7.2  ELECTROLYTIC CELL INSTALLATION   

 

Please follow the recommendations below to install the electrolytic cell properly: 
1.

 

The electrolytic cell should be mounted once the installation of all other swimming pool equipment 
is completed (filtration pump, filter, heating system). 

2.

 

The electrolytic cell is designed to install in PVC pool plumbing. The opening of the cell holder must 
be placed upright to enable the maintenance of titanium plates. To install the cell, cut off at least 
187mm of pipe. Fix the electrolytic holder on the pipe, put the electrodes into the cell. Make the 
electrode cable go through the nut (Figure 3). 

3.

 

Connect the unions to the pipe and make necessary adjustments for a proper connection. Once 
adjusted, fix the connection with PVC glue and tighten the union nuts.   

4.

 

Fix the electrodes inside the holder and tighten the nut of the cell; connect the electrode cable to the 
control unit; tighten the nut to ensure the good contact (Figure 4). 

 
 

 
 
 
 
 
 
 
 
 
 
 
 

Note: the cell can also be installed in a vertical position.   

 

8.

 

START-UP 

 
Before starting up Emaux 

SSCmini

®

 

unit, the following points have to be taken into consideration: 

1.

 

Check if the filter is completely clean, and ensure that the swimming pool and the installation do not 
contain any metals dissolved or algae. 

2.

 

Ensure that the heating equipment (if any) is suitable for use in salt water. 

3.

 

Ensure that chemical parameters of pool water are within the recommended range (see Chapter 6). 

4.

 

Run your filtration system for 24 hours before starting salt chlorinator so that salt in the swimming pool 
is completely dissolved.   

 
For start-up, set the system at 50% of working time. It will take a few days of adjustments to find the most 
appropriate setting according to the chlorine demand of your swimming pool. Once determined, only minor 
adjustments might be necessary in cases of splashing, backwashing, rain, etc.   
 
The temperature of the water is a parameter that effects the chlorine production. When the temperature rises, 
chlorine will be easily volatilized affecting sanitizing effect. The water temperature should be within the range 
of 15-40ºC. The Emaux 

SSCmini

®

 will not produce chlorine at temperatures below 10º C. 

Figure 4 

Figure 3 

Содержание SSC mini

Страница 1: ...1 SALT CHLORINATOR USER MANUAL SSCmini...

Страница 2: ...side the wiring compartment To reduce the risk of electric shock this terminal must be connected to the grounding means provided in the electric supply service panel with a continuous copper wire equi...

Страница 3: ...acteria the above reactions will continuously recycle virtually eliminating the need to add sanitizing chemicals to your pool The only time you may need to add more salt to the pool is when water is r...

Страница 4: ...lkalinity 80 120 ppm Calcium Hardness 200 400 ppm Metal 0 ppm 6 1 SALT LEVEL The amount of salt required when using Emaux SSCmini is between 4000 and 6000 ppm To reach this concentration it is necessa...

Страница 5: ...enclosure that is suitable for outdoor mounting IPX4 rating However the following points must be taken into consideration for a correct installation of the control unit 1 Install the Control Unit usi...

Страница 6: ...ed in a vertical position 8 START UP Before starting up Emaux SSCmini unit the following points have to be taken into consideration 1 Check if the filter is completely clean and ensure that the swimmi...

Страница 7: ...ng guide Chapter 12 3 Alarm The unit is not working properly Refer to the Troubleshooting guide Chapter 12 4 Stand by The unit is in between operation cycles 5 Normal operation Electrolytic cell is ge...

Страница 8: ...LED is ON A new cycle will start at 10 00 until 10 30 and so on If you activate Superchlorination mode at 10 30 Superchlorination LED is ON then the unit will be working until 10 30 of the next day a...

Страница 9: ...ebris which has passed through the filter and caught on the plates 3 Try to remove the scale using a plastic or wooden tool do NOT use metal as this will scratch the coating off the plates If the scal...

Страница 10: ...pply Disconnect the unit from power supply for two minutes and then connect it again Ensure that SSCmini is receiving 220V 240VAC 50 60H input LED 4 Water temperature out of working range Test water t...

Страница 11: ...equipment or installation type 4 Damage due to unauthorized product modifications or failure to use Emaux original replacement parts 5 Damage caused by negligence or failure to properly maintain produ...

Страница 12: ...chnical operations Emaux is not liable for any loss of time inconvenience incidental expenses such as labor cost phone calls legal cost or material cost incurred in connection with the replacement or...

Отзывы: