Step 2.
To specify ONT settings, go to the corresponding view with the help of the interface ont
command. Specify ONT serial number, password, or their combination.
LTP-8X# configure terminal
LTP-8X(config)# interface ont 0/0
LTP-8X(config)(if-ont-0/0)# serial ELTX5C00008C
LTP-8X(config)(if-ont-0/0)# password 0000000000
Step 3.
Apply the changes by using the
do commit
command.
LTP-8X(config)(if-ont-0/0)# do commit
Step 4.
OLT entry configuration has pre-defined ONT profiles which will be automatically assigned to
ONT. View the ONT configuration with the help of the do show interface ont 0/0 configuration
command.
LTP-8X(config)# do show interface ont 0/0 configuration
-----------------------------------
[ONT0/0] configuration
-----------------------------------
Description: ''
Status: UP
Serial: 0000000000000000
Password: ''
Fec up: false
Downstream broadcast: true
Ber interval: none
Ber update period: 60
Rf port state: enabled
Omci error tolerant: false
Profile shaping: shaping-00 ONT Profile Shaping 0
Profile ports: ports-00 ONT Profile Ports 0
Profile management: management-00 ONT Profile Management 0
Profile scripting: unassigned
Custom model: none
Template: unassigned
20.3.1.
Model 1
Consider configuration of a data communication channel which is based on model 1 and implements
"VLAN for Subscriber". Fig. 20.3 shows a configuration of two abstract services with subscriber C-VLAN
200 and U-VLAN 10 and 11 for each service correspondingly.
Fig. 20.3. Service Abstract Representation for Model 1