LTP-8X optical line terminal
Step 1.
Attach the terminal to the vertical guides of the rack.
Step 2.
Align mounting holes in the support bracket with the corresponding holes in the rack guides. Use
the holes of the same level on both sides of the guides to ensure the terminal horizontal installation.
Step 3.
Use a screwdriver to screw the terminal to the rack.
Fig. 7.2. Terminal Rack Installation
The terminal is horizontally ventilated. The side panels have air vents. Do not block air vents to avoid
components overheating and subsequent terminal malfunction.
To avoid overheating and provide necessary ventilation of the terminal, sufficient space
should be provided above and below the terminal, not less than 10 cm.
Power Supply Module Installation
Depending on power supply requirements, the terminal can be supplemented with either an AC power
supply module, 220 V, 50 Hz, or a DC power supply module, 48 V. The location of the power supply
module is shown in Fig. 7.3