25
Press the
button to confirm the change. After confirmation, the
electronic unit will check whether or not the name entered is already
taken by another user. If already taken, the message “..... used by ...”
will appear, and another name must be entered, otherwise the message
“Done!” will appear. If at least one name has been changed, on com-
pletion, the names will be reordered alphabetically. This process takes
about 10 seconds for a full name index.
Note
MDQLWRUVZLWFKERDUGVQXPEHUV>@KDYHD
IL[HGQDPH6ZLWFKERDUG>@6ZLWFKERDUG>@'()$8/7
BUTTON
SYMBOL
1
<spazio>1@.,:;?!()<>
2
ABC
ABC2abcÁÀÃÅÄÆÇÈáàãåäæçè
3
DEF
DEF3defïÉÈÊÌéèêì
4
GHI
GHI4ghiÍÌíì
5
JKL
JKL5jkl
6
MNO
012PQR²xÏÑ®gyz}|
7
PQRS
PQRS7pqrsRŠršß
8
TUV
TUV8tuvÚÙÜÙúùüù
9
WXYZ
WXYZ9wxyzÝZýz
0
+
0_$&*#+-=/%”’
2.8 PROGRAMMING PASSWORD
Sets the password for access to configuration from keypad. Enter the new password using buttons
0
+
to
9
WXYZ
.
Press the
button to confirm the change. When the change is confirmed, the message “Done!” will appear.
Default: 654321
2.9 ANSWER TIME
This is the interval of time, expressed in seconds, that the electronic unit waits from the end of the call signal until there is an answer from the indoor unit. If
there is no response within the “answer time”, the electronic unit disconnects the indoor unit to which the call was directed. If the indoor unit answers before
the set interval elapses, the electronic starts to count the conversation time.Enter the new time with buttons
0
+
to
9
WXYZ
. Press
to confirm the change.
If the value is greater than 255, the message “Over limit” appears. If correct, the message “Done!” appears.
Default: 30s, minimum value 15s, maximum value 255s.
3.0 CONVERSATION TIME
This is the interval of time, expressed in seconds, that the electronic unit monitors from the moment a call is answered by the indoor unit. Once the interval
has elapsed, the electronic unit disconnects the indoor unit. Enter the new time with buttons
0
+
to
9
WXYZ
(in steps of 10 seconds). Press
to confirm
the change. If the value is greater than 2550, the message “Over limit” appears. If correct, the message “Done!” appears.
Default: 120s, minimum value 10s, maximum value 2550s.
3.1 SELF-START TIME
The time, expressed in seconds, for which the electronic remains connected to an indoor unit, following activation via the self-start function. Once the interval
has elapsed, the electronic unit disconnects the indoor unit. Enter the new time with buttons
0
+
to
9
WXYZ
. Press
to confirm the change. If the value is
greater than 255, the message “Over limit” appears. If correct, the message “Done!” appears.
Default: 10s, minimum value 1s, maximum value 255s.
3.2 LOCK TIME
Activation time of the lock connected between terminals S+ / S- and +12V / SR.
Enter the new time with buttons
0
+
to
9
WXYZ
. Press
to confirm the change. If the value is greater than 255, the message “Over limit” appears. If correct,
the message “Done!” appears.
Default = 1 s, minimum value 0 s, maximum value 255 s.
3.3 FUNCTION 1 TIME
Activation time of the device connected between ter12V / F1. Enter the new time with buttons
0
+
to
9
WXYZ
. For the minimum value of 0.5 seconds.
enter
0
+
. Press
to confirm the change. If the value is greater than 255, the message “Over limit” appears. If correct, the message “Done!” appears.
Default = 1 s.
3.4 FUNCTION 2 TIME
Activation time of the device connected between ter12V / F2. Enter the new time with buttons
0
+
to
9
WXYZ
. For the minimum value of 0.5 seconds.
enter
0
+
. Press
to confirm the change. If the value is greater than 255, the message “Over limit” appears. If correct, the message “Done!” appears.
Default = 1 s.
3.5 EXTERNAL VOLUME
7KLVLVWKHYROXPHRIWKHVSHDNHUDWWDFKHGWRWKHHOHFWURQLFXQLWZKLFKFDQEHDGMXVWHGWKURXJKVWHSV3UHVV
to enable changes to the volume setting.
Press the
buttons to increase or reduce the volume. Press
to confirm the change. When the change is confirmed, the message “Done!”
will appear.
Default = 6
table 7