27
4.9
Self-start sequence. 1
5.1
Enabled time codes
5.2
First Call Time
5.0
Clock
5.3
Last call Time
5.4
Band 1 Mon/Fri
5.5
Device
5.6
Button 6120
4.4 COMMON LOCKS
This parameter allows the release of the lock indirectly, and at the same moment as the lock of another electronic
unit is released, from an indoor unit. Indirect release can be associated with 4 different electronic units Type the
GLJLWVVRDVWRPDNHXSDQXPEHUEHWZHHQDQG>DQG@QDPHO\WKH,'RIDQHOHFWURQLFXQLWLQWKLVLQVWDQFH
the first of four possible options) for which the lock release is dependent on the lock of the current entrance panel
being activated.
To confirm, press
. On acceptance of the command, the message “Done!” is displayed.
If the ID number is outside the permissible range, the first line of the display indicates the error by showing the
message “Over limit”.
To remove the error, enter a single ‘0’ as the ID. It is also possible to navigate from one index to another using the
and
buttons. From positin 1, press
to move to the next item of the configuration menu. Use the
R
button to skip all intermediate steps and go back to the previous item in the programming menu. Entering
QXPEHUVEHWZHHQDQG> DFWXDWRUDQG DFWXDWRUDQG@WKHSURJUDPPHG
element will not be an electronic unit, but an actuator. Number 21 identifies the first relay of the 1st actuator, number
LGHQWLILHVWKHVHFRQGUHOD\RIWKHWKDFWXDWRU8QOLNHWKHORFN)RU)DFWXDWRUVDUHQRWJRYHUQHGE\DQ\NLQG
of interlock, as described in heading 3.9 (ENABLE-INHIBIT SETTINGS). For display purposes, entrance panels
have a letter “P” prefix, and actuators a letter “A”.
COM. LOCK 1 / P1 COM. LOCK 1 / A1
4.5 - F1 COMMON
This parameter enables indirect activation of the F1 function, at the same time as the F1 function of another
electronic unit is activated, from an indoor unit. Up to 4 different electronic units can be associated in indirect
DFWLYDWLRQ(QWHUWKHQXPEHUEHWZHHQDQG>DQG@FRUUHVSRQGLQJWRWKH,'RIWKHHOHFWURQLFXQLWWKDWPXVW
EHDFWLYDWHGLQGLUHFWO\WRJHWKHUZLWKWKHHOHFWURQLFXQLWFXUUHQWO\EHLQJFRQ¿JXUHGDQGFRQ¿UPE\SUHVVLQJ
On acceptance of the command, the message “Done!” is displayed.
,IWKH,'QXPEHULVRXWVLGHWKHSHUPLVVLEOHUDQJHWKH¿UVWOLQHRIWKHGLVSOD\ZLOOVKRZWKHPHVVDJH³2YHUOLPLW´
NOTE: To remove the error, enter a single ‘0’ as the ID.
It is also possible to navigate from one index to another using the
and
buttons. From position 1, press
to move to the next item in the programming menu. Use the
R
button to skip all intermediate steps and
JREDFNWRWKHSUHYLRXVLWHPLQWKHSURJUDPPLQJPHQX(QWHULQJQXPEHUVEHWZHHQDQGWKHQWKHSURJUDP
-
PHGHOHPHQWZLOOQRWEHDQHOHFWURQLFXQLWEXWDQDFWXDWRU1XPEHULGHQWL¿HVWKH¿UVWUHOD\RIWKHVWDFWXDWRU
QXPEHULGHQWL¿HVWKHVHFRQGUHOD\RIWKHWKDFWXDWRU8QOLNHWKHORFN)RU)DFWXDWRUVDUHQRWJRYHUQHGE\
DQ\NLQGRILQWHUORFNDVGHVFULEHGLQKHDGLQJ)RUGLVSOD\SXUSRVHVHOHFWURQLFXQLWVKDYHDOHWWHU³3´SUH¿[
and actuators a letter “A”.DEFAULT:
F1 COMUNE / P1 F1 COMUNE / A1
4.6 - F2 COMMON
The procedure for configuring function F2 COMMON is the same as described in heading 4.4 for the configuration of function F1 COMMON.
4.7 - DISABLE SLAVE ENTRANCE PANEL SEARCH (AVAILABLE ONLY IF THE CURRENT ENTRANCE PANEL SETTING AT 1.1 IS ID = 1 MASTER)
This parameter can be used to disable the search for SLAVE electronic units via the MASTER electronic unit, on startup or after a system reset. Press
1
to deactivate the search, and
0
+
to activate the search. Press
to confirm the change. When the change is confirmed, the message “Done!” will appear.
Default = No
4.8 - DISABLE SELF-START (AVAILABLE ONLY IF THE CURRENT ENTRANCE PANEL SETTING AT 1.1 IS ID = 1 MASTER)
The function relates to the MASTER electronic unit, which is configured so as to inhibit self-start for all indoor units of the system.
Press
1
to deactivate self-start, and
0
+
to activate self-start. Press
to confirm the change. When the change is confirmed, the message “Done!”
will appear.
Default = No
4.9 - SELF-START SEQUENCE
Configurable only on the MASTER electronic unit (ID=1). With this parameter, the cyclical start-up of a sequence of entrance panels can be associated with
the self-start button of each indoor unit.
Use the
EXWWRQVWRVHOHFWRQHRIWKH>@SK\VLFDOFRGHVGHYLFH,'FRUUHVSRQGLQJWRDQLQGRRUXQLWDQGODVWO\WKHVZLWFKERDUGV
Note
: 945F switchboards currently do not have the self-start function. Enter the code and press
to select.
Having located the required code, press the
EXWWRQWRFKDQJHWKHYDOXH(QWHUWKHHOHFWURQLFXQLW,'FRGHRUFRGHVPD[LPXPFKDUDFWHUV>@
To enter codes for electronic units from 1 to 9, use buttons
1
to
9
WXYZ
whereas for electronic units from 10 to 15, first press button
0
+
then press one of
buttons
0
+
to
5
JKL
. When button
0
+
is pressed, a “?” appears in the display, and when pressing the next number, a letter will be inserted (A->10, B->11,
&!'!(!)!