PARAMETER CONFIGURATION
Parameters can be reconfigured, and the procedure can be performed after
the “entrance panel” ID code has been allocated to the electronic units. The
procedure in question is suitable for all electronic units, Master and Slave
alike. During programming, the electronic unit switches to engaged status
and cannot be used for normal operation of the system.
Note
: if the timeout period of 30 s is exceeded, the electronic unit will exit
programming mode, and the steps must be repeated.
The timeout period is extended by 30 s every time a button is pressed.
Parameters
The configuration can be changed using the buttons on the electronic unit,
ZLWKSURJUDPPHUDUW&RUZLWKLQWHUIDFHDUW,8FRQQHFWHGWRD3&
on which the SaveProg software has been installed.
PARAMETER CONFIGURATION
Changes are made connecting one electronic unit at a time.
In systems with several electronic units, one unit must be identified as a
MASTER
and the other units as
SLAVE
units, regardless of model or type
(alphanumeric, buttons, landing). All entrance panels are supplied with the
electronic unit set as
MASTER
(ID = 1).
In the case of alphanumeric units, the
MASTER
or
SLAVE
setting is establi-
shed when programming the ID code of the electronic unit with the relative
software.
PROCEDURE FOR ACCESSING PARAMETER CONFIGURATION MODE
- Power up the electronic unit, or press the RESET button if the electronic
unit has already been installed and configured.
- At power-up or reset, the electronic unit assigned as
MASTER
searches
the system for any other electronic units installed, displaying this message:
¿JXUH
Wait for the electronic unit to return to at-rest status, displaying the message:
Press and hold the
R
button, and press
4
GHI
.
- Release both buttons.
- enter the default password
6
MNO
5
JKL
4
GHI
3
DEF
2
ABC
1
- Every time a button is pressed there will be a short “beep”, an asterisk “*”
appears on the display, and there are a further 25 seconds (timeout) in
which to press the next button. If the timeout is allowed to elapse without
pressing any button, the electronic unit will exit programming mode.
- After entering the password, press the button
. If the password is
correct, the electronic unit goes into parameter configuration mode and
displays a message of this type:
after 2s approximately, this message will appear:
NOTE: if the password is wrong, the electronic unit exits the procedure and
reverts to at-rest status. The operation must be repeated.
Having accessed the configuration procedure, the first message to appear is
a prompt to select the language
1.0
Message language
.
Use the
,
end
R
buttons to navigate the parameters menu,
the
button to confirm changes, and the
button to cancel changes.
Line 1 of the display normally shows the
current parameter
and line 2
shows the
value
to be
assigned
to the
parameter
.
¿JXUH
¿JXUH
¿JXUH
During the configuration procedure, no more than about 30s (timeout) must
elapse without any button being pressed. If this time limit is exceeded, the
electronic unit will exit programming mode.
NOTE: the information shown between square brackets refers to data of
the “Plus Two Wire system”.
NOTE: in figure 7, the letter
V
after 13F4 or 13F7 denotes
VERTICAL BUS
configuration. The letter
H
denotes
HORIZONTAL BUS
(see section on
configurations “1.2 INSTALLATION”)
RESET AND INITIALIZATION PROCEDURES
Hardware configuration allows the user to clear the EEPROM of the electro-
nic unit entirely, to indicate whether or not there is a camera installed and
detect the audio section of the electronic unit, and to interface with a PC for
the purposes of configuration using software.
HARDWARE CONFIGURATION “RESET, CLEAR EEPROM, SETTINGS”
- Press
the
RESET
button
- Within 2 seconds of pressing RESET, press the
and
buttons
simultaneously and hold.
- After 2 seconds, the following messages will be shown in alternation on
the first line of the display.
The number on line 2 will be different each time.
- Clear
EEPROM
To clear the EEPROM, enter the number displayed on line 2, then press
. After clearing the memory, the electronic unit restarts and reverts
automatically to at-rest status.
- Change electronic unit setting
Press the
button and select one of the following items using the
and
buttons.
- MONITOR PACKETS
'HGLFDWHGIRUDUW,,8DQG3&
Alongside the parameter, press
1
for YES and
0
+
for NO. To exit
programming mode, press
R
.
INDOOR UNIT ID CODES
An unambiguous ID code can be attributed to each indoor unit. The opera-
tion of allocating ID codes must be carried out from the MASTER electronic
unit. During this procedure the MASTER electronic unit communicates with
the appliance being configured, and if this is a video entryphone appliance,