance 
will be difficult.

 

 

 

Before connecting, turn off the cold water tap and then open the cold water tap on the kitchen 

faucet to relieve pressure in the pipe. Avoid direct sunlight on the surface of the device enclosure.

 

 

 

Fig. 5 EMERALD device option for wall 
mounting near the sink  . 

 

Содержание Home 4

Страница 1: ...PASSPORT AND OPERATION MANUAL EMERALD HOME 4 FOR PURIFICATION AND ELECTRIAL TREATMENT OF FRESH WATER...

Страница 2: ...e connection above the sink 10 Connection of diverter to the tap 10 Connection of the device to the electric network 11 6 OPERATION OF THE DEVICE 12 Cold tap water supply to the device 12 LED indicati...

Страница 3: ...e nature Reproducing the most complex natural processes of water purification and treatment has become possible due to the creation of highly reliable electrochemical modules which are the main elemen...

Страница 4: ...the water in the form of aerosol to moisturize the skin Moisturizing masks with the use of antioxidant water will have the special effect Pets and Plants the pets will prefer the antioxidant water to...

Страница 5: ...re ac celerated tens of thousands of times due to the use of the latest technologies and electrochemical modules The catalytic and electrokinetic filters work in purity They are located after the anod...

Страница 6: ...ified from free chlorine and chlororganic compounds u Improves the taste of water and eliminates the unpleasant odors due to the anodic removal of phenols and hydrogen sulfide Fig 3 Cathodic chamber o...

Страница 7: ...thorized service center In order to reduce the risk of fire or electric shock it is strongly recommended not to disassemble the electronic components of the device u Avoid the rough handling with the...

Страница 8: ...er elements and the electro chemical module is required see the section MAINTENANCE OF THE DEVICE u Do not use the first 30 liters of purified water immediately after connecting the device or after wa...

Страница 9: ...and the parts included in the kit to connect the device in accordance with the diagram in Fig 7 ATTENTION Before starting the device connec tion procedure be sure to familiarize yourself with the bas...

Страница 10: ...ct the tube to the fitting the following actions should be done u Insert the white tube until it stops in the hole of the fitting If the connection is right then the tube enters the fitting hole by 15...

Страница 11: ...device 8 On off button flushing device 9 Tube for supplying tap water to the device 10 Tube of the outlet of purified water from the device Connection of diverter to the tap To install the divertor on...

Страница 12: ...them During device pay attention to the fact that the inlet and outlet tubes pass freely along radii that exclude kinks Connection of the device to the electric network The EMERALD device is connecte...

Страница 13: ...gin without proper pre filtration and disinfection Cold tap water supply to the device Fig 10 Water supply using the regulator on the diverter To enable the device in the OPERATION mode it is necessar...

Страница 14: ...RATION mode and the drinking water quality has returned to normal Some features of the OPERATION mode u If the STANDBY mode idle of the device is less than 8 hours then when it is turned on the green...

Страница 15: ...y 4 months or after 1 200 liters of the purified water whichever comes earlier The EMERALD automatically monitors the volume of purified water and it notifies you about the need for flushing u After 8...

Страница 16: ...device back into the flushing device Maintenance of the EMERALD device is carried out in accordance with the diagram on Fig 11 Preparation of citric acid washing solution To carry out the flushing pro...

Страница 17: ...nnections must be securely locked The device must be in STANDBY mode and be connected to a power source The flushing device should be located on a flat and stable surface on the countertop next to the...

Страница 18: ...HING mode is non volatile and has priority That is when the network disappears and when it reappears the device will automatically enter the stage of the FLUSHING mode from which it was removed by dis...

Страница 19: ...ents 1 Provide the necessary pressure in the water supply line see Table 5 2 Flush the device with citric acid solution see the section MAINTENANCE OF THE DEVICE The citric acid washing solution is no...

Страница 20: ...ication corrective actions or maintenance performed by any person other than the authorized representative of the warranty service and maintenance service of the manufacturer or official trading partn...

Страница 21: ...s for refusing by the representative of the manufacturer to connect the device as well as provide with the service and warranty service In the case of self installation and service of the device the m...

Страница 22: ...ater temperature 1 30 Water supply line pressure MPa 0 1 0 4 Total mineralization of supplied tap water ppm 100 350 pH of supplied tap water 6 9 Efficiency of anodic oxidation of bivalent iron ions wi...

Страница 23: ...MERALD HOME 4 device 1 2 Power supply adapter 1 3 Network cable for power supply 1 4 Diverter for water tap with a set of nozzles 1 5 Flushing device with a set of hoses 1 6 Set of connecting tubes 1...

Страница 24: ...acture the EMERALD as well as to provide them with service and warranty service EMERALD ECOTECHNOLOGIES LLC has the exclusive right to transfer to its official trading partners all the necessary power...

Страница 25: ...24 APPENDIX No 1 CERTIFICATES 1 CERTIFICATE OF CONFORMITY OF QUALITY MANAGEMENT SYSTEM REQUIREMENTS GOST R ISO 9001 2015 ISO 9001 2015 2 CERTIFICATE OF CONFORMITY OF THE EAC CUSTOMS UNION...

Страница 26: ...25 3 EXPERTS REPORT ISSUED BY ROSPOTREBNADZOR...

Страница 27: ...26 4 VOLUNTARY CERTIFICATE OF COMPLIANCE WITH GOST R 5 DECLARATION OF COMPLIANCE WITH EAC OF THE CUSTOMS UNION...

Отзывы: