DATASHEET
Hatteland Technology AS | www.hattelandtechnology.com | Enterprise no: NO974533146
1/4
4 channel RS-422 / RS-485, NMEA / IEC COM Module
Manufacturer:
Hatteland Technology AS
Product:
4 channel RS-422 / RS-485 COM module
Typenumber:
PCA100293-1
Last Revised:
16 Apr 2020
Revision#:
27
The Hatteland Technology COM modules provide the system with quad independent COM channels. The module is attached to the
motherboard via standard USB interface. Application software access the COM channels as standard COM devices, i.e. in the normal case
is there no requirements for additional software development. This module will mainly be integrated, electrical and mechanical, in the final
products, such as; Series X G1/G2 Panel Computers and selected Stand-alone Computers.
Description:
Internal USB to RS-485 / RS-422 isolated
• Features
- Independent channels (If card is replaced most OS will not change COM port number).
- Outputs are short circuits protected. Inputs are protected.
- Driver strength are approved.
- All channels is fully isolated, channel to channel and channel to chassis.
- Classified towards IEC61162-1 and IEC61162-2.
- Tested according to EN61162.
- NMEA-183 Compliant.
- All requirement for usage in ECDIS applications/systems is fulfilled.
• Absolute Max voltage applied to outputs
-8V to +13V
• Data Rate / Technical Data Output
- Outputs 230kbps (Theoretically 400kbps).
- ±15kV ESD protection on all RS-485 signals. (Human Body Model - HBM)
- Isolation rating = 2000VRMS, not intended for connection to live power nets.
• Transmitter enable mode
- Standard mode is automatic.
- Standard Mode will accept send by RTS, but will in fact ignore RTS.
- Each channel have a overide jumper
*
which can be used to force the transmitter to
always be active. See below and next page for details.
• Cable Connector
Terminal Block 5-pin rows (MC 1,5/ 5-STF-3,81) (see illustration below)
• Recommended Cable Thickness
Minimum 22 AWG - Maximum 18 AWG
• Power Consumption
Max 347mA @ 5V
• Supported Operating Systems (OS)
Embedded Enterprise (WEE):
Microsoft® Windows® Server 2003/2008/2008R2 (Eng),
Microsoft® Windows® 2003/2008/2008R2 (Eng), Microsoft® Windows® 7 Professional/
Ultimate (Eng, SP1), Windows® 10 IoT Enterprise 2016 LTSB.
Linux:
Generic support for Kernel 3.0.0.19 or newer
• Drivers
"https://www.hattelandtechnology.com/hubfs/pdf/misc/doc102080-1_usb-com_module_configuration.pdf"
"https://www.hattelandtechnology.com/hubfs/drivers/ht00262opt-a1_drivers.zip"
"https://www.hatteland-display.com/support_hardware_drivers_peripherals.php"
Linux, please visit:
http://www.ftdichip.com/Drivers/D2XX.htm
Note: Listed Operating Systems above are hardware/platform dependent. Please check datasheet for specific unit if OS is supported.
•
Test and certificate
Hatteland Technology standard,
(tested / type approved by the following classification societies):
IEC 60945 4th
(EN 60945:2002),
IACS E10
,
EU RO MR
- Mutual Recognition,
ClassNK
- Nippon Kaiji Kyokai
Note: Product below for illustration only. Location of module and product size/design may differ. Connector/pinning remain the same.
Illustration and Pinning:
4 Ports (Virtual COM) identified in the Operating System (OS):
COMx (A), COMx (B), COMx (C), COMx (D)*
*
Configuration dependent, x = next available port number(s) OS.
RS-485 Half Duplex (2-wire, supports ECHO) Configuration:
Connect TX and RX pair-wise: TX- to RX-, TX+ to RX+.
*Note: The jumper for “force of transmitter” is open by factory default. For some custom
models this jumper is preset to closed (active), in that case unit has to be opened and jumper set to open to allow Half Duplex mode.
5-pin Terminal Block 3.81
Pinout Assignments
69
IND100241-13
Appendix
5-pin Digital Output Module
“Safety Signal Relay”
3 A
X1
DIG
OUT
1 2 3 4 5
PIN 01 X1 - Out:
011
COM (Common
Center Terminal)
PIN 02 X1 - N/C
Not Connected
Not in use
PIN 03 X1 - Out:
014
NO (Normally Open)
PIN 04 X1 - N/C
Not Connected
Not in use
PIN 05 X1 - Out:
012
NC (Normally Closed)
4+4 pin CAN I/O Module, 2 channels
Type Number “HT 00254 OPT-A1”
3 A B
X8
CAN1
X9
CAN2
1 2 3 4
1 2 3 4
Pin 01 X8 - Can1:
081
In Low
Pin 02 X8 - Can1:
082
Out Low
Pin 03 X8 - Can1:
083
In High
Pin 04 X8 - Can1:
084
Out High
Pin 01 X9 - Can2:
091
In Low
Pin 02 X9 - Can2:
092
Out Low
Pin 03 X9 - Can2:
093
In High
Pin 04 X9 - Can2:
094
Out High
8-pin Digital Output / Input Module
“Solid State Relay”
3 A
X1
DIG
OUT
X1
DIG
IN
1 2 3 4
1 2 3 4
Pin 01 X1 - Out:
041
Out +
Pin 02 X1 - Out:
042
Out -
Pin 03 X1 - Out:
031
COM (Common Center
Terminal) *
Pin 04 X1 - Out:
032
NO (Normally Open)*
* IEC 60950 Compliant, 48VDC
Pin 01 X1 - In:
052
+24VDC
Pin 02 X1 - In:
053
GND (Ground)
Pin 03 X1 - In:
061
+24VDC
Pin 04 X1 - In:
062
+Input
10-pin Digital Output / Input & Serial Module
“Mechanical Relay &
COM (isolated RS-422/485)
”
3 A
X1
DIG
OUT
X7
SER
I/O
1 2 3 4 5
1 2 3 4 5
PIN 01 X1 - Out:
021
COM (Common Center
Terminal)
PIN 02 X1 - N/C
Not Connected / Not used
PIN 03 X1 - Out:
024
NO (Normally Open)
PIN 04 X1 - N/C
Not Connected / Not used
PIN 05 X1 - Out:
022
NC (Normally Closed)
PIN 01 X7 - In:
71
Rx+ (Receive Data +)
PIN 02 X7 - In:
72
Rx- (Receive Data -)
PIN 03 X7 - Out:
73
Tx+ (Transmit Data +)
PIN 04 X7 - Out:
74
Tx- (Transmit Data -)
PIN 05 X7 - GND:
75
SGnd (Signal Ground)
10+10 pin RS-422 / RS-485 NMEA Module
Type Number “PCA100293-1”
3 A B
6 7 8 9 10
1 2 3 4 5
6 7 8 9 10
1 2 3 4 5
PIN 01 TxD- Transmit Data Negative
PIN 02 TxD+ Transmit Data Positive
PIN 03 GND Isolated Ground
PIN 04 RxD- Receive Data Negative
PIN 05 RxD+ Receive Data Positive
PIN 06 TxD- Transmit Data Negative
PIN 07 TxD+ Transmit Data Positive
PIN 08 GND Isolated Ground
PIN 09 RxD- Receive Data Negative
PIN 10 RxD+ Receive Data Positive
RS-485 Half Duplex (2-wire) Confi guration:
Connect TX and RX pair-wise:
TX- to RX-, TX+ to RX+.
*Note: The jumper for “force of transmitter” is
open by factory default. For some custom
models this jumper is preset to closed (active),
in that case unit has to be opened and jumper
set to open to allow Half Duplex mode.
10-pin RS-422 / RS-485 Module
“RS-422/RS-485 SCOM Buzzer”
1
2 B
2 4 6 8 10
1 3 5 7 9
PIN 01* RxD+ Receive Data Positive
PIN 02 GND Ground
PIN 03* RxD- Receive Data Negative
PIN 04 +5V
+5V Out
PIN 05* TxD+ Transmit Data Positive
PIN 06 BUZ- Buzzer Control Negative
PIN 07* TxD-
Transmit Data Negative
PIN 08 BUZ+ Buzzer Control Positive
PIN 09 GNDR
Ground 100Ω
PIN 10 GND Ground
*Pin 1,3,5,7 = RS-485 Full Duplex (4-wire)
*Pin 5,7 = RS-485 Half Duplex (2-wire)
Содержание Hatteland E Series
Страница 8: ...8 This page left intentionally blank...
Страница 9: ...9 General...
Страница 17: ...17 Installation...
Страница 41: ...41 Operation...
Страница 44: ...44 This page left intentionally blank...
Страница 45: ...45 Specifications...
Страница 61: ...61 Specifications Accessories...
Страница 65: ...65 Technical Drawings...
Страница 70: ...70 This page left intentionally blank...
Страница 71: ...71 Technical Drawings Accessories...
Страница 88: ...88 This page left intentionally blank...
Страница 89: ...89 Appendixes...
Страница 134: ...134 Appendix IND100077 24 User Notes...
Страница 136: ...Hatteland Technology AS www hattelandtechnology com Enterprise no NO974533146...