General Installation Recommendations
Installation
IND100078-49
8. Information about necessary pull-relievers for cables is indicated in the Physical Connection section of this manual.
Attention must be paid to this information so that cable breaks will not occur, e.g. during service work.
9. Do not paint the product. The surface treatment influences the excess heat transfer. Painting, labels or other
surface treatments that differ from the factory default, might cause overheating.
10. Exposure to heavy vibration and acoustic noise might under certain circumstances affect functionality and expected
lifetime. This must be considered during system assembly and installation. Mounting position must be carefully
selected to avoid any exposure of amplified vibration.
11. Additional rules may apply to certain procedures where the symbols and are present. For more
information, review “IEC62368 policy for Hatteland Technology product” section later in this manual.
Installation limitations
Due to environmental factors, please review the points noted below.
A: Overheat prevention:
For Maritime Multi Computer (MMC, Panel Computers) it is advised that you do not mount the unit in a
vertical angle lower than ±30 degrees, as noted in point 3 (previous section), i.e. flat mounting of the unit.
This is to prevent both overheating the unit as well as ensure proper cooling airflow to sustain long-life and
stable operation. Panel Computer units generate more heat than regular Display units naturally because of
CPU and mainboard chips.
B: Glass Display Control™ (GDC) front glass touch buttons:
As this uses Projected Capacitive technology (instead of conventional hard physical buttons and knobs),
the touch controller can react and is sensitive to raindrops (for outdoor installations). To ensure that
raindrops do not stay on the unit’s flat glass surface, please do not mount the unit in a vertical angle lower
than ±30 degrees, i.e. flat mounting of the unit. This is to prevent accidental touches that are similar to a
human finger (cover area for a x period of seconds) as well as make sure the raindrops are “moving” and
runs down off the glass surface.
For Maritime Multi Display (MMD) units (not available for Panel Computers (MMC) units), the angle could
potentionally be lower as the On Screen Display (OSD) menu offers a "OSD Key utdoor" function with 5
seconds delay before activation on front glass functions. Please review the "OSD Menu Functions" to
learn more. In certain situations this might help, but is only suggested as a trouble-shooting tip during
installation or during short-term observer use if found suitable. It should not be considered as a defintive
trusted solution.
C: Projected Capacitive Technology (PCTouch) MULTITOUCH and in general Touch Screen glass:
For all units with a factory mounted touch screen and for outdoor use especially, please review point B above
regarding standing raindrops. The only solution to this situation is not to mount the unit in a vertical angle lower
than ±30 degrees, i.e. flat mounting of the unit to ensure touch screen is not activated and accidentally
automatically chooses functions in your running chart, radar or other software installed.
D: General rule for console mounted units:
To ensure proper cooling airflow, long-life and stable operation for all units, please make sure that the
console casing has either fans or decent ventilation holes to prevent overheating inside the console due to
the combined temperature of both Display or Panel Computer units together with other electronic instruments.
A general rule is to make sure the console casing is capable of expelling “worst case scenario” in respect of
the “Max Power Consumption” of all devices installed. Please review also point 2, 5, 6 and 9 (previous
section) for additional information and installation tips.
Содержание Hatteland HD 19T22
Страница 7: ...7 This page left intentionally blank...
Страница 10: ...10 This page left intentionally blank...
Страница 11: ...11 General...
Страница 21: ...21 Installation...
Страница 42: ...42 This page left intentionally blank...
Страница 43: ...43 Operation...
Страница 46: ...46 This page left intentionally blank...
Страница 47: ...47 Specifications...
Страница 64: ...64 This page left intentionally blank...
Страница 65: ...65 Specifications Accessories...
Страница 69: ...69 Technical Drawings...
Страница 74: ...74 This page left intentionally blank...
Страница 75: ...75 Technical Drawings Accessories...
Страница 111: ...111 Appendixes...
Страница 140: ...140 Appendix IND100077 24 User Notes...
Страница 142: ...Hatteland Technology AS www hattelandtechnology com Enterprise no NO974533146...