background image

 

EXAMPLE 
If you start 

SSCmini

®

 at 9:00 and set the work schedule at 5, then the unit will be working from 9:00 to 

9:30 (

Normal operation

 LED is ON) and in stand-by mode from 9:30 to 10:00 (

Stand-by

 LED is ON).   

 

 

 
 
A new cycle will start at 10:00 until 10:30, and so on. 
 

 

 
 
 
If  you  activate  Superchlorination  mode  at  10:30  (

Superchlorination

  LED  is  ON),  then  the  unit  will  be 

working  until  10:30  of  the  next  day  and  will  exit  Superchlorination  mode  afterwards.  Once  finished 
Superchlorination, the schedule will be restored and a new cycle will start.   

 

 

 
 

 

 

 

 

 

09:00 – 09:30 

09:30 – 10:00 

10:00 – 10:30 

10:30 – next day 10:30 

Содержание SSC mini

Страница 1: ...1 SALT CHLORINATOR USER MANUAL SSCmini...

Страница 2: ...side the wiring compartment To reduce the risk of electric shock this terminal must be connected to the grounding means provided in the electric supply service panel with a continuous copper wire equi...

Страница 3: ...acteria the above reactions will continuously recycle virtually eliminating the need to add sanitizing chemicals to your pool The only time you may need to add more salt to the pool is when water is r...

Страница 4: ...lkalinity 80 120 ppm Calcium Hardness 200 400 ppm Metal 0 ppm 6 1 SALT LEVEL The amount of salt required when using Emaux SSCmini is between 4000 and 6000 ppm To reach this concentration it is necessa...

Страница 5: ...enclosure that is suitable for outdoor mounting IPX4 rating However the following points must be taken into consideration for a correct installation of the control unit 1 Install the Control Unit usi...

Страница 6: ...ed in a vertical position 8 START UP Before starting up Emaux SSCmini unit the following points have to be taken into consideration 1 Check if the filter is completely clean and ensure that the swimmi...

Страница 7: ...ng guide Chapter 12 3 Alarm The unit is not working properly Refer to the Troubleshooting guide Chapter 12 4 Stand by The unit is in between operation cycles 5 Normal operation Electrolytic cell is ge...

Страница 8: ...LED is ON A new cycle will start at 10 00 until 10 30 and so on If you activate Superchlorination mode at 10 30 Superchlorination LED is ON then the unit will be working until 10 30 of the next day a...

Страница 9: ...ebris which has passed through the filter and caught on the plates 3 Try to remove the scale using a plastic or wooden tool do NOT use metal as this will scratch the coating off the plates If the scal...

Страница 10: ...pply Disconnect the unit from power supply for two minutes and then connect it again Ensure that SSCmini is receiving 220V 240VAC 50 60H input LED 4 Water temperature out of working range Test water t...

Страница 11: ...equipment or installation type 4 Damage due to unauthorized product modifications or failure to use Emaux original replacement parts 5 Damage caused by negligence or failure to properly maintain produ...

Страница 12: ...chnical operations Emaux is not liable for any loss of time inconvenience incidental expenses such as labor cost phone calls legal cost or material cost incurred in connection with the replacement or...

Отзывы: